Path: Top > Tugas Akhir - D3 > 2017 > Jurusan Teknik Elektro > Program Studi Teknik Listrik > 2019

Evaluasi Faktor Daya Listrik pada Hotel Arya Duta Bandung

Electrical Power Factor Evaluation at Arya Duta Bandung Hotel

Tugas Akhir, 001 / 2019 / TLI
Undergraduate Theses from JBPTPPOLBAN / 2020-03-19 09:46:32
Oleh : Ahmad Quaes As Sidiq - 161321001 (ahmadqiss@gmail.com)
Dibuat : 2020-03-19, dengan 4 file

Keyword : Electrical Power, Factor Evaluation,Arya Duta, Bandung Hotel
Subjek : Evaluasi Faktor, Daya Listrik,Hotel Arya, Duta Bandung

Hotel Arya Duta merupakan salah satu hotel berbintang 5 (lima) di Kota Bandung. Suatu hotel bisa dikatakan baik apabila, selain memiliki fasilitas dan pelayanan yang baik, salah satunya yaitu memiliki sistem kelistrikan yang memadai dengan pengunaan daya yang efisien, yaitu yang konsumsi listriknya sesuai dengan kebutuhan energinya. Pemborosan daya bisa terjadi apabila pemakaian daya listrik berada pada kondisi beban puncak, dan nilai dari faktor dayanya (cosâ) dibawah standar beban yang diperbolehkan PLN yaitu > 0,85. Hasil pengukuran menggunakan Power Mettrel yang dihubungkan pada LVMPD Hotel Arya Duta Bandung menunjukan nilai 0,77. Maka dilakukan perbaikan faktor daya dengan metode pemasangan kapasitor bank sebesar 25 kVAR sebanyak 5 step pada LVMDP dilengkapi dengan power factor regulator untuk menjaga nilai factor daya diatas standar yang telah ditentukan, yaitu pada nilai 0,95.

Deskripsi Alternatif :

Arya Duta Hotel is one of the 5 (five) star hotels in Bandung. A hotel can be said to be good if, in addition to having good facilities and services, one of which is to have an adequate electrical system with efficient use of power, which is electricity consumption in accordance with its energy needs. Power waste can occur if the use of electric power is at peak load conditions, and the value of the power factor (cosâ) is below the standard allowable load of PLN which is> 0.85. The results of measurements using Power Metel connected to the LVMPD Hotel Arya Duta Bandung showed a value of 0.77. Then the power factor repair is done with the method of installing a capacitor bank of 25 kVAR for 5 steps on LVMDP equipped with a power factor regulator to maintain the power factor value above a predetermined standard, which is at a value of 0.95.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakHelmi Purwanti
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorhelmi.purwanti@polban.ac.id
E-mail CKOhelmi.purwanti@polban.ac.id

Print ...

Kontributor...

  • Pembimbing 1: Ir. Abdullah Asegaf, M.T.



    Pembimbing 2: Sudrajat, B.Eng., M.Eng.Sc., Editor: Muhammad Abdillah Islamy, S.Pd