Perancangan Software Untuk Menghitung Cooling Load, Seleksi Unit, Dan Print Out Data Berbasis Visual Basic
Software Design for Calculating Cooling Load, Unit Selection, and Print Out Data, Based on Visual Basic
Skripsi, 020 / 2018 / PTUUndergraduate Theses from JBPTPPOLBAN / 2019-01-14 10:31:19
Oleh : Rahmadi Aulia Pramudantoro - 141624023 (rahmadi.aulia.tptu414@polban.ac.id)
Dibuat : 2019-01-14, dengan 4 file
Keyword : Visual Basic, perhitungan cooling load, debit diffuser, kebutuhan tata udara gedung, konstruksi gedung
Subjek : Visual Basic, cooling load calculation, debit diffuser, air conditioning need of a building, building construction
Meningkatnya popularitas dari alat pengkondisian udara, yang dapat disesuaikan terhadap iklim yang terjadi. Alat pengkondisi udara dan alat refrigerasi lain telah menjadi kebutuhan dasar dari sebuah industri dan perdagangan, dan masih akan terus meningkat di kemudian hari, setiap gedung - gedung tersebut memiliki jumlah kapasitas pendinginan dan kebutuhan pendinginan yang berbeda dan pastinya penempatan dari ducting-nya pun akan berbeda. Maka dari itu akan dibuat sebuah programhitungan berbasis Visual Basic untuk mempermudah pemilihan kebutuhan tata udara pada suatu bangunan, program ini akan dikhususkan dalam perhitungan dan pemilihan unit AHU sesuai jenis AHU yang cocok untuk sebuah Gedung software ini juga akan mengeluarkan hasil hitungan debit diffuser dan print out data hitungan gedung. Kata Kunci: Visual Basic, perhitungan cooling load, debit diffuser, kebutuhan tata udara gedung, konstruksi gedung.
Deskripsi Alternatif :The increase of popularity of air conditioning unit, that can adjust itself to match the climate. Air conditioning unit and refrigeration unit has been a basic staple among industries and marketing, and it will keep to increase, and every building have different cooling capacity and cooling need thus making the placement of the ducting system may varies. Therefore a calculating programme with visual basic as it base will be created as mean to ease the calculation of air conditioning need for a building, this programme will be specialized to calculate cooling load and diffuser debit according to the building. This programme also will make a print out of building data, Keywords: Visual Basic, cooling load calculation, debit diffuser, air conditioning need of a building, building construction.
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | JBPTPPOLBAN |
Organisasi | |
Nama Kontak | Helmi Purwanti |
Alamat | Jl. Trsn. Gegerkalong Hilir Ds. Ciwaruga |
Kota | Bandung |
Daerah | Jawa Barat |
Negara | Indonesia |
Telepon | 022 201 3789 ext. 168, 169, 239 |
Fax | 022 201 3889 |
E-mail Administrator | helmi.purwanti@polban.ac.id |
E-mail CKO | helmi.purwanti@polban.ac.id |
Print ...
Kontributor...
- Pembimbing 1: Dr. Ir. Andriyanto Setyawan, M.T.
Pembimbing 2: Iwan Chandra, Dipl.Ing., Editor: Erlin Arvelina
Download...
File : KELENGKAPAN SKRIPSI - 141624023.pdf
(821456 bytes)
File : BAB 1 - 141624023.pdf
(147023 bytes)
File : BAB 2 - 141624023.pdf
(279421 bytes)
File : BAB 5 - 141624023.pdf
(259368 bytes)