Analisis Konsumsi Energi Listrik Sistem Heat Pump Pada Saat Pendinginan Dan Pemanasan

Analyze Electrical Power Consumption Of Heat Pump When Cooling And Heating

Skripsi, 014 / 2018 / PTU
Undergraduate Theses from JBPTPPOLBAN / 2019-01-10 11:16:18
By : Firda Dwisophianty - 141624016 (firdadwis.fd@gmail.com)
Created : 2019-01-10, with 4 files

Keyword : Heat pump, pemanasan, pendinginan, konsumsi listrik
Subject : Heat pump, heating, cooling, electricity consumption

Heat pump atau pompa kalor adalah suatu sistem yang memanfaatkan kalor yang dilepaskan di kondensor untuk pemanasan, sehingga tidak dibuang ke lingkungan. Alat ini bisa digunakan untuk proses pendinginan dan pemanasan, dengan mengubah fungsi evaporator menjadi kondensor dengan menggunakan katup. Dalam menjalankan fungsinya, heat pump membutuhkan energi listrik. Listrik ini digunakan untuk menggerakkan motor kompresor. Pada penelitian ini, kajian dilakukan pada heat pump untuk mendinginkan dan memanaskan cokelat yang diletakkan pada kabin berukuran 40x40x40 cm, dengan kapasitas kompresor sebesar 2/5 HP (0,307 kW), menggunakan refrigeran 404A. Temperatur evaporasi -30⁰C sedangkan temperatur kondensasi 40⁰C dan 50⁰C. Hasil penelitian menunjukkan saat proses pemanasan COP mencapai 2,57, EER 1,33 W/W, konsumsi daya listrik 269,8 Watt dan konsumsi energi listrik 0,307 kWh. Sedangkan saat proses pendinginan koefisien performansi (COP) mencapai 1,81, konsumsi daya listrik 233,9 Watt, dan konsumsi energi listrik 0,357 kWh. Kata Kunci: Heat pump, pemanasan, pendinginan, konsumsi listrik.

Description Alternative :

Heat pump is a system that utilizes heat released in the condenser to warm up, so it is not discharged into the environment. This tool can be used for cooling and heating processes, by changing the function of the evaporator into a condenser using a valve. In carrying out its functions, heat pumps require electrical energy. This electricity is used to drive the compressor motor. In this study, a study was carried out on a heat pump to cool and heat chocolate that placed in a 40x40x40 cm cabin, with a compressor capacity of 2/5 HP (0.307 kW), using a R404. Evaporating temperature is -30⁰C while condensing temperature is 40⁰C and 50⁰C. The results of heating process, COP reached 2.57, EER 1.33 W/W, input power 269.8 Watts and electrical energy consumption 0.307 kWh. While the cooling process COP reached 1.81, input power 233.9 Watts, and electrical energy consumption 0.357 kWh. Keywords: Heat pump, heating, cooling, electricity consumption.

Give Comment ?#(0) | Bookmark

PropertyValue
Publisher IDJBPTPPOLBAN
Organization
Contact NameHelmi Purwanti
AddressJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
CityBandung
RegionJawa Barat
CountryIndonesia
Phone022 201 3789 ext. 168, 169, 239
Fax022 201 3889
Administrator E-mailhelmi.purwanti@polban.ac.id
CKO E-mailhelmi.purwanti@polban.ac.id

Print ...

Contributor...

  • Pembimbing 1: Dr. Ir. Andriyanto Setyawan, M.T.

    Pembimbing 2: Tandi Sutandi, S.ST., M.T., Editor: Erlin Arvelina

Downnload...