Perancangan Struktur Bawah Gedung Parkir Pada Tanah Lunak

The Design of Substructure Parking Building on The Soft Soil

Skripsi, 006 / 2021 / TPPG
Undergraduate Theses from JBPTPPOLBAN / 2022-09-23 13:21:35
Oleh : Aulia Maghfira Putri - 171144006 & Riksa Maulana Koswara - 171144026 (riksa.maulana.tppg17@polban.ac.id)
Dibuat : 2022-09-23, dengan 4 file

Keyword : basement, dinding penahan tanah, diaphragm wall, fondasi, tanah lunak, ground anchor, bottom up
Subjek : basement, retaining wall, diaphragm wall, foundation, soft soil, ground anchor, bottom up

Pemenuhan sarana ruang parkir kendaraan semakin bertambah seiring dengan bertambahnya jumlah kendaraan. Hal tersebut bisa terjadi karena terbatasnya lahan untuk pembangunan serta semakin tingginya harga beli lahan. Maka dari itu, pembangunan ke arah vertikal adalah sebuah solusi dalam rangka efektivitas penggunaan lahan. Pembangunan basement sangat dipengaruhi oleh kondisi aktual tanah di lapangan. Dalam pelaksanaannya, maka diperlukan sebuah analisis kestabilan galian dan diaphragm wall menggunakan metode trial and error pada software PLAXIS 2D dengan memperhatikan perilaku pada diaphragm wall sesuai dengan SNI 8460:2017. Sedangkan hasil pemodelan pada aplikasi ETABS V.2016 berupa beban yang harus ditahan oleh fondasi dan berguna untuk perancangan fondasi dan pile cap. Hasil analisis yang didapatkan pada saat pembangunan struktur dinding penahan tanah berupa diaphragm wall memerlukan alternatif perkuatan berupa ground anchor. Hasil analisis yang didapatkan berupa dimensi balok, kolom, pelat lantai, tie beam, dan pelat lantai terbawah pada struktur basement, fondasi yang akan dibangun berupa fondasi tiang pancang berdiameter 600 mm dengan kedalaman 26 m yang digabungkan kedalam tiga tipe pile cap, struktur diaphragm wall memerlukan alternatif perkuatan berupa ground anchor dan adanya balok pengikat berupa baja WF untuk mengikat antar panel diaphragm wall dan ground anchor.

Deskripsi Alternatif :

The fulfillment of parking space is increasing along with the increasing number of vehicles. This happens because of the limited land for development and the higher price of land. Therefore, vertical development is an effective solution for the land use. In practice, the basement construction of is greatly influenced by the actual conditions of the land soil. Thus, it is necessary to analyze the excavation stability and the diaphragm wall. It was carried out using the trial and error method in the PLAXIS 2D software by paying attention to the behavior of the diaphragm wall in accordance with SNI 8460:2017. Whereas, the modeling results in the ETABS V.2016 application are in the form of loads that must be held by the foundation and are useful for designing foundations and pile caps. The results of the analysis obtained during the construction of the retaining wall structure in the form of a diaphragm wall require alternative reinforcement in the form of a ground anchor. The results of the analysis obtained are the dimensions of beams, columns, floor slabs, tie beam, and lowest floor slabs in the basement structure, the foundation to be built is a pile foundation with a diameter of 600 mm with a depth of 26 m which combined by 3 type of pile caps, the diaphragm wall structure requires alternative reinforcement in the form of ground anchors, and waller beam which the WF steel material for binding panel of diaphragm wall with ground anchor.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakErlin Arvelina
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorerlin.arvelina@polban.ac.id
E-mail CKOerlin.arvelina@polban.ac.id

Print ...

Kontributor...

  • Pembimbing 1: Andri Krisnandi, S.ST., M.Eng.

    Pembimbing 2: Ambar Susanto, S.T.Si., M.T., Editor: Erlin Arvelina

Download...