Path: Top > Tugas Akhir - D3 > 2017 > Jurusan Teknik Elektro > Program Studi Teknik Listrik > 2019

Rancang Bangun Penyulut Inverter Satu Fasa untuk Filter Aktif Pereduksi Gangguan Harmonisa

Build and Design Single Phase Inverter Trigger for Active Filter in Reduction Harmonic Disorder

Tugas Akhir, 024 / 2019 / TLI
Undergraduate Theses from JBPTPPOLBAN / 2020-03-23 09:58:34
Oleh : Prayogo Unggul Pangestu - 161321025 (prayogounggul1892@gmail.com )
Dibuat : 2020-03-23, dengan 4 file

Keyword : Harmonic, non-linear load, active filters, inverter trigger
Subjek : Harmonisa, beban non-linear, filter aktif, penyulut inverter

Beban non-linear yang terpasang pada suatu sistem tenaga listrik satu fasa seperti komputer, Air conditioner, TV, pompa air dll dapat menghasilkan distorsi harmonisa arus maupun tegangan. Dengan semakin besarnya kandungan harmonisa pada suatu sistem maka kualitas daya yang dihasilkan pun akan semakin memburuk. Penggunaan filter harmonisa dalam sistem tenaga kelistrikan telah terbukti mampu meredam distorsi harmonisa tegangan maupun arus yang ditimbulkan oleh beban non-linear. Prinsip dasar filter aktif yaitu dengan cara mengambil sumber harmonisa beban untuk dijadikan sinyal referensi kemudian sinyal ini akan masuk ke rangkaian inverter guna diinjeksikan kembali ke sistem. Salah satu bagian penting dalam filter yaitu menghasilkan sinyal penyulut yang sesuai untuk mengontrol inverter. Rancang bangun penyulut filter aktif ini mula-mula disimulasikan terlebih dahulu pada software PSIM/Proteus sebelum dilakukan perancangan alat serta ujicoba. Sebelumnya penulis melakukan pengukuran dengan menggunakan beban induktif-resistif sehingga didapatkan nilai THDI sebesar 24% dan THDV sebesar 3,9%

Deskripsi Alternatif :

Non-linear loads installed on a single-phase electric power system such as computers, air conditioners, TVs, water pumps etc. can produce distortion of current and voltage harmonics. With the greater harmonics in a system, the quality of the power produced will also deteriorate. The use of harmonic filters in the electrical power system has been proven to be able to reduce the harmonic distortion of voltage and current caused by non-linear loads. The basic principle of active filter is by taking a source of load harmonics to be used as a reference signal then this signal will enter the inverter circuit to be injected back into the system. An important part of the filter is to produce an appropriate ignition signal to control the inverter. The design of the active filter igniter is first simulated in the PSIM / Proteus software before designing the device and testing it. Previously the authors made measurements using inductive-resistive loads so that the THDI value of 24% and THDV of 3.9% was obtained.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakHelmi Purwanti
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorhelmi.purwanti@polban.ac.id
E-mail CKOhelmi.purwanti@polban.ac.id

Print ...

Kontributor...

  • Pembimbing 1: Drs. Hasan Surya, S.T., M.T.

    Pembimbing 2: Drs. Kartono Wijayanto., S.T., M.T., Editor: Muhammad Abdillah Islamy, S.Pd

Download...