Path: Top > Tugas Akhir - D3 > 2017 > Jurusan Teknik Elektro > Program Studi Teknik Listrik > 2019
Perancangan Ulang Instalasi Listrik Lantai Dua Gedung Direktorat Politeknik Negeri Bandung
Re-Design of Installation Electric Floor Two Buildings Directorate of State Polytechnic Bandung
Tugas Akhir, 020 / 2019 / TLIUndergraduate Theses from JBPTPPOLBAN / 2020-03-20 10:16:19
Oleh : Muhammad Faris Fazlurahman - 161321021 (feriz.muhammad@gmail.com )
Dibuat : 2020-03-20, dengan 4 file
Keyword : Electrical installation, Design, Lamp Points, Lighting power
Subjek : Instalasi listrik, Perancangan, Titik Lampu, Rating pengamana, Daya pencahayaan
Perancangan Instalasi listrik sangat lah penting adanya pada gedung-gedung atau pun bangunan yang memiliki instalasi listrik didalamnya. Karena dengan adanya perancangan instalasi maka kita akan mengetahui jalur listrik tanpa harus mengecek langsung. Gedung Direktorat Politeknik Negeri Bandung sudah ada sejak tahun 1985, perancangan ini dilakukan pada lantai dua gedung direktorat. Pada lantai dua gedung direktorat ini telah dilakukan pergantian fungsi ruangan dan penambahan beban, namun tidak mengganti peralatan instalasi yang terpasang sejak dulu. Perancangan ini mulai dengan melakukan survei beban maupun jalur instalasi yang terpasang, kemudian menghitung titik lampu. Hasil perhitungan jumlah titik lampu kemudain di bandingkan dengan hasil kalkulasi dengan menggunakan perangkat lunak DiaLux. Kesesuaian tingkat pencahayaan dilakukan dengan cara membandingkan daya pencahayaan maksimum tiap ruang dengan SNI 6197:2011. Rating pengaman MCB hasil perhitungan adalah untuk panel daya 63A dan panel penerangan 16A. Perancangan lantai dua gedung direktorat menghasilkan daya pencahayaan terhitung yang paling besar pada ruangan staff PD 1 sebesar 7,86W/m² dan yang paling kecil pada koridor 3 sebesar 3,20 W/m².
Deskripsi Alternatif :Electrical Installation Design is very important to exist in buildings or buildings that have electrical installations in it. Because with the design of the installation, we will know the electricity line without having to check directly. The Bandung State Polytechnic Directorate Building has existed since 1985, this design was carried out on the second floor of the directorate building. On the second floor of the directorate's building, the room has been replaced and the load added, but has not replaced the installed installation equipment. This design starts by conducting a survey of the load and the installed installation path, then calculates the light point. The results of the calculation of the number of lamp points are then compared with the results of calculations using the DiaLux software. The suitability of the lighting level is done by comparing the maximum lighting power of each room with SNI 6197: 2011. MCB rating from calculated is 63A for power panel and 16A for lighting panel The second floor design of the directorate's building produced the largest calculated lighting power in the PD 1 staff room of 7.86W / m² and the smallest in the corridor 3 of 3.20 W / m².
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | JBPTPPOLBAN |
Organisasi | |
Nama Kontak | Helmi Purwanti |
Alamat | Jl. Trsn. Gegerkalong Hilir Ds. Ciwaruga |
Kota | Bandung |
Daerah | Jawa Barat |
Negara | Indonesia |
Telepon | 022 201 3789 ext. 168, 169, 239 |
Fax | 022 201 3889 |
E-mail Administrator | helmi.purwanti@polban.ac.id |
E-mail CKO | helmi.purwanti@polban.ac.id |
Print ...
Kontributor...
- Pembimbing 1: Yoseph Santosa, S.T., M.Eng.
Pembimbing 2: Trisnawiyana, S.ST., M.Eng.
, Editor: Muhammad Abdillah Islamy, S.Pd
Download...
File : KELENGKAPAN TA - 161321021.pdf
(525402 bytes)
File : BAB 1 - 161321021.pdf
(247923 bytes)
File : BAB 2 - 161321021.pdf
(599891 bytes)
File : BAB 5 - 161321021.pdf
(208434 bytes)