Peningkatan Kinerja Pengkondisi Udara Menggunakan R410A dengan Air Kondensat sebagai Pendingin Discharge Kompresor

Improvement Of Air Conditioning Performance Using R410A With Water Condensation As Discharge Compressor

Skripsi, 011 / 2018 / PTU
Undergraduate Theses from JBPTPPOLBAN / 2019-01-10 11:04:18
By : Elza Alfiana Putri - 141624012 (elzaalfiana.putri@yahoo.com)
Created : 2019-01-10, with 4 files

Keyword : R410A, air kondensat, pendingin, kondensor
Subject : R410A, water condensation, discharge condenser

Penkondisi udara tipe split (AC-split) banyak digunakan pada gedung komersial dan residential. Menurut hasil penelitian disebutkan bahwa sistem pengkondisi udara dapat mengkonsumsi lebih dari 50% dari total konsumsi energi pada sebuah gedung. Penelitian lain menyebutkan bahwa peningkatan performansi sistem pengkondisi udara dapat menghasilkan penghematan daya secara signifikan. Salah satu cara untuk meningkatkan performansi adalah menambahkan heat exchanger di saluran discharge dengan memanfaatkan air kondensat sebagai media pendingin suhu discharge. Metode ini selain akan menurunkan suhu discharge juga akan melepas kalor sistem sebelum dibuat melalui discharge kompresor. Keadaan ini akan menyebabkan terjadinya subcooling akibat panas yang dibuang kondenser semakin menurun dan dimensi kondenser tidak berubah. Terjadinya subcooling ini akan menyebabkan terjadinya peningkatan cop. Pemanfaatan air kondensat tersebut diaplikasikan pada AC-split untuk diuji dan diteliti apakah dapat meningkatkan koefisien performansi (Coefficient of Performance / COP) sistem sehingga dapat menyebabkan penghematan konsumsi daya. Penghematan konsumsi daya listrik sekitar 3-5 % antara yang menggunakan dan tidak menggunakan heat exchanger. Sedangkan pada COP terdapat kenaikan presentase sebesar 3-6 %. Kata kunci: R410A, air kondensat, discharge kondensor.

Description Alternative :

Split air conditioners (AC-split) are widely used in commercial and residential buildings. According to research results mentioned that the air conditioning system can consume more than 50% of the total energy consumption in a building. Other studies have suggested that improving the performance of air conditioning systems can result in significant power savings. One way to improve performance is to add heat exchangers in the discharge channel by utilizing condensate water as a cooling medium for discharge temperature. This method in addition to lowering the discharge temperature will also release the heat of the system before it is made through the compressor discharge. This situation will cause subcooling due to the heat that condenser discharges decreases and the condenser dimension does not change. The occurrence of this subcooling will lead to an increase in cop. The utilization of condensate water is applied to AC-split to be tested and investigated whether it can increase the Coefficient of Performance (COP) of the system so that it can lead to saving of power consumption. Power consumption savings of about 3-5% between those using and not using heat exchangers. While at COP there is a percentage increase of 3-6%. Keywords: R410A, water condensation, discharge condenser.

Give Comment ?#(0) | Bookmark

PropertyValue
Publisher IDJBPTPPOLBAN
Organization
Contact NameHelmi Purwanti
AddressJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
CityBandung
RegionJawa Barat
CountryIndonesia
Phone022 201 3789 ext. 168, 169, 239
Fax022 201 3889
Administrator E-mailhelmi.purwanti@polban.ac.id
CKO E-mailhelmi.purwanti@polban.ac.id

Print ...

Contributor...

  • Pembimbing 1: Ir. Sumeru, M.T., Ph.D.

    Pembimbing 2: Triaji Pangripto Pramudantoro, S.T., M.Eng., Editor: Erlin Arvelina

Downnload...