Pembuatan Dan Pengujian Air-Conditioner Water Heater Dengan Tipe Direct Heating
Manufacturing and test of Direct Heating Type Air-Conditioning Water Heater
Tugas Akhir, 052 / 2018 / TENUndergraduate Theses from JBPTPPOLBAN / 2019-02-26 09:54:22
Oleh : Novandy Iqbal Fadhillah - 151711052 (nofandyiqbal@gmail.com)
Dibuat : 2019-02-26, dengan 4 file
Keyword : Air-conditioning, kondensor, heat exchanger, pipa tembaga
Subjek : Air-conditioning,condenser, heat exchanger, copper pipe
Manusia selalu senantiasa menginginkan hal baru dengan inovasi maupun dengan teknologi yang sudah dikembangkan saat ini, demi efisiensi maupun kenyaman dalam menjalani kehidupan sehari-hari. Salah satunya adalah dengan menggunakan sistem Air-Conditioning atau AC yang juga biasa disebut pengendali, penyejuk atau pendingin udara. Air-Conditioning ini sudah sangat mudah dijumpai baik di rumah-rumah, mall, industri, hotel dan masih banyak lagi. Selain mempunyai fungsi utama sebagai pendingin ruangan ternyata Air-Conditioning juga menghasilkan efek samping berupa kalor yang sampai saat ini belum dimanfaatkan secara optimal dalam kehidupan sehari-hari. Kalor yang keluar melalui unit condenser pada sistem Air-Conditioning ini sebenarnya masih dapat dimanfaatkan untuk hal lain yang jauh lebih bermanfaat contohnya untuk keperluan mandi, mencuci muka, mencuci pakaian atau keperluan lainnya. Tugas akhir ini membuat water heater yang dicangkokkan dengan sistem Air-Conditioning tipe split yang dibatasi oleh kapasitas pendingin sebesar 12000 Btu/h, pipa tembaga berdiameter 3/8 inch dengan ketebalan 0,70 mm dan menggunakan refrigerant tipe R22. Tipe heat exchanger yang dibuat adalah modifikasi dari heat exchanger tipe double pipe dengan panjang bentang ±6 m dan jumlah lilitan sebanyak 5 lilitan. Kata Kunci: Air-conditioning, kondensor, heat exchanger, pipa tembaga.
Deskripsi Alternatif :Mankind always wants new things with either innovations or technology that has been developed nowadays, for efficiency and comfort in living daily life. One of those is by using Air Conditioning System or AC which can also be called controller, conditioning or air conditioning. Air conditioning can be easily found in houses, malls, industries, hotels, etc. Beside its main function as room air conditioner, Air Conditioning also has resulted a side effect in the form of heat which has not been used optimally until now in daily life. Heat produced out from condenser unit on Air Conditioning system actually still can be used for another purpose which is way more useful, for example is for bathing purpose, washing face, washing clothes or other purposes. In this final project, it has been conducted an examination and construction of water heater that is grafted to Split-type Air Conditioning system which is limited by the cooling capacity of 12000 Btu/h, copper pipe whose diameter is 3/8 inch with thickness of 0,70 mm and using R22 refrigerant. The type of heat exchanger made is modification of double pipe heat exchanger which has span of ±6 m long and 5 windings. Keywords: Air-conditioning,condenser, heat exchanger, copper pipe.
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | JBPTPPOLBAN |
Organisasi | |
Nama Kontak | Helmi Purwanti |
Alamat | Jl. Trsn. Gegerkalong Hilir Ds. Ciwaruga |
Kota | Bandung |
Daerah | Jawa Barat |
Negara | Indonesia |
Telepon | 022 201 3789 ext. 168, 169, 239 |
Fax | 022 201 3889 |
E-mail Administrator | helmi.purwanti@polban.ac.id |
E-mail CKO | helmi.purwanti@polban.ac.id |
Print ...
Kontributor...
- Pembimbing 1: Aceng Daud, S.T., M.Eng.
Pembimbing 2: Ika Yuliyani, S.T., M.T., Editor: Erlin Arvelina
Download...
File : KELENGKAPAN TA - 151711052.pdf
(226313 bytes)
File : BAB 1 - 151711052.pdf
(201489 bytes)
File : BAB 2 - 151711052.pdf
(424959 bytes)
File : BAB 5 - 151711052.pdf
(88340 bytes)