Path: Top > Tugas Akhir - D3 > 2017 > Jurusan Teknik Elektro > Program Studi Teknik Elektronika > 2020

Sistem Distribusi Air Saat Krisis Air Berbasis Mikrokontroler menggunakan SCADA

Distributed Water System While Water Crisis Condition based on Microcontroler using SCADA

Tugas Akhir, 021 / 2020 / TEL
Undergraduate Theses from JBPTPPOLBAN / 2021-03-25 10:42:54
Oleh : 171311025 - Rizky Ahmad Fauzy (rizky.ahmad.tec17@polban.ac.id)
Dibuat : 2021-03-25, dengan 4 file

Keyword : Distributed Water System, Water Crisis Condition, Microcontroler, SCADA
Subjek : Sistem Distribusi Air, Krisis Air, Mikrokontroler, SCADA

Pada saat krisis air bersih di sejumlah desa,banyaknya desa desa yang tidak mendapatkan air bersih. Namun, ada juga desa di sekitarnya yang menerima air bersih yang sangat melimpah, hal ini merupakan pendistribusian air yang sangat tidak efisien dan tidak merata. Alat ini digunakan untuk mengatur pendistribusian air pada Sumber air atau penampungan air pusat. Data jumlah volume air diambil dengan menggunakan sensor Load Cell sebagai pengukur level air yang dapat dikirim ke mikrokontroler.Pada mikrokontroler data dikalkulasikan terhadap kebutuhan galon yang akan di distribusikan menggunakan model matematika, Hal ini untuk mengetahui berapa nilai efisiensi air yang di distribusikan di setiap galon. Pada setiap tanki di desa terdapat sebuah sensor Load Cell yang terhubung ke mikrokontroler yang berfungsi sebagai umpan balik data volume air pada masing masing tanki secara Real Time. Data dikirim menggunakan jalur komunikasi serial dengan Mikrokontroler Sebagai receiver. Metoda yang digunakan dalam pembuatan alat ini menggunakan sistem SCADA,dimana operator dapat melakukan kontrol,data akuisisi,dan monitoring dari jarak jauh.

Deskripsi Alternatif :

During the water crisis in a many of villages, many of the villages did not get enough of clean water. However, there are also villages in the vicinity that receive abundant clean water. This is an uneven distribution of water. This tool is use to control distribution of water at the water sources to distributing the water for each distribution gallon. Data on the amount of water volume is taken using the Load Cell sensor as a measure of the water level that can be sent to the microcontroller. In the microcontroller the data is calculated on the number of gallons that will be distributed using a mathematical model, this is to see how much water efficiency value is distributed in each gallon. In each tank in the gallon, there is a Load Cell sensor connected to the microcontroller which functions as a real time feedback for water volume data in each tank. Data is sent using a serial communication line with microcontroller as a receiver. The method used in the manufacture of this tool uses the SCADA system, where the operator can perform remote control, data acquisition and monitoring.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakHelmi Purwanti
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorhelmi.purwanti@polban.ac.id
E-mail CKOhelmi.purwanti@polban.ac.id

Print ...

Kontributor...

  • Pembimbing 1: Robinsar Parlindungan, S.Si., M.T.


    Pembimbing 2: Dodi Budiman Margana, S.T., M.T., Editor: Muhammad Abdillah Islamy, S.Pd