Path: Top > Tugas Akhir - D3 > 2017 > Jurusan Teknik Elektro > Program Studi Teknik Listrik > 2018
Pengembangan Simulator Jaringan Distribusi Untuk Pengukuran Dan Proteksi Gangguan Hubung Singkat
Developing Distribusion Network Simulator As Short Circuit Protection Measurement
Tugas Akhir, 032 / 2018 / TLIUndergraduate Theses from JBPTPPOLBAN / 2019-05-20 13:40:22
Oleh : Andrian Dwi Handoko - 151321034 (andrianhandoko97@gmail.com)
Dibuat : 2019-05-20, dengan 4 file
Keyword : Gangguan hubung singkat, Pengukuran, MCGG 82
Subjek : Short Circuit, Measurement, MCGG 82
Gangguan yang sering terjadi pada sistem distribusi yaitu gangguan hubung singkat, yang dapat menimbulkan kerusakan pada peralatan distribusi maupun beban-beban listrik. Salah satu perangkat untuk mencegah terjadinya gangguan tersebut adalah relai arus lebih. Relai arus lebih bisa mendeteksi adanya gangguan yang terjadi pada daerah pengamannya dan memberi peritah kepada pemutus tenaga untuk memisahkan bagian dari sistem pada daerah yang terganggu. Dalam proyek akhir ini akan mengembangkan simulator jaringan distribusi untuk pengukuran dan proteksi gangguan hubung singkat. Modul ini dapat memproteksi dan mengukur kondisi hubung singkat 1 fasa, hubung singkat 2 fasa, hubung singkat 3 fasa di simulator jaringan distribusi. Dalam hal ini perlu adanya peranan pengukuran meter listrik seperti volt meter dan ampere meter yang lebih kompleks dan mudah dalam penggunaannya sehingga dapat digunakan untuk melakukan beberapa pengukuran dalam satu waktu, modul ini bisa mendeteksi dan membaca adanya ganguan hubung singkat dengan cepat agar dapat mengurangi resiko kerusakan akibat gangguan hubung singkat. Pengaman yang digunakan yaitu relai MCGG 82 dan pengukuran menggunakan VAF-39A. Modul ini dipandang perlu untuk melengkapi modul-modul praktikum distribusi dan proteksi sistem tenaga yang telah ada. Penggunaan modul ini diharapkan memberi pembelajaran ketika terjadi gangguan hubung singkat pada sistem tenaga. Kata Kunci: Gangguan hubung singkat, Pengukuran, MCGG 82.
Deskripsi Alternatif :The reliability of power distribution systems is easily affected by disturbance. The disturbances frequently happened are a short circuit, which can cause damage to the distribution equipment or electrical loads. One of the devices to prevent the occurrence of the disturbance is more current relays. It can detect any disturbance occurring in their security area and give a break to the power breaker to separate parts of the system in the affected area. This final project will design the build of measurement module and short circuit protection in distribution network simulator. This module can protect and measure short circuit 1 phase, short circuit 2 phase, 3 phase short circuit in the distribution network. In this case, the need for the role of measurement of electricity meters such as Voltmeters and Amperemeters are more complex and easy to use, so that, it can be used to perform multiple measurements at one time. This module can detect and read the existence of disturbance short circuit in order to reduce the risk of damage in the event of a short circuit. The safety used is the MCGG 82 relay. The module is deemed necessary to supplement the existing practicum modules distribution and power system protection. The use of this module is expected to provide learning when a short circuit occurs in the power system. Kata Kunci: Short Circuit, Measurement, MCGG 82.
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | JBPTPPOLBAN |
Organisasi | |
Nama Kontak | Helmi Purwanti |
Alamat | Jl. Trsn. Gegerkalong Hilir Ds. Ciwaruga |
Kota | Bandung |
Daerah | Jawa Barat |
Negara | Indonesia |
Telepon | 022 201 3789 ext. 168, 169, 239 |
Fax | 022 201 3889 |
E-mail Administrator | helmi.purwanti@polban.ac.id |
E-mail CKO | helmi.purwanti@polban.ac.id |
Print ...
Kontributor...
- Pembimbing 1: Supriyanto, S.T., M.T.
Pembimbing 2: Yudi Prana Hikmat, S.T., M.T., Editor: Erlin Arvelina
Download...
File : KELENGKAPAN TA - 151321034.pdf
(614014 bytes)
File : BAB 1 - 151321034.pdf
(209631 bytes)
File : BAB 2 - 151321034.pdf
(533392 bytes)
File : BAB 5 - 151321034.pdf
(206268 bytes)