Analisis Kinerja Cooling Tower Unit 2 dan Unit 3 Tahun 2016 di PT. Indonesia Power UPJP Kamojang

The Analysis of The 2nd and 3rd Units Cooling Tower Performance on 2016 at PT. Indonesia Power UPJP Kamojang

Tugas Akhir, 008 / 2020 / RTU
Undergraduate Theses from JBPTPPOLBAN / 2021-12-02 14:05:01
Oleh : Bela Azahra - 171611007 (bela.azahra.tptu17@polban.ac.id)
Dibuat : 2021-12-02, dengan 4 file

Keyword : Analysis, Performance, Cooling Tower, PT. Indonesia Power, UPJP Kamojan
Subjek : Analisis Kinerja, Cooling Tower, Unit 2, Unit 3, PT. Indonesia Power, UPJP Kamojang

Cooling Tower banyak menggunakan sistem refrigerasi dalam proses produksinya, salah satunya adalah cooling tower yang digunakan untuk sirkulasi air pendingin untuk mendinginkan air hasil kondensasi. Untuk mengetahui Kinerja cooling tower yang dimiliki oleh PT. Indonesia Power UPJP Kamojang maka diperlukan pengukuran kinerja, seperti temperatur udara bola basah, suhu air masuk, suhu air keluar dan juga debit air yang mengalir. Data yang digunakan diambil dari tanggal 10 Januari 2016 dengan perbandingan unit yang berbeda. Hasil dari analisis data didapatkan bahwa, rata-rata nilai range untuk unit 2 sebesar 20,08°C dan untuk unit 3 sebesar 19,25°C, kemudian rata-rata nilai approach untuk unit 2 sebesar 14,12â°C dan untuk unit 3 sebesar 10,54°C, dan rata- rata nilai untuk kinerja cooling tower unit 2 sebesar 59% sedangkan untuk unit 3 sebesaar 65%.

Deskripsi Alternatif :

Cooling tower uses a lot of refrigeration system in the production process, one of them is a coling tower which is used to circulate cooling water to cool the condensed water. To find out the performance of the cooling tower owned by PT. Indonesia Power UPJP Kamojang, it is necessary to measure the effectiveness, as temperature wetbulb, temperature water inlet, temperature water outlet and also flow rate of water. The data used were taken from 10 January 2016 with a comparison of different unit. The result of the data analysis show that, the average value of range for unit 2 is 20.08°C and for unit 3 is 19.25°C, then the average of approach value for unit 2 is 14.12°C and for unit 3 is 10.54°C, and the average value for cooling tower unit 2 performance is 59% while for unit 3 is 65%.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakErlin Arvelina
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorerlin.arvelina@polban.ac.id
E-mail CKOerlin.arvelina@polban.ac.id

Print ...

Kontributor...

  • Pembimbing 1: Ir. Sumeru, M.T., Ph.D.




    Pembimbing 2: Drs. Ismail Wellid, M.T., Editor: Muhammad Abdillah Islamy, S.Pd

Download...