Merancang dan Menggambar Ulang Instalasi Listrik di Laboratorium Kayu Jurusan Teknik Sipil Politeknik Negeri Bandung

Desaign and Build Medium Voltage Feeder Protection on Substation 70/20 kV

Tugas Akhir, 049 / 2019 / TLI
Undergraduate Theses from JBPTPPOLBAN / 2020-03-26 10:19:47
Oleh : Rahmat Frasetio - 161321052 (rahmat.frasetio@gmail.com )
Dibuat : 2020-03-26, dengan 4 file

Keyword : Medium Voltage Feeders , Short Circuit Interference, Protection Relay
Subjek : Penyulang Tegangan Menengah, Gangguan Hubung Singkat, Relai Pengaman

Penyulang tegangan menengah merupakan salah satu sarana untuk mendistribusikan tenaga listrik dari gardu induk ke konsumen. Tenaga Listrik didistribusikan dengan mengoperasikan peralatan hubung seperti DS, ES, LBS dan CB tentunya. Dalam proses pendistribusian penyulang berjenis SUTM kerap sekali mengalami gangguan dibandingkan penyulang berjenis SKTM. Gangguan yang sering terjadi adalah gangguan akibat hubung singkat. Gangguan Hubung singkat bisa terjadi satu fasa ke tanah, antar fasa dan ketiga fasanya. Ketika terjadi gangguan sistem proteksi yang ada , dalam hal ini adalah relai arus lebih dan relai gangguan tanah harus mampu mengamankan, dan mengisolir daerah tidak terganggu dari adanya gangguan tersebut. Dalam satu buah penyulang biasanya akan diamankan oleh lebih dari relai pengaman, oleh karena itu dalam proses penyetelanya harus diperhitungkan dengan baik agar terciptanya koordinasi antar pengaman yang ada. Pada modul praktikum ini mempunyai dua relai arus lebih bertipe MHREA 200e dan MCGG 82, untuk setting relai dengan karakteristik invers digunakan time – current grading untuk koordinasinya dimana waktu kerja antar pengaman dibedakan dengan selisih waktu 0,4 detik dan untuk besarnya Iset, relai cadangan mempunyai setting arus yang lebih besar dari Iset pengaman utama, untuk relai gangguan tanah besarnya Iset bernilai sama dan setting waktunya dibedakan sebesar 0,4 detik, Kemudian untuk Pemutus Tenaga atau Circuit Breaker disimulasikan menggunakan sebuah kontak dari kontaktor Magnet yang terhubung seri dengan tripping contact pada relai proteksi tersebut. Pada Modul Praktikum ini juga dilengkapi sebuah trafo dengan ratio belitan primer 420V serta ratio belitan sekunder 127 V dengan kapasitas daya 6,6 kVA.

Deskripsi Alternatif :

Medium voltage feeder is one of the means to distribute electricity from substations to consumers. Electricity is distributed by operating connecting equipment such as DS, ES, LBS and CB, of course. In the process of distributing SUTM type feeders, they often experience interference compared to SKTM type feeders. Disorders that often occur are disorders due to short circuit. Interference Short circuit can occur one phase to the ground, between phases and third phase. When there is a disruption of the existing protection system, in this case overcurrent relays and ground fault relays must be able to secure, and isolate the area not disturbed from the existence of the disturbance. In a system of protection, usually one feeder will be secured by more than a safety relay, therefore in the process of setting it must be calculated properly in order to create coordination between safeguards that exist in feeders. In this practicum module, there are two overcurrent relays of type MHREA 200e and MCGG 82, for relay settings with inverse characteristics, time - current grading is used for coordination, where interoperability is distinguished by a difference of 0.4 seconds and for Iset, the backup relay has the current setting is greater than the main safety parameter, for the ground fault relay the size of the Iset is the same and the time setting is distinguished by 0.4 seconds, then for the Breaker or Circuit Breaker itself is simulated using a contactor from the Magnet contactor connected with tripping contact on the overcurrent relay. The Practicum Module also features a transformer with a 420V primary winding ratio and a secondary winding ratio of 127 V with a power capacity of 6.6 kVA.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakHelmi Purwanti
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorhelmi.purwanti@polban.ac.id
E-mail CKOhelmi.purwanti@polban.ac.id

Print ...

Kontributor...

  • Pembimbing 1: Supriyanto, S.T., M.T.


    Pembimbing 2: Sunarto, S.T., M.Eng., Editor: Muhammad Abdillah Islamy, S.Pd

Download...