Path: Top > Skripsi - D4 > 2017 > Jurusan Teknik Refrigerasi & Tata Udara > Program Studi Teknik Pendingin & Tata Udara > 2018

Peningkatan Kinerja Pengkondisi Udara Menggunakan Air Kondensat Sebagai Pendingin Discharge Kompresor Dengan R32 Sebagai Refrigeran

Improvement Of Air Conditioning Performance Using Condensate Water As Discharge Compressor Cooler With R32 As Refrigerant

Skripsi, 021 / 2018 / PTU
Undergraduate Theses from JBPTPPOLBAN / 2019-01-14 10:36:40
Oleh : Rangga Prakhasa - 141624024 (rprakhasa@gmail.com)
Dibuat : 2019-01-14, dengan 4 file

Keyword : Pemanfaatan air kondensat, Konsumsi Energi, Peningkatan performansi, Refrigeran R3
Subjek : Utilizes of condensate water, Energy consumption, Performance improvements, R32 Refrigerant

Oleh karena suhu air kondensat jauh lebih rendah dari suhu discharge kompresor maka ada potensi penggunaan air kondensat sebagai pendingin discharge kompresor. Dengan turunnya suhu discharge kompresor maka ada potensi pengurangan daya input kompresor dan terjadinya subcooling, kedua keuntungan ini akan meningkatkan kinerja sistem pengkondisi udara. Saat ini penggunaan refrigerant R32 sangat dianjurkan sebagai pengganti R22, R410A, R404A dan R407C karena nilai GWP yang rendah yaitu 675. Pada penelitian ini, pengujian dilakukan dengan membandingkan AC Split yang tidak memanfaatkan air kondensat dengan AC Split yang memanfaatkan air kondensat. Penelitian ini dilakukan dengan mengambil data kecepatan udara, suhu udara supply, suhu udara return, suhu discharge, suhu keluar kondenser, tegangan dan arus sistem. Hasil penelitian menunjukan bahwa dengan pemanfaatan air kondensat sebagai pendingin discharge kompresor dapat menurunkan suhu discharge kompresor sebesar 3,646% dan subcooling sebesar 4,908%. Penurunan suhu discharge menyebabkan penurunan daya sebesar 3,429%, penurunan kapasitas kompresor sebesar 3,429%, dan terjadinya subcooling meningkatkan kapasitas pendinginan sebesar 6,683%. Adanya penurunan daya kompresor serta peningkatan kapasitas pendinginan akan menyebabkan peningkatan koefisien performansi sebesar 13,252%. Kata Kunci: Pemanfaatan air kondensat, Konsumsi Energi, Peningkatan performansi, Refrigeran R32.

Deskripsi Alternatif :

Since the condensate water temperature is much lower than the compressor discharge temperature then there come potential for using condensate water as compressor discharge coolant. With the decrease of compressor discharge temperature there come potential reduction of compressor input power and occureance of subcooling, these two advantages will improve the performance of the air conditioning system Currently use of R32 refrigerant is highly recommended as a substitute for R22, R410A, R404A and R407C because of its low GWP value of 675. This research was conducted by comparing the AC Split which does not utilizes condensate water and AC Split which utilizes condensate water. This research was conducted by taking data of air velocity, supply air temperature, return air temperature, compressor discharge temperature, out condenser temperature, voltage and current of system. The results showed that with the use of condensate water as a cooling discharge compressor can reduce the temperature of the compressor discharge by 3,646% and subcooling of 4,908%. The decrease in discharge temperature caused a decrease in power by 3.429%, decreased compressor capacity by 3.429%, and subcooling increased cooling capacity by 6.683%. The decrease of compressor power and increase of cooling capacity will cause the performance coefficient increase of 13.252%. Keywords: Utilizes of condensate water, Energy consumption, Performance improvements, R32 Refrigerant.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakHelmi Purwanti
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorhelmi.purwanti@polban.ac.id
E-mail CKOhelmi.purwanti@polban.ac.id

Print ...

Kontributor...

  • Pembimbing 1: Ir. Sumeru, M.T., Ph.D.

    Pembimbing 2: Tandi Sutandi, S.ST., M.T., Editor: Erlin Arvelina

Download...