Analisis Perbandingan Performansi Sistem Refrigerasi Pada Ice Bank Dengan Menggunakan Air Terhadap Larutan Sodium Klorida Sebagai Refrigeran Sekunder
Comparative Analysis Performance Of Ice Bank Refrigeration System Using Water Toward Sodium Chloride Solution As Secondary Refrigerant
Skripsi, 009 / 2018 / PTUUndergraduate Theses from JBPTPPOLBAN / 2019-01-10 10:40:23
Oleh : Eka Ambarwati Nurjanah - 141624010 (ekaambar13@gmail.com)
Dibuat : 2019-01-10, dengan 4 file
Keyword : Ice Bank, Air, Larutan Sodium klorida, Δt, Kapasitas Pendinginan, Daya listrik, Efisiensi
Subjek : Ice Bank, Water, Sodium Chloride Solution, Δt, Cooling Capacity, Power Consumption, Efficiency
Sistem refrigerasi pada ice bank merupakan salah satu pengaplikasian dari sistem refrigerasi dengan refrigeran sekunder sebagai media penukar kalor untuk produk yang didinginkan. Dimana refrigeran sekunder yang terdapat di dalam thermal storage di turunkan temperaturnya hingga sebagian refrigeran sekunder berubah fasa menjadi es. Analisis yang dilakukan adalah untuk mengetahui kinerja sistem dengan membandingkan penggunaan refrigeran sekunder yaitu air dan larutan sodium klorida. Metode yang digunakan adalah melalui proses pengambilan data, pengolahan dan analisis data yang didapat. Dari hasil perhitungan dan analisis pada sistem ice bank ketika sistem menggunakan air lebih baik dibandingkan pada saat sistem mengunakan larutan sodium klorida. Dapat dibuktikan dengan nilai rata-rata dari Δtin-out koil evaporator adalah 2,268⁰C, kapasitas pendinginan refrigeran sekunder adalah 367,99 Watt dan jumlah konsumsi daya listrik yang digunakan selama sistem bekerja adalah 2,292 kWh. Saat sistem menggunakan larutan sodium klorida, nilai rata-rata dari Δtin-out koil evaporator adalah 2,501⁰C, kapasitas pendinginan refrigeran sekunder adalah 315,03 Watt, serta jumlah konsumsi daya listrik yang digunakan selama sistem bekerja adalah 2,33 kWh. Nilai efisiensi rata-rata yang didapatkan pada saat sistem menggunakan air sebagai refrigeran sekunder adalah 40,45% sedangkan saat menggunakan larutan sodium klorida efisiensinya adalah 41,35%. Kata Kunci: Ice Bank, Air, Larutan Sodium klorida, Δt, Kapasitas Pendinginan, Daya listrik, Efisiensi.
Deskripsi Alternatif :Refrigeration system in ice bank is one application of refrigeration system with secondary refrigerant as medium heat exchanger for refrigerated product. Where the secondary refrigerant contained in the thermal storage decreases in temperature until some of the secondary refrigerant changes the phase to ice. The analysis is to know the performance of the system by comparing the use of secondary refrigerant that is water and sodium chloride solution. The method used is through the process of data retrieval, processing and analysis of data obtained. From the calculation and analysis on the ice bank system when the system uses water better than when the system using sodium chloride solution. Can be proved by the average value of Δtin-out coil evaporator is 2,268⁰C, the secondary refrigerant refrigeration capacity is 367,99 Watts and the amount of power consumption used during the working system is 2,292 kWh. When the system uses sodium chloride solution, the mean value of Δtin-out evaporator coil is 2,501⁰C, the refrigerant's secondary cooling capacity is 315,03 Watts, and the amount of power consumption used during the working system is 2,33 kWh. The average efficiency value obtained when the system using water as the secondary refrigerant is 40,45%, while using sodium chloride solution efficiency is 41,35% Keywords: Ice Bank, Water, Sodium Chloride Solution, Δt, Cooling Capacity, Power Consumption, Efficiency.
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | JBPTPPOLBAN |
Organisasi | |
Nama Kontak | Helmi Purwanti |
Alamat | Jl. Trsn. Gegerkalong Hilir Ds. Ciwaruga |
Kota | Bandung |
Daerah | Jawa Barat |
Negara | Indonesia |
Telepon | 022 201 3789 ext. 168, 169, 239 |
Fax | 022 201 3889 |
E-mail Administrator | helmi.purwanti@polban.ac.id |
E-mail CKO | helmi.purwanti@polban.ac.id |
Print ...
Kontributor...
- Pembimbing 1: Triaji Pangripto Pramudantoro, S.T., M.Eng.
Pembimbing 2: Ir. Arda Rahardja Lukitobudi, M.Eng., Editor: Erlin Arvelina
Download...
File : KELENGKAPAN SKRIPSI - 141624010.pdf
(643401 bytes)
File : BAB 1 - 141624010.pdf
(252759 bytes)
File : BAB 2 - 141624010.pdf
(600528 bytes)
File : BAB 5 - 141624010.pdf
(209935 bytes)