Path: Top > Skripsi - D4 > Jurusan Teknik Elektro > Prodi Teknik Elektronika > 2014

Electrocradiograph dengan Metode Baseline Correction

Electrocardiograph with Baseline Correction Method

Tugas Akhir, 001 / 2014 / EK
Undergraduate Theses from JBPTPPOLBAN / 2018-09-03 15:06:04
Oleh : Nisa Ikrar Karmila - 101354025 (karmila.nisaikrar@gmail.com)
Dibuat : 2017-07-25, dengan 4 file

Keyword : electrocardiograph, baseline correction, ekstraksi, 3 Lead
Subjek : electrocardiograph, baseline correction, extraction, 3 Lead

Pengukuran sinyal ECG biasanya rentan terhadap noise. Salah satunya adalah baseline wandering yang mengakibatkan pembacaan sinyal menjadi tidak akurat. Oleh karena itu, pada tugas akhir ini dibuat elektrokardiograf 3 lead yang dilengkapi baseline correction untuk menghilangkan baseline wandering noise. Sinyal ECG disadap melalui 4 buah elektroda yang ditempatkan pada kedua tangan dan kaki sesuai konfigurasi Einthoven’s triangle. Sinyal ECG yang terukur selanjutnya diolah secara bertahap. Perbedaan potensial dari tiap lead diukur dan diperkuat sebesar 10 kali menggunakan penguat instrumentasi INA 128. Untuk menghilangkan noise, sinyal ini dilalukan ke high-pass filter aktif (fc = 0,05 Hz) dan diperkuat 11 kali. Kemudian sinyal dilalukan ke low-pass filter (fc 100 Hz) dan diperkuat 11 kali lagi. Level negatif dari sinyal dihilangkan dengan menaikkan komponen DC sebesar 1,2 VDC menggunakan summing amplifier op-amp OP07. Pengolahan sinyal selanjutnya dilakukan oleh mikrokontroler Arduino Uno yang dipilih karena kompatibilitasnya dengan software labVIEW. Dioda ditambahkan sebagai proteksi input mikrokontroler. Sinyal di-sampling menggunakan Analog to Digital Converter (ADC) pada mikrokontroler dengam fs-max 16MHz. Sinyal ditransmisikan ke notebook via Universal Serial Bus (USB) untuk diolah dengan software LabVIEW. Baseline correction dilakukan dengan metoda digital Elliptic high-pass filter orde 2. Wideband noise dibersihkan dengan menggunakan wavelet denoise yaitu Undecimated Wavelet Transform (UWT) 8 level dengan threshold Minimax dan mother wavelet Daubacies 06. Setelah itu, algoritma peak and interval detection serta perhitungan statistik dimanfaatkan untuk ekstraksi sinyal ECG. Terakhir, sinyal ECG ditampilkan dalam bentuk grafik dan hasil ekstraksi dalam bentuk angka. Berdasarkan pengujian dan validasi, alat ini dapat berfungsi dengan baik. Ketiga sinyal ECG yang dari Lead I, II, III ditampilkan secara bersamaan tanpa baseline wandering. Alat ini dapat digunakan untuk memonitor kondisi jantung pasien setiap saat, karena sinyal ECG ditampilkan secara real time dan kontinyu. Kata kunci: electrocardiograph, baseline correction, ekstraksi, 3 Lead.

Deskripsi Alternatif :

Measurement of ECG signal is often contaminated by noise. One type of noise is baseline wandering which make signal readout became inaccurate. Therefore, in this final project has made 3 leads electrocardiograph equipped with baseline correction to eliminate baseline wandering noise. ECG signal tapped trough 4 electrodes which placed in both hands and legs based on Einthoven's triangle configuration. ECG signal which were measured then subsequently processed. Potential difference of each lead is measured and amplified 10 times by instrumentation amplifier INA 128. To eliminate noise, this signal passed through the active high-pass filter (fc = 0,05 Hz) and amplified 11 times. After that, signal is passed through the active low-pass filter (fc 100 Hz) and again amplified 11 times. The negative level of the signal is eliminated by increasing the DC component about 1,2 VDC using summing amplifier op-amp OP07. Signal processing then performed by microcontroller Arduino Uno which chosen because its compatibility with software LabVIEW. Diode is added as input protection of microcontroller. Signal is sampled by analog to digital Converter (ADC in microcontroller with fs-max 16MHz. signal then transmitted to notebook via Universal Serial Bus (USB) to be processed by software LabVIEW. Baseline correction is done by digital Elliptic high-pass filter 2sd order method. Wideband noise is cleaned using wavelet denoise method, that is Undecimated Wavelet Transform (UWT) 8 level with threshold Minimax and mother wavelet Daubacies 06. Afterwards, the algorithm of peak and interval detection plus statistical calculation used for ECG feature extraction signal. Finally, the ECG signal displayed in a graph and the extraction result in numeric Based on test and validation, this device has been able to function properly. The three ECG signal from lead I, II, III can be displayed simultaneously without baseline wandering. This device also can be used to monitor the condition of a patient's heart anytime, because the ECG signal displayed continuously and real time. Keywords: electrocardiograph, baseline correction, extraction, 3 Lead.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakHelmi Purwanti
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorhelmi.purwanti@polban.ac.id
E-mail CKOhelmi.purwanti@polban.ac.id

Print ...

Kontributor...

  • Pembimbing 1: Dr. Ir. Ediana Sutjiredjeki, M.Sc.


    Pembimbing 2: Ervin Masita Dewi, S.T., M.T., Editor: Erlin Arvelina

Download...