Pengaruh Hambatan Aliran Udara pada Kondensor Terhadap Efisiensi Konsumsi Energi Sistem AC Split
The Influence of Air Flow Resistance On the Condensor to the Efficiency of Energy Consumption of AC Split System
Skripsi, 017 / 2018 / PTUUndergraduate Theses from JBPTPPOLBAN / 2019-01-14 09:34:45
Oleh : Mira Rizki Lestari - 141624019 (mirarizkilestari8496@gmail.com)
Dibuat : 2019-01-14, dengan 4 file
Keyword : Energy Efficiency Ratio (EER), AC Split, kapasitas pendinginan, kenaikan temperatur
Subjek : Energy Efficiency Ratio (EER), AC Split, cooling capacity, temperature raise
Terganggunya aliran udara disekitar kondensor akibat dari adanya penghalang pada sisi masukan dan keluaran udara kondensor dapat menghambat proses pelepasan kalor pada kondensor yang berpengaruh pada performansi sistem, seperti menurunnya kapasitas pendinginan, dan meningkatnya daya input. Penelitian ini bertujuan untuk mengkaji pengaruh dari jarak penghalang pada inlet dan outlet udara kondensor terhadap kapasitas pendinginan, konsumsi daya listrik dan efisiensi konsumsi energi sistem AC Split. Penelitian dilakukan pada AC Split model GWC-09C1/O berkapasitas 1PK atau 8.150 Btu/h yang diletakan pada ruang uji berukuran 1,5 m x 1 m x 2,5 m dengan menggunakan polyurethane sheet di psychrometric chamber Balai Besar Bahan dan Barang Teknik (B4T). Pada penelitian ini diterapkan variasi jarak samping 5 cm, 10 cm, 15 cm dan 20 cm dan jarak belakang 5 cm, 15 cm dan 25 cm. Hasil yang diperoleh dari penelitian ini adalah pengurangan jarak antara outdoor unit dengan dinding penghalang lebih dominan menurunkan kapasitas pendinginan dari pada daya input. terdapat penurunan kapasitas pendinginan sebesar 9% dan kenaikan daya input sebesar 4,78%, yang menyebabkan turunnya Energy Efficiency Ratio (EER) sistem sebesar 12% dari 11,63 Btu/W.h menjadi 10,2 Btu/W.h dari kondisi tanpa penghalang dengan kondisi peletakan jarak belakang 15 cm. Kata kunci: Energy Efficiency Ratio (EER), AC Split, kapasitas pendinginan, kenaikan temperatur.
Deskripsi Alternatif :Air flow disruption around the condenser due to barrier on the air input side and output side condenser can inhibit heat dissipation in the condenser affecting system performance, such as decreased cooling capacity, and increased input power. This study aims to examine the effect of barrier distance on air intake and condenser on cooling capacity, power consumption and efficiency of energy consumption of Split AC system.This study is aimed to examine the effect of barrier distance on air inlet and outlet condenser to cooling capacity, power consumption and efficiency of AC Split energy consumption. This study is conducted on GWC-09C1/O AC Split model with 1 PK capacity or 8.150 BTU/h which placed in test room dimension by 1,5 m x 1 m x 2,5 m using polyurethane sheet in Balai Besar Bahan dan Barang Teknik (B4T) psychrometric chamber. In this study, given variety of side part of condensor distance by 5 cm, 10 cm 15 cm and 20 cm and back part of condenser distance by 5 cm, 15 cm and 25 cm. Result of this study is the reduction of the distance between the outdoor unit and the barrier wall is more dominant decreasing the cooling capacity than the input power. From the condition without a barrier with the condition of 15 cm distance from back, cooling capacity decreased by 9% and input power increased by 4.78%, resulting a 12% drop in the Energy Efficiency Ratio (EER) of the system from 11.63 Btu / W.h to 10.2 Btu / W.h. Keywords: Energy Efficiency Ratio (EER), AC Split, cooling capacity, temperature raise.
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | JBPTPPOLBAN |
Organisasi | |
Nama Kontak | Helmi Purwanti |
Alamat | Jl. Trsn. Gegerkalong Hilir Ds. Ciwaruga |
Kota | Bandung |
Daerah | Jawa Barat |
Negara | Indonesia |
Telepon | 022 201 3789 ext. 168, 169, 239 |
Fax | 022 201 3889 |
E-mail Administrator | helmi.purwanti@polban.ac.id |
E-mail CKO | helmi.purwanti@polban.ac.id |
Print ...
Kontributor...
- Pembimbing 1: Dr. Ir. Andriyanto Setyawan, M.T.
Pembimbing 2: Drs. Faldian, M.Eng.
Pembimbing 3: Hafid Najmudin, S.T., Editor: Erlin Arvelina
Download...
File : KELENGKAPAN SKRIPSI - 141624019.pdf
(946094 bytes)
File : BAB 1 - 141624019.pdf
(235367 bytes)
File : BAB 2 - 141624019.pdf
(426733 bytes)
File : BAB 5 - 141624019.pdf
(270463 bytes)