Rancang Bangun Monitoring Simulasi Temperatur Dan Level Minyak Trafo Daya Menggunakan Sistem Scada Citect

Design And Build Monitoring Simulation Transformer Oil Temperature And Level Controlled By Scada Citect System

Tugas Akhir, 044 / 2018 / TLI
Undergraduate Theses from JBPTPPOLBAN / 2019-05-23 10:35:37
Oleh : Ilham Fikri Heryananda - 151321047 (ilhammahlot@gmail.com)
Dibuat : 2019-05-23, dengan 4 file

Keyword : Minyak trafo, temperatur, level, sensor, scada, citect
Subjek : Oil transformer, temperature, level, sensor, scada, citect

Transformator adalah komponen utama pada Gardu Induk yang gunanya untuk menyalurkan daya listrik dengan mengubah nilai tegangannya. Didalam transformator terdapat minyak yang berguna sebagai isolasi dan juga cooler untuk transformator tersebut. Rancang bangun simulator sistem monitoring temperatur dan level minyak trafo ini digunakan untuk mendeteksi juga sebagai peringatan dini jika terjadi perubahan kondisi dari temperatur dan juga level minyak pada trafo tersebut dengan toleransi error sebesar 10% dan terlebih untuk menambah efisiensi kerja agar operator transformator tersebut dapat memonitoring secara real time tanpa harus melihat langsung transformator tersebut. Temperatur miyak dideteksi oleh sensor RTD PT100 dan sensor level dideteksi oleh sensor level dual balls. Jika nilai dari temperatur melebihi dari set point yang telah ditentukan maka group fan akan menyala dan bahkan buzzer pun akan berbunyi, dan jika level minyak berada pada kondisi low, buzzer pun akan berbunyi. Simulator ini menggunakan aplikasi Citect Scada dan menggunakan komponen jaringan router sehingga simulator ini dapat memonitoring dari jarak jauh dan juga wireless. Kata kunci: Minyak trafo, temperatur, level, sensor, scada, citect.

Deskripsi Alternatif :

The transformer is the main component in the substation which is used to deliver electrical power by changing the voltage value. Inside the transformer there is oil which is useful as insulation and also a cooler for the transformer. The design of the system simulator monitoring the temperature and oil level of this transformer is used to detect and also as an early warning if there is a change in condition of temperature also the level of oil in the transformer with an error tolerance of 10% and especially to increase work efficiency so that the transformer operator can monitor in real time without having to look directly the transformer. The temperature of the oil is detected by the RTD PT100 sensor, and the level sensor is detected by dual balls level sensor. If the value of the temperature exceeds the predetermined set point then the group fan will light up and even the buzzer will sound, and if the oil level is in low condition, the buzzer will sound. This simulator uses the Scada Citect application and uses router network components so that this simulator can monitor remotely and also wireless. Keywords: Oil transformer, temperature, level, sensor, scada, citect.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakHelmi Purwanti
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorhelmi.purwanti@polban.ac.id
E-mail CKOhelmi.purwanti@polban.ac.id

Print ...

Kontributor...

  • Pembimbing 1: Dedi Aming, S.T., M.T.

    Pembimbing 2: Sarjono Wahyu Jadmiko, S.T., M.Eng., Editor: Erlin Arvelina

Download...