Subjek : Dehumidifier, COP, Efficiency, The volume of water

Sistem refrigerasi dan tata udara kian lama kian berkembang seiring dengan perkembangan zaman, khususnya dalam bidang industri. Dengan kondisi tersebut kebutuhan akan sistem refrigerasi dan tata udara semakin meningkat. Salah satunya adalah pada sistem dehumidifier yang pada dasarnya adalah proses pengkondisi udara yang digunakan untu mengurangi tingkat kelembaban dalam suatu ruangan. Sistem dehumidifier yang digunakan adalah sistem refrigerasi kompresi uap. Sistem ini memproses udara yang dilewatkan pada koil pendingin kemudian molekul udara yang lembab akan terkondensasi menjadi tetesan air. Dalam Tugas Akhir ini dilakukan analisa kinerja sistem dehumidifier yang menggunakan 2 evaporator dengan temperatur yang berbeda untuk dibandingkan. Dari hasil pengujian didapat nilai COP pada evaporator 1 (-10) sebesar 3,63 dan evaporator 2 (10) sebesar 3,86. Efisiensi evaporator 1 sebesar 86 % dan evaporator 2 sebesar 87 %. Kata kunci: Dehumidifier, COP, Efisiensi, Volume air, Evaporator.

Deskripsi Alternatif :

Refrigeration and air conditioning system become expand along with the period's burgeon, especially in industry. With this conditions, the requirement of refrigeration and air conditioning system increase. One of that is dehumidifier system which basically is the process of air conditioning system which used for reduce the moisture level in the room. Dehumidifier system that used is vapor compression refrigeration system. This system is processing the air which is passed in cooling coil and then the moist air molecule will have a condensation become the drift water. Therefore, in this final project is analysis performance by dehumidifier system with 2 evaporators with the different temperature as comparation. From the result of data collection and the calculation, the COP of first evaporator (-10) is 3,63 and the second evaporator (10) is 3,86. The efficiency of first evaporator is 86% and the second evaporator is 87%. Keywords: Dehumidifier, COP, Efficiency, The volume of water.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakHelmi Purwanti
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorhelmi.purwanti@polban.ac.id
E-mail CKOhelmi.purwanti@polban.ac.id

Print ...

Kontributor...

  • Pembimbing 1: Muhammad Nuriyadi, S.T., M.Eng.

    Pembimbing 2: Ir. Sugiyarto, M.T., Editor: Erlin Arvelina

Download...