Path: Top > Skripsi - D4 > 2017 > Jurusan Teknik Refrigerasi & Tata Udara > Program Studi Teknik Pendingin & Tata Udara > 2019

Analisis Pengaruh Variasi Kecepatan dan Orientasi Angin pada Kondenser terhadap Kinerja AC Split

Analysis of Speed Variation and Wind Orientation Effect on Condenser for Split AC Performance

Skripsi, 022 / 2019 / PTU
Undergraduate Theses from JBPTPPOLBAN / 2020-06-29 15:34:12
Oleh : Nadya Sefira Salsabilla - 151624023 (nadyasefirasalsabilla@gmail.com)
Dibuat : 2019-12-19, dengan 4 file

Keyword : kondenser, pembuangan panas, kecepatan angin, orientasi angin, kinerja AC Split
Subjek : condenser, heat removal, wind velocity, wind orientation, Split AC performance

Kondenser berfungsi sebagai media pembuangan panas dari refrigeran ke lingkungan sehingga fasa refrigeran uap berubah menjadi cair. Penempatan outdoor unit pada hotel biasanya berada di balkon dan mengakibatkan terhambatnya pembuangan panas oleh kondenser akibat hembusan angin dari lingkungan. Semakin besar tiupan angin, semakin sulit kondenser membuang panas ke lingkungan. Untuk itu dilakukan pengujian dan pengambilan data menggunakan kipas simulator untuk mengetahui pengaruh variasi kecepatan dan orientasi angin terhadap kinerja AC Split. Kipas simulator berperan sebagai angin dan disimpan di depan kondenser dengan variasi kecepatan angin 6,2 m/s dan 8,0 dan variasi orientasi angin 30⁰, 45⁰, 60⁰, dan 90⁰. Hasil pengujian pada AC Split 18.000 Btu/h dengan refrigeran R-410A menunjukkan bahwa kondenser yang diberi semburan angin dengan kecepatan 8,0 m/s dan orientasi angin 90⁰ memberikan pengaruh paling besar terhadap kinerja AC Split. EER turun sebesar 26% dan COPactual turun sebesar 22,8%. Kata kunci: kondenser, pembuangan panas, kecepatan angin, orientasi angin, kinerja AC Split.

Deskripsi Alternatif :

Condenser functions as a heat removal media from refrigerant to the environment so that the refrigerant vapor condenses into liquid. The outdoor unit placement at the hotel is usually on the balcony and thus is affected by the presence of wind from environment. The higher the wind velocity, the more difficult for the condenser to release heat to the surrounding. For this reason, a series of experiment on the effect of wind variation and wind orientation to the performance of an AC system have been carried out. Simulator fan acted as wind and was placed in the front of the condenser with variations in wind speed of 6,2 m/s and 8,0 m/s and variations in wind orientation of 30⁰, 45⁰, 60⁰, and 90⁰. The experiment with 18.000 Btu/h Split AC shows that the wind velocity of 8,0 m/s under 90⁰ orientation gives the most significant effect on the performance of Split AC. The EER and actual COP decreases by 26% and 22.8%, respectively. Keywords: condenser, heat removal, wind velocity, wind orientation, Split AC performance.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakHelmi Purwanti
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorhelmi.purwanti@polban.ac.id
E-mail CKOhelmi.purwanti@polban.ac.id

Print ...

Kontributor...

  • Pembimbing 1: Muhammad Nuriyadi, S.T., M.Eng.



    Pembimbing 2: Dr. Ir. Andriyanto Setyawan, M.T., Editor: Erlin Arvelina

Download...