Path: Top > Skripsi - D4 > 2017 > Jurusan Teknik Sipil > Program Studi Teknik Perawatan & Perbaikan Gedung > 2017

Evaluasi Dan Perancangan System Proteksi Kebakaran Pasif Pada North Tower Hotel Grand Tjokro Bandung

Fire Safety Protection System Evaluation and Planning at North Tower Hotel Grand Tjokro Bandung

Tugas Akhir, 025 / 2017 / TPPG
Undergraduate Theses from JBPTPPOLBAN / 2018-09-03 15:05:26
Oleh : Rina Riani - 121144029 (rrianirina@gmail.com)
Dibuat : 2018-02-19, dengan 4 file

Keyword : keandalan bangunan, tangga darurat, proteksi pasif, kebakaran, Grand Tjokro Bandung
Subjek : structure resiliency, emergency stairs, passive protection, fire, Grand Tjokro Bandung

North Tower Hotel Grand Tjokro Bandung berfungsi sebagai perhotelan dengan luas total bangunan 28.300 m² yang dibagi menjadi dua tower yaitu Main Tower dan North Tower. Merujuk pada Studi Kasus terdahulu Rina Riani mengenai "Identifikasi Sistem Pencegahan Bahaya Kebakaran pada North Tower Hotel Grand Tjokro Bandung", menunjukan bahwa hotel tersebut tidak memiliki jalur evakuasi (pintu darurat, tangga darurat dan marka evakuasi), jalur pemadam kebakaran, serta arah evakuasi yang memenuhi persyaratan. Sehingga pada penelitian ini akan dilakukan evaluasi mengenai keandalan bangunan terhadp komponen struktur dan non struktur serta perancangan sistem proteksi kebakaran pasif pada North Tower Hotel Grand Tjokro Bandung Pada penelitian ini, evaluasi yang dilakukan terhadap komponen struktur menggunakan Hammer Test dan untuk komponen non struktur dilakukan dengan cara inspeksi visual dibandingkan dengan standar yang berlaku. Setelah dievaluasi, dilakukan perancangan ulang terhadap sistem proteksi kebakaran pasif yang belum sesuai. Setelah itu, dilakukan perhitungan Rencana Anggaran Biaya (RAB) terhadap perancangan yang telah dibuat. Hasil Evaluasi terhadap keandalan bangunan yang didapat dari pengujian Hammer test dan inspeksi visual maka bangunan ini perlu dilakukan rekomendasi perbaikan komponen bangunan. Untuk sistem proteksi kebakaran pasif meliputi jalur evakuasi, sistem kompartemenisasi, jarak antar bangunan serta jalan lingkungan berdasarkan perbandingan yang mengacu pada peraturan yang berlaku, maka perlu dilakukan perencanaan ulang pada sebagian sistem diantaranya jalur evakuasi (pintu darurat, tangga darurat, marka evakuasi0 dan Jalan Lingkungan. Kata Kunci: keandalan bangunan, tangga darurat, proteksi pasif, kebakaran, Grand Tjokro Bandung.

Deskripsi Alternatif :

North Tower Hotel Grand Tjokro Bandung serves as a hotel area which covers 28.300m2 of land. This structure is divided into two parts: Main Tower and North Tower. Referring to the previous case study of Rina Riani about "Fire Safety Identification System at North Tower Hotel Grand Tjokro Bandung", it gives us information that the hotel does not provide sufficient safety measures, such as evacuation path (emergency door, emergency stairs, and evacuation sign), firefighter path, and proper evacuation direction. Hence, in this research, the researcher considers to evaluate the structure resiliency and passive fire protection system at North Tower Hotel Grand Tjokro Bandung. Furthermore, the evaluation conducted to the structure component will use Hammer Test, and the evaluation conducted to the non-structural component will use visual inspection with a comparation to the applied standard regulation. After doing the evaluation, the researcher will conduct a re-planning program towards the fire safety system in the hotel which is not based on the applied standard regulation. The calculation of the financial estimation then will be calculated on a budget plan or Rencana Anggaran Biaya (RAB). According to the findings of structure resiliency through component evaluation using Hammer test and visual inspection, this building needs to improve several recommendations about the structure component aspect. In term of passive fire protection system, the recommendations are evacuation path, compartmentalization system, the distance between each building, and the environmental road based on the applied standard comparation. The re-planning system is important especially in evacuation path (emergency doors, emergency stairs and evacuation sign) and Environmental Road. Keywords: structure resiliency, emergency stairs, passive protection, fire, Grand Tjokro Bandung.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakHelmi Purwanti
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorhelmi.purwanti@polban.ac.id
E-mail CKOhelmi.purwanti@polban.ac.id

Print ...

Kontributor...

  • Pembimbing 1: Ahmad Sofyan, S.ST., M.Eng.


    Pembimbing 2: Ir. RR. Elisabeth Marlailana, M.T., Editor: Erlin Arvelina

Download...