Keyword : Refrigerator, pipa kapiler, kinerja sistem, bayam
Subjek : Refrigerator, capillary tube, system performance, Spinach

Refrigerator merupakan salah satu mesin pendingin yang banyak digunakan untuk penyimpanan produk buah-buahan, sayuran, minuman, dan makanan yang dijaga temperaturnya diatas 0⁰C. Produk yang digunakan dalam tugas akhir ini yaitu bayam dengan temperatur penyimpanan yang direkomendasikan sebesar 5⁰C. Sistem yang digunakan pada refrigerator ini adalah sistem refrigerasi kompresi uap dengan menggunakan kompresor hermetik, jenis refrigeran yang digunakan yaitu R134a, dan pipa kapiler sebagai alat ekspansinya. Pipa kapiler dengan ukuran panjang yang berbeda digunakan pada sistem refrigerator penyimpanan bayam ini. Pengujian yang dilakukan adalah untuk mengetahui kinerja sistem dengan membandingkan variasi panjang pipa kapiler dengan menggunakan metode pengambilan dan pengolahan data untuk mengetahui panjang pipa kapiler paling baik yang digunakan pada refrigerator. Hasil yang diperoleh setelah melakukan pengujian data terhadap tiga variasi panjang pipa kapiler, panjang pipa kapiler 1,04m menghasilkan nilai COPaktual rata-rata sebesar 3,87, efisiensi sebesar 67,87%, konsumsi energi listrik sebesar 0,546 kWh. Pada panjang pipa kapiler 1,14m menghasilkan nilai COPaktual rata-rata sebesar 3,72, efisiensi sebesar 65,91%, konsumsi energi listrik sebesar 0,474 kWh. Pada panjang pipa kapiler 1,25m menghasilkan nilai COPaktual rata-rata sebesar 3,85, efisiensi sebesar 67,64%, konsumsi energi listrik sebesar 0,343 kWh. Berdasarkan hasil pengujian, panjang pipa kapiler 1,25m menghasilkan kinerja sistem yang lebih baik. Kata kunci: Refrigerator, pipa kapiler, kinerja sistem, bayam.

Deskripsi Alternatif :

Refrigerator is one of the major cooling machine that widely used to storage fruits, vegetables, kind of drinks, foods with the temperature maintain at 0⁰C. The products that used for this Thesis is Spinach with the temperature 5⁰C for storage. This refrigerator use a vapor compression with a R134a hermetic compressor and capillary tube as expansion valve. The refrigerator use a different lenght for capillary tube. The purpose of this Thesis is to find out the performance by comparing the capillary tube which one is the best for the refrigerator. The result after done the testing are : for the capillary tube with the lenght of 1,04m the average COP is 3,87 with the efficiency 67,87%, and the energy consumption is 0,546 kWh. For the capillary tube with the lenght of 1,14m the average COP is 3,72 with the efficiency 65,91%, and the energy consumption 0,474 kWh. For the capillary tube with the lenght of 1,25m the average COP is 3,85 with the efficiency is 67,64%, and the energy consumption is 0,343 kWh. Based on the result of the test the capillary tube with the lenght of 1.25m have a better performance. Keywords: Refrigerator, capillary tube, system performance, Spinach.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakHelmi Purwanti
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorhelmi.purwanti@polban.ac.id
E-mail CKOhelmi.purwanti@polban.ac.id