Rancang Bangun Heat Pump Menggunakan Sistem Refrigerasi Kompresi Uap Dengan Pengaturan Arah Aliran Oleh Solenoid Valve

Design and Construction of Heat Pump Using Vapour Compression Refrigeration System with Flow Direction Setting by Solenoid Valve

Skripsi, 023 / 2018 / PTU
Undergraduate Theses from JBPTPPOLBAN / 2019-01-14 10:44:31
Oleh : Rhevi Pramana - 141624026 (rhevi.pramana.tptu414@polban.ac.id)
Dibuat : 2019-01-14, dengan 4 file

Keyword : Heat pump, Cokelat, Pemanasan dan Pendinginan
Subjek : Heat pump, Chocolate, Heating and Cooling

Heat pump merupakan alat yang dapat memindahkan kalor dari suatu tempat (sumber) ke tempat lainnya. Perpindahan kalor pada heat pump memiliki 2 (dua) mode yaitu cooling mode dan heating mode. Perubahan mode ini bisa terjadi karena adanya pembalikan arah aliran refrigeran yang dilakukan oleh 4 way reversing valve, untuk meminimalisasi biaya pembuatan dan keperluan percobaan maka komponen tersebut akan diganti dengan 8 buah solenoid valve untuk pengatur arah alirannya. Heat pump biasanya digunakan untuk pengkondisian udara. Pada percobaan ini aplikasi dari heat pump akan digunakan untuk refrigerasi yaitu pelelehan dan pendinginan produk cokelat dengan freezing point ±5 oC serta melting point ±46 oC. Alat yang dirancang berkapasitas 1/7 PK (1300 Btuh) dengan refrigeran R-404a untuk produk cokelat sebanyak 1 kg. Hasil percobaan menunjukkan bahwa sistem dapat mencapai temperatur yang diinginkan selama 40 menit pada proses cooling dan 22 menit pada proses heating. Performansi yang didapat pada masing-masing proses adalah COP 1.92 dengan nilai efisiensi 55,64% untuk proses cooling, sementara untuk proses heating adalah COP 2.63 dan mempunyai nilai efisiensi 65,72%. Biaya operasional mesin yang dikeluarkan per bulan sebesar Rp 169.822,98 Kata Kunci: Heat pump, Cokelat, Pemanasan dan Pendinginan.

Deskripsi Alternatif :

Heat pump is a machine that can transfer the heat from a place to another place. Heat transfer of heat pump has 2 (two) modes, they are cooling mode and heating mode. This changing mode can occur due to the reversal of the direction of the refrigerant flow by four way reversing valve. To minimize the cost of manufacture and the purposes of the experiment then the component will be replaced by 8 pieces of solenoid valve for flow direction regulator. Heat pump is usually used for air conditioning. In this experiment the application of heat pump will be used for refrigerate to melting and solidify the chocolate with freezing point ±5 oC and melting point ±46 oC. The machine is designed with a capacity of 1/7 PK (1300 Btuh) with R-404a refrigerant for 1 kg of chocolate. The experimental results show that the system can reach the desired temperature for 40 minutes in the cooling process and 22 on the heating process. The performance obtained in each process is COP 1.92 with efficiency value of 55,64% for cooling process, while for heating process is COP 2.63 and has efficiency value of 65,72%. The operational cost for one month is IDR 169.822,98 Keywords: Heat pump, Chocolate, Heating and Cooling.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakHelmi Purwanti
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorhelmi.purwanti@polban.ac.id
E-mail CKOhelmi.purwanti@polban.ac.id

Print ...

Kontributor...

  • Pembimbing 1: A. P. Edi Sukamto, S.T., M.T.

    Pembimbing 2: Ir. Arda Rahardja Lukitobudi, M.Eng., Editor: Erlin Arvelina

Download...