Analisis Perbandingan Kinerja Pengondisi Udara Menggunakan Pipa Kapiler Dan Ejektor Sebagai Alat Ekpansi Dengan Variasi Temperatur

Comparative Performance Analysis Of Air Conditioner Using Capillary Tube And Ejector As Expansion Device With Variation Temperature

Tugas Akhir, 054 / 2014 / RTU
Undergraduate Theses from JBPTPPOLBAN / 2018-04-19 11:37:14
By : Viktorius Iwan - 111611063 (iwan_ordos@rocketmail.com)
Created : 2018-04-19, with 4 files

Keyword : Chilled Beam, Performansi water chiller, Kapasitas pendinginan
Subject : Chilled Beam, Performance of water chiller, Cooling Capacity

AC split merupakan sistem tata udara yang paling umum digunakan pada hunian, perkantoran dan juga perhotelan. Banyaknya penggunaan AC Split mengakibatkan konsumsi energi yang dibutuhkan menjadi lebih banyak, sehingga dibutuhkan metode untuk meningkatkan kinerja AC Split yang sangat diperlukan agar konsumsi energi listrik dapat dikurangi. Salah satu metode yaitu dengan menggunakan ejektor sebagai alat ekspansi. Dalam tugas akhir ini telah dilakukan penelitian terhadap perbandingan antara kinerja AC Split yang menggunakan ejektor sebagai alat ekspansi dengan AC Split yang menggunakan pipa kapiler sebagai alat ekspansi pada temperatur lingkungan 30oC, 35oC, dan 40oC. Ejektor digunakan untuk membandingkan COP dan besarnya daya listrik yang diperlukan dengan pipa kapiler. Dari data yang telah dihasilkan ada peningkatan COP aktual dan penurunan konsumsi daya listrik setelah menggunakan ejektor sebagai alat ekspansi degan variasi temperatur. Kata kunci: Chilled Beam, Performansi water chiller, Kapasitas pendinginan.

Description Alternative :

AC split is an air conditioning system which is most commonly used in residential, office and hotel. So many AC split utilizing causes more energy consumes, so a methode for increasing the AC split performance is needed which is very important for reduce electricity consumption. On of the methodes is using ejector as expansion device. In this final project has been done a research about comparison between AC split performance which is using ejector and capillary tube as expansion device in 30oC, 35oC, and 40oC ambient temperature. Ejector is used to compare the COP and the magnitude of electrical power required by capillary tube. From the data that has been produced is the actual COP improvement and reduction of electric power consumption when using the ejector as an expansion device with variation temperature. Keywords: Chilled Beam, Performance of water chiller, Cooling Capacity.

Give Comment ?#(0) | Bookmark

PropertyValue
Publisher IDJBPTPPOLBAN
Organization
Contact NameHelmi Purwanti
AddressJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
CityBandung
RegionJawa Barat
CountryIndonesia
Phone022 201 3789 ext. 168, 169, 239
Fax022 201 3889
Administrator E-mailhelmi.purwanti@polban.ac.id
CKO E-mailhelmi.purwanti@polban.ac.id

Print ...

Contributor...

  • Pembimbing 1: Ade Suryatman Margana, S.T., M.Eng.

    Pembimbing 2: Luga Martin Simbolon, S.T., M.Sc., Editor: Erlin Arvelina

Downnload...