Cool-Box merupakan mesin sistem refrigerasi kompresi uap yang digunakan untuk mendinginkan atau membekukan produk makanan ataupun minuman yang penggunaannya semakin banyak dijumpai saat ini. Penggunaan refrigeran CFC atau HCFC mengakibatkan beberapa dampak negatif dari penggunaan mesin cool-box, diantaranya tidak ramah lingkungan dan tidak hemat energi listrik. Tujuan penelitian pada tugas akhir ini adalah untuk menganalisis dan membandingkan performansi suatu sistem refrigerasi cool-box yang mampu menghemat konsumsi energi dan ramah lingkungan. Metoda penelitian ini dilakukan pertama menggunakan R-22 sebagai refrigeran primernya dan selanjutnya dilakukan proses retrofitting dengan menggunakan R-290 dan penambahan refrigeran sekunder berupa campuran air dengan propylene glycol (80% air dan 20% propylene glycol). Selanjutnya analisis dilakukan berdasarkan data dari setiap titik-titik pengukuran seperti tekanan suction, tekanan discharge, temperatur suction, temperatur discharge, temperatur keluar kondenser, temperatur kabin, arus listrik, tegangan, dan energi listrik. Dari hasil analisis diperoleh suatu sistem refrigerasi cool-box yang paling baik adalah sistem yang menggunakan R-290 yang dilengkapi dengan propylene glycol konsentrasi 20% dengan nilai COP aktual 3.64, COP Carnot 4.91,dan nilai efisiensi72.58%, sedangkan nilai penghematan energi listrik sekitar 94.4% lebih hemat dibanding mesin R-22 dan R-290 tanpa refrigeran sekunder. Kata kunci: cool-box, R-22, R-290, retrofitting, refrigeran sekunder, efesiensi.

Description Alternative :

Cool-Box is the engine vapor compression refrigeration system which is used to cool or freeze food products or beverages that its use increasingly prevalent nowadays. The uses of CFC or HCFC refrigerants give some negative effects on the use of the cool-box machine, such as not environment-friendly and not energy efficient. The purposes of this final project reasearch is to analyze and compare the performance of cool-box refrigeration system that reduce energy consumption and environment-friendly. The first method of this research is performed using R-22 as the primary refrigerant and the second will be done form retrofitting process using R-290 and addition of secondary refrigerant mixtures of water with propylene glycol (80% water and 20% propylene glycol). Further analyzes were conducted based on data from each of measurement points such as pressure suction, discharge pressure, suction temperature, discharge temperature, out condenser temperature, cabin temperature, electric current, voltage, and electrical energy. From the results obtained by the analysis of a refrigeration system cool-box is the best system that uses R-290 with propylene glycol concentrations of 20% with the actual COP value 3.64, COP Carnot value 4.91, and the value efficiency 72.58%, while the value of electrical energy savings about 94.4% more efficient than R-22 engine and R-290 engine without secondary refrigerant. Keywords: cool-box, R-22, R-290, retrofitting, secondary refrigerant, efficiency.

Give Comment ?#(0) | Bookmark

PropertyValue
Publisher IDJBPTPPOLBAN
Organization
Contact NameHelmi Purwanti
AddressJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
CityBandung
RegionJawa Barat
CountryIndonesia
Phone022 201 3789 ext. 168, 169, 239
Fax022 201 3889
Administrator E-mailhelmi.purwanti@polban.ac.id
CKO E-mailhelmi.purwanti@polban.ac.id

Print ...

Contributor...

  • Pembimbing 1: Triaji Pangripto Pramudantoro, S.T., M.Eng.

    Pembimbing 2: Cecep Sunardi, S.T., M.Eng., Editor: Erlin Arvelina

Downnload...