Path: Top > Tugas Akhir - D3 > 2017 > Jurusan Teknik Elektro > Program Studi Teknik Listrik > 2017

Audit Energi Listrik Pada Utilitas Di Gedung Polio 2 PT Bio Farma

Electrical Energy Audit On Utility In Polio 2 Building PT Bio Farma

Tugas Akhir, 014 / 2017 / TLI
Undergraduate Theses from JBPTPPOLBAN / 2017-11-13 10:06:42
Oleh : Jehan Nurfauzan - 141321016 (jehan.nurfauzan.tlis14@polban.ac.id)
Dibuat : 2017-11-13, dengan 4 file

Keyword : Potensi Hemat Energi, Audit Energi, Perbaikan Faktor Daya, Intensitas Konsumsi Energi, Harmonisa
Subjek : Power Saving Opportunities, Energy Audit, Energy Consumption Intensity, Power Factor Improvement, Harmonics

Audit energi listrik merupakan suatu cara yang dipakai dalam menghitung kandungan konsumsi energi listrik dalam sistem tertentu, yang bermaksud untuk mendapati potret pemakaian energi listrik dan mengetahui cara yang perlu dilakukan demi meningkatan efisiensi pemanfaatan energi listrik. Tujuan Tugas Akhir ini yaitu untuk mendapati nilai Intensitas Konsumsi Energi listrik, peluang hemat energi, dan mengetahui rekomendasi yang dapat diberikan setelah dilakukannya audit rinci. Metode audit energi rinci yaitu audit energi awal, mengidentifikasi peluang penghematan energi, audit energi rinci, dan memberikan rekomendasi. Pada hasil analisa yang dilakukan, didapatkan harga Intensitas Konsumsi Energi pada PT. Bio Farma sebesar 14.658 kWH/m2/bulan, dengan potensi penghematan energi sebesar Rp. 27.041.540,67,-/bulan. Dilakukan perbaikan faktor daya dengan pemasangan kapasitor bank pada panel Chiller dengan kapasitas 40 kVAR dan 15 kVAR, sedangkan pada panel freezer berkapasitas 4kVAR. Untuk harmonisa arus, terdapat 3 buah panel yang melebihi 8% (standar IEEE 519-1992), yaitu panel DB-2 sebesar 26.56%, panel WTP Polio Sebesar 49.81%, dan panel WTP HIB Pertusis Sebesar 37.65 %, maka harus dipasang filter untuk mereduksi nilai harmonisa arusnya. Harmonisa arus menyebabkan timbulnya panas pada beban dan rugi daya. Dengan dilakukannya pemasangan filter maka terdapat potensi penghematan energi sebesar sebesar 2960.4 kWh/bulan atau Rp. 4.591.994,85,-/bulan untuk panel DB-2, 1491.84 kWh/bulan atau Rp. 2.314.052,69,-/bulan untuk panel WTP Polio, dan 796.8 kWh/bulan atau Rp. 1.235.948,35,-/bulan untuk panel WTP HIB Pertusis. Kata kunci: Potensi Hemat Energi, Audit Energi, Perbaikan Faktor Daya, Intensitas Konsumsi Energi, Harmonisa.

Deskripsi Alternatif :

Electrical energy audit is a method used to calculate the consumption of electrical energy in a particular system, which aims to find a portrait of electrical energy consumption and to know the ways that need to be done in order to increase the efficiency of electrical energy utilization. The purpose of this Final Project is to know the Intensity of Consumption Electrical energy, energy-saving opportunities, and know the recommendations that can be given after a detailed audit. Detailed energy audit methods are initial energy audit, power saving opportunities, detailed energy audit, and provide recommendations. From the results of the analysis conducted the value of Energy Consumption Intensity at PT. Bio Farma 14.658 kWH/m2/month, with the potential energy savings of Rp. 27.041.540,67,-/month. Power factor improvement is done by mounting the capacitor bank on the Chiller panel with capacity of 40kVAR and 15kVAR, while in the freezer panel with a capacity of 4kVAR. For current harmonics, there are 3 panels exceeding 8% (IEEE standard 519-1992), 26.56% on DB-2 panel, 49.81% on WTP Polio panel, and 37.65% on WTP HIB Pertusis panel, the filter must be installed to reduce the current harmonics value. Harmonic current causes heat generation in load and power loss. With the installation of filters there is power saving opportunities about 2960.4 kWh/month or Rp. 4,591,994.85,-/month for panel DB-2, 1491.84 kWh/month or Rp. 2,314,052,69,-/month for Polio WTP panel, and 796.8 kWh/month or Rp. 1.235.948,35,-/month for the panel of WTP HIB Pertussis. Keywords: Power Saving Opportunities, Energy Audit, Energy Consumption Intensity, Power Factor Improvement, Harmonics.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakHelmi Purwanti
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorhelmi.purwanti@polban.ac.id
E-mail CKOhelmi.purwanti@polban.ac.id

Print ...

Kontributor...

  • Pembimbing 1: Ir. Heri Budi Utomo

    Pembimbing 2: Sudrajat, B.Eng., M.Eng.Sc., Editor: Erlin Arvelina