Pengaruh Pembebanan Transformator Terhadap Efektifitas Pendinginan Transformator Di Gardu G PT PLN (Persero) Distribusi Jawa Barat Area Garut

The Influence Of Electrical Transformer Load To Its Coolant Effectiveness At G Substation PT PLN (Persero) West Java Distribution Garut Area

Tugas Akhir, 004 / 2018 / TEN
Undergraduate Theses from JBPTPPOLBAN / 2018-09-06 12:18:49
Oleh : Ayuni - 151711005 (ayuni.tken15@polban.ac.id)
Dibuat : 2018-09-06, dengan 4 file

Keyword : Transformator, Belitan Transformator, Minyak Transformator
Subjek : Transformer, Transformer coil, Transformer Oil

Energi listrik disalurkan ke konsumen agar dapat dimanfaatkan untuk berbagai keperluan seperti hal nya di Area Garut. Kebutuhan listrik di Area Garut sendiri semakin bertambah tiap harinya, berdasarkan data formula jogja kebutuhan listrik di Area Garut pada Bulan Januari 2017 yaitu sebesar 62,170,955 kWh. Peralatan yang berperan penting dalam penyaluaran tenaga listrik ini salah satunya yaitu transformator. Setiap transformator mengalami beberapa kerugian yang didisipasikan dalam bentuk panas. Kerugian yang paling besar yang menjadi sumber utama penghasil panas pada transformator yaitu terjadi di kumparan (belitan) dan inti. Panas pada transformator jika tidak didinginkan dengan benar akan mengakibatkan suhu transformator naik terus menerus yang mana dapat menyebabkan isolasi belitan menjadi kering dan rusak. Minyak transformator sebagai bekerja sebagai pendingin dan menerima seluruh panas dari belitan dan inti. Minyak panas pada transformator ini kemudian bersirkulasi dan memindahkan panasnya ke lingkungan melalui kerangka (case) transformator. Kenaikan suhu maksimum belitan berdasarkan SPLN 50; 1997 hanya diperbolehkan sampai 55 oC, sedangkan Kenaikan suhu maksimum minyak berdasarkan SPLN 50; 1997 hanya diperbolehkan sampai 50 oC. Kata kunci: Transformator, Belitan Transformator, Minyak Transformator.

Deskripsi Alternatif :

Electrical energy is channeled to consumers so that it can be used for various purposes such as the Garut Area. Electricity needs in Garut area itself are increasing every day, based on data from Jogja formula, the electricity needs in Garut Area in January 2017 are 62,170,955 kWh. The equipment that plays an important role in the transmission of electricity is one of them is a transformer. Each transformer experiences some losses that are dissipated in the form of heat. The biggest loss is the main source of heat in the transformer which occurs in the coil (winding) and core. The heat on the transformer if it is not cooled properly will cause the transformer temperature to rise continuously which can cause the insulation of the windings to become dry and damaged. Transformer oil as working as a cooler and receiving all the heat from the windings and core. The hot oil in the transformer then circulates and transfers heat to the environment through a transformer case (case). Maximum winding temperature rise based on SPLN 50; 1997 was only allowed up to 55 oC, while the maximum temperature rise was based on SPLN 50; 1997 is only allowed up to 50 oC. Keywords: Transformer, Transformer coil, Transformer Oil.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakHelmi Purwanti
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorhelmi.purwanti@polban.ac.id
E-mail CKOhelmi.purwanti@polban.ac.id

Print ...

Kontributor...

  • Pembimbing: Ir. Conny K. Wachjoe, M.Eng., Ph.D., Editor: Erlin Arvelina

Download...