Rancang Bangun Sistem Refrigerasi Mini Freezer Dan Pengujian Performansi Akibat Variasi Jarak Condensing Unit Terhadap Dinding

Design Of Mini Freezer Refrigeration System And Performance Testing Variation Of The Condensing Unit Position To The Wall

Tugas Akhir, 030 / 2018 / RTU
Undergraduate Theses from JBPTPPOLBAN / 2019-01-21 14:31:19
Oleh : Agus Ardiansyah - 151611034
Dibuat : 2019-01-21, dengan 4 file

Keyword : Condensing Unit, efisiensi, COP, chilling time
Subjek : Condensing Unit, efficiency, COP, chilling time

Sistem refrigerasi sangat dibutuhkan dalam kehidupan manusia, semakin terbatasnya ruang kosong yang tersedia membuat kita kesulitan untuk menginstalasi sistem tersebut, sehingga harus diperhitungkan kembali apabila ingin menginstalasi sistem tersebut, hal ini membuat perancang sistem refrigerasi harus sangat teliti untuk membuat sebuah sistem yang sesuai dengan keadaan saat ini. Tujuan dari penelitian tugas akhir ini yaitu melakukan perbandingan pengaruh variasi jarak condensing unit terhadap dinding pada sistem mini freezer dengan mempertimbangkan dampak dari perubahan jarak condensing unit yang bisa mempengaruhi hasil dari sistem itu sendiri seperti berdampak pada COP dan efisiensi sistem, maka akan didapat hasil COP dan efisiensi yang lebih tinggi, sehingga dilakukan beberapa perbedaan dalam peletakan condensing unit terhadap dinding dengan jarak yang ditentukan yaitu 5cm, 10cm, 20cm, dan 30cm. Dalam data yang telah diolah didapatkan dari hasil variasi jarak condensing unit yaitu 5cm, 10cm, 20cm, dan 30cm berturut-turut adalah 3.94, 4.48, 4.53, 5.22 juga didapat hasil efisiensinya 78%, 82%, 87%, dan 91% dengan chilling time 20, 15, dan 10 menit, hal ini menunjukan peningkatan dari data rancangan yaitu dari segi efisiensi yang melebihi data rancangan 75% dan chilling time rancangan yang sangat cepat yaitu 30 menit, sementara nilai COP sudah hampir mendekati COP rancangan yaitu 5.24. Kata Kunci: Condensing Unit, efisiensi, COP, chilling time.

Deskripsi Alternatif :

Refrigeration system is necessary to human life, the limited available available space makes it difficult for us to install the system, so it must be recalculated if you want to install the system, this makes the system designer refrigeration need to think again to make a system that are now in accordance with .The purpose of the end of this research is to do the influence the variation condensing unit against a wall on that mini freezer by considering the impact of the changes condensing unit that affects the bottom of the system itself as an impact on COP and efficiency of the system. So to be acquired the COP and efficiency higher , so done several differences in laying condensing unit against the wall and the term 5cm, 10cm, 20cm, and 30cm. The data that has been processed is obtained from the variation of the condensing unit distance of 5cm, 10cm, 20cm, and 30cm, successive is 3.94, 4.48, 4.53, 5.22 also obtained the results of efficiency 78 %, 82 %, 87 %, and 91 % with chilling time 20, 15, and 10 minutes, this shows an improvement from the design data, that is in terms of efficiency that exceeds data design 75 % and chilling time design very faster which 30 minutes, while the COP value is close to the COP design of 5.24. Keywords: Condensing Unit, efficiency, COP, chilling time.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakHelmi Purwanti
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorhelmi.purwanti@polban.ac.id
E-mail CKOhelmi.purwanti@polban.ac.id

Print ...

Kontributor...

  • Pembimbing 1: Triaji Pangripto Pramudantoro, S.T., M.Eng.

    Pembimbing 2: Markus, S.T., M.T., Editor: Erlin Arvelina

Download...