Desain Fondasi Bored Pile Tower T.91 SUTT 150 kV Tayan-Sanggau Kalimantan Barat

Bored Pile Foundation Design of T.91 Tower SUTT 150 kV Tayan-Sanggau West Kalimantan

Tugas Akhir, 020 / 2021 / KSI
Undergraduate Theses from JBPTPPOLBAN / 2022-06-13 10:54:46
Oleh : Arief Delfian Hernandi - 181111038 & Nurul Parida - 181111055 (arief.delfian.tkgd18@polban.ac.id )
Dibuat : 2022-06-13, dengan 4 file

Keyword : Bore pile, Cone Penetration Test (CPT), slope stability, pile cap
Subjek : Bore pile, Cone Penetration Test (CPT), kestabilan lereng, pile cap

Pada pengerjaan tugas akhir ini, proyek yang ditinjau adalah menara transmisi tower T.91 SUTT 150 kV yang berlokasi di Tayan – Sanggau, Kalimantan Barat. Perencanaan pekerjaan fondasi tower ini menggunakan jenis fondasi bore pile. Digunakannya fondasi bore pile dikarenakan kedalaman tanah keras yang berada pada kedalaman 8 meter. Selain itu fondasi bore pile juga diharapkan dapat memperkuat struktur di atasnya, selain itu fondasi jenis ini juga dapat menahan beban aksial tarik dan tekan serta beban lateral pada menara. Dalam perhitungan desain fondasi ini digunakan data sekunder berupa hasil beban pada tower yang telah diberikan oleh pihak kontraktor. Perencanaan fondasi tower ini dilakukan dengan menghitung daya dukung berdasarkan hasil penyelidikan tanah Cone Penetration Test (CPT) atau Sondir. Perhitungan daya dukung aksial dengan menggunakan metode Meyerhoff, perhitungan daya dukung lateral menggunakan metode Broms, perhitungan efisiensi grup menurut Converse – Labarre, perhitungan penurunan tiang kelompok menggunakan metode Vesic (1997), perhitungan kontrol geser pons, perhitungan penulangan pile cap, dan perhitungan tulangan bore pile. Mengingat lokasi yang menjadi topik dalam pengerjaan tugas akhir ini berada pada daerah perbukitan, maka harus dilakukan analisa kestabilan lereng untuk mengontrol apakah fondasi yang telah didesain aman didirikan pada lokasi tersebut. Analisa dilakukan dengan menggunakan alat bantu Geoslope/W Geostudio 2012. Dari perhitungan yang dilakukan dengan fondasi bore pile diameter 0,4 m dan panjang tiang 6 m, didapat jumlah tiang pada satu kelompok yaitu 9 tiang. Dimensi pile cap dari hasil perencanaan adalah 3200 mm × 3200 mm. Tulangan atas dan bawah pile cap untuk arah x adalah 26D19-120 mm dan untuk arah y 26D19-120 mm. Tulangan utama bore pile yang digunakan adalah 12D-19 dan tulangan sengkang D12-250 mm. Lalu dari hasil analisa kestabilan lereng setelah adanya fondasi menghasilkan angka keamanan atau SF > 1,5, maka lereng dinyatakan aman.

Deskripsi Alternatif :

In this final project, the project being reviewed is the transmission line tower T.91 SUTT kV located in Tayan – Sanggau, West Kalimantan. The planning of this tower foundation work uses the type of bore pile foundation. The use of bore pile foundation is due to the depth of hard soil which is at a depth of 8 meters. In addition, the bore pile foundation is also expected to strengthen the structure above it, besides that this type of foundation can also withstand tensile and compressive axial loads as well as lateral load on the tower. In calculating this foundation design, secondary data is used in the form of load on the tower that has been given by the contractor. The planning of the tower foundation is carried out by calculating the carrying capacity based on the results of the Cone Penetration Test (CPT) or Sondir soil investigation. Calculation of axial bearing capacity using the Meyerhoff method, calculation of lateral bearing capacity using the Broms method, calculation of group pile settlement using the Vesic method (1997), calculation of punch shear control, calculation of pile cap reinforcement, and calculation of bore pile reinforcement. In addition, slope stability analysis is also carried out to control whether the foundation that has been designed is safe to be erected at that location. The analysis was carried out using the tool Geoslope/W Geostudio 2012. From the calculations carried out with a bore pile foundation with a diameter of 0,4 m and a pile length 0f 6 m, the numbers of piles in one group are 9 piles. Pile cap dimensions from the planning results are 3200 mm × 3200 mm. The top and bottom pile cap reinforcement for the x direction is 26D19-120 mm and for the direction it is 26D19-120 mm. The main bore pile reinforcement used is 12D-19 and D12-250 mm stirrup reinforcement. Then the results of the slope stability analysis after the foundation produces a safety number or SF > 1,5, then the slope is declared safe.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakErlin Arvelina
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorerlin.arvelina@polban.ac.id
E-mail CKOerlin.arvelina@polban.ac.id

Print ...

Kontributor...

  • Pembimbing 1: Ir. Geni Firuliadhim, M.T.


    Pembimbing 2: Aditia Febriansya, S.ST., M.Tr.T., Editor: Muhammad Abdillah Islamy, S.Pd

Download...