Analisis Perpindahan Kalor Konveksi Paksa Aliran Turbulen Di Atas Plat-Rata Menggunakan AC Presisi Merk TATUNG Model TSC-5EL

Forced Convection Heat Analisys of Turbulent Flow on Flat-Plate Using TATUNG Precision Air Conditioner Model TSC-5EL

Tugas Akhir, 047 / 2013 / RTU
Undergraduate Theses from JBPTPPOLBAN / 2017-04-17 12:35:35
By : Alisa Shalehatuz Zakia - 101611035 (alisa.zakia@live.com)
Created : 2017-04-17, with 4 files

Keyword : AC presisi, perpindahan kalor, aliran turbulen, plat-rata
Subject : precision air conditioner, heat transfer, turbulent flow, flat-plate

Ruang server membutuhkan alat pengkondisi udara dengan ketepatan pendinginan yang tinggi (presisi). Maka dikembangkanlah Precision Air Conditioner (PAC) yang dapat menghasilkan pendinginan yang tidak kurang dan tidak lebih dari 1⁰C dari temperatur setting-nya. Dalam proses pendinginan di ruang server, peran PAC ini adalah untuk menjaga temperatur komponen elektronik yang melepaskan kalor ke udara. Sebuah AC Presisi Merk TATUNG Model TSC-5EL telah diuji seberapa besar kemampuannya untuk mendinginkan ruang server. Pengujian ini dilakukan dengan cara mendinginkan plat-rata yang telah dipanaskan oleh heater. Plat-rata ini merepresentasikan lemari-lemari komponen elektronik yang ada di ruang server. AC Presisi ini dapat menghasilkan udara dengan tipe aliran turbulen. Dengan perpindahan panas persatuan lebar rata-rata adalah 59,596 W/m. Kata Kunci: AC presisi, perpindahan kalor, aliran turbulen, plat-rata.

Description Alternative :

Server room requires an air conditioning system with high cooling accuracy (precision). Thus, Precision Air Conditioner (PAC) is used that can produce cooling with a temperature different ±1⁰C. In server room, the role of Precision Air Conditioner is to keep the temperature of electronic components which release heat to the air. A TATUNG Precision Air Conditioner Model TSC-5EL has been tested the ability to cool the server room. The testing is done by cooling a flat-plate that has been heated by a heater. The flat-plate represents the cabinets of electronic components that exist in the server room. This Precision Air Conditioner can produce turbulent flow of air flow with heat transfer per width is 59,596 W/m average. Keywords: precision air conditioner, heat transfer, turbulent flow, flat-plate.

Give Comment ?#(0) | Bookmark

PropertyValue
Publisher IDJBPTPPOLBAN
Organization
Contact NameHelmi Purwanti
AddressJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
CityBandung
RegionJawa Barat
CountryIndonesia
Phone022 201 3789 ext. 168, 169, 239
Fax022 201 3889
Administrator E-mailhelmi.purwanti@polban.ac.id
CKO E-mailhelmi.purwanti@polban.ac.id

Print ...

Contributor...

  • Pembimbing 1: Ade Suryatman Margana, S.T., M.Eng.

    Pembimbing 2: Luga Martin Simbolon, S.T., M.Sc., Editor: Erlin Arvelina

Downnload...