Path: Top > Tugas Akhir - D3 > 2017 > Jurusan Teknik Elektro > Program Studi Teknik Listrik > 2018

Rancang Bangun Simulator Koordinasi Proteksi Pada Jaringan Distribusi Ring Menggunakan Relai Differensial Dan Relai Arus Lebih

Coordination Of Protection Simulator Design On Ring Network Distribution Using Differential Relay And Over Current Relay

Tugas Akhir, 049 / 2018 / TLI
Undergraduate Theses from JBPTPPOLBAN / 2019-05-23 10:51:21
Oleh : Oka Brilian - 151321052 (okabrilian@gmail.com)
Dibuat : 2019-05-23, dengan 4 file

Keyword : Gangguan hubung singkat, Koordinasi relai proteksi, MCGG82, Over Current Relay, Relai differensial
Subjek : Differential relay, MCGG28, Protection relay coordination, Over Current Relay, short circuit interference

Sistem distribusi tenaga listrik umumnya tidak akan luput dari sebuah gangguan. Gangguan yang sering terjadi adalah gangguan hubung singkat yang dapat mengakibatkan kerusakan pada sistem dan komponennya, maka dari itu dibutuhkan suatu proteksi untuk mengisolir gangguan tersebut. Salah satu proteksi yang sering digunakan yaitu Over Current Relay (OCR). OCR disini adalah untuk pembacaan arus gangguan yang terjadi, dan setelah itu OCR akan memerintahkan PMT untuk memutus jaringan yang terdapat gangguan hubung singkat. Untuk mengatasi kegagalan kerja proteksi, maka dibutuhkan proteksi cadangan atau dengan mengkoordinasikan relai proteksi. Relai yang digunakan dalam hal ini adalah relai differensial dan relai Relai Arus Lebih, dimana relai differensial sebagai pengaman utama dan relai Relai Arus Lebih sebagai relai cadangan. Sistem kerja dari relai utama dan cadangan adalah berdasarkan setting waktu, hal tersebut dilakukan untuk mencegah adanya overlap antara proteksi utama dan cadangan. Dalam hal ini waktu pemutusan pengaman utama disetting lebih cepat daripada pengaman cadangan. Kata Kunci: Gangguan hubung singkat, Koordinasi relai proteksi, MCGG82, Over Current Relay, Relai differensial.

Deskripsi Alternatif :

Electrical power distribution systems generally have interruptions. One of the interruptions that usually happens is short circuit interference that may cause damage to its components. Therefore, a protection is needed in order to isolate the interruption. One of the most commonly used protections is Over Current Relay (OCR). OCR is used to detect current noise, and after that, OCR will instruct PMT to disconnect the network that has short circuit interference. To overcome failure protection, a backup protection is needed, or it can be surmounted by coordinating the protection relay. The relay used is a differential relay or MCGG82 relay. The differential relay is used as the main protection while MCGG82 relay is used as the backup protection. The working system of the main and the backup relays is based on the time setting, so the overlap between the main and the backup protections can be prevented. In this case, the main protection time is set sooner than the backup protection. Keywords: Differential relay, MCGG28, Protection relay coordination, Over Current Relay, short circuit interference.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakHelmi Purwanti
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorhelmi.purwanti@polban.ac.id
E-mail CKOhelmi.purwanti@polban.ac.id

Print ...

Kontributor...

  • Pembimbing 1: Supriyanto, S.T., M.T.

    Pembimbing 2: Sunarto, S.T., M.Eng., Editor: Erlin Arvelina