Path: Top > Skripsi - D4 > 2017 > Jurusan Teknik Refrigerasi & Tata Udara > Program Studi Teknik Pendingin & Tata Udara > 2019

Kaji Eksperimental Pemanfaatan Kondensat Untuk Mendinginkan Liquid Line Pada Chest Cooler Yang Menggunakan Pendinginan Radian

The Experimental Study of the Effect of Condensate for Cooling Liquid Line on Chest cooler That Used Radiant Cooling

Skripsi, 030 / 2019 / PTU
Undergraduate Theses from JBPTPPOLBAN / 2020-06-29 15:33:34
Oleh : Wendra Luthfi Abdul Latief - 151624031 (wendra.luthfi.tptu415@polban.ac.id)
Dibuat : 2019-12-19, dengan 4 file

Keyword : pendinginan radian, HX (heat exchanger), kondensat, chilling time, konsumsi daya, efisiensi
Subjek : radiant cooling, HX (heat exchanger), condensate, chilling time, power consumption, eficiency

Pendinginan radian (radiant cooling) adalah metode pendinginan dengan menggunakan permukaan kabin yang didinginkan untuk menyerap panas dari produk dengan proses radiasi dan konveksi. Berbeda dengan metode pendingin "all-air" yang hanya mensirkulasikan udara yang telah didinginkan, metode pendinginan radian mensirkulasikan refrigeran dingin ke dalam pipa melalui saluran pemipaan yang dipasang secara khusus ditanam pada dinding semen kabin berukuran 0,5x0,5x0,5 meter (m), kabin tersebut digunakan untuk menyimpan tomat dengan massa 1kg (kilogram) dan temperatur di dalam kabin dijaga 5o.C. Pada seluruh permukaan dinding yang didinginkan akan terbentuk kondensat secara alami. Tujuan dalam penelitian ini adalah memanfaatkan kondensat tersebut untuk mendinginkan pipa liquid line kemudian membandingkan kinerja sistem, chilling time dan konsumsi energi listrik antara sistem yang menggunakan HX kondensat dan sistem yang tidak menggunakan HX kondensat. Mesin yang digunakan pada penelitian ini adalah mesin pendingin chest type berkapsitas pendinginan 2930,7 watt dengan metode pendinginan radian. Hasil penelitian ini menunjukkan bahwa efisiensi terbesar diperoleh sistem yang menggunakan HX kondensat dengan nilai rata-rata 82,58%, sedangkan efisiensi rata rata sistem yang tidak menggunakan HX kondensat sebesar 80,66%. Sistem yang menggunakan HX kondensat memperoleh chilling time tercepat yaitu 35 menit, sedangkan chilling time pada sistem yang tidak menggunakan HX kondensat adalah 38 menit. Perolehan konsumsi daya terhemat diperoleh sistem yang menggunakan HX kondensat dengan konsumsi daya sebesar 0,635 kWh (kilowatt hour), sedangkan konsumsi daya pada sistem yang tidak menggunakan HX kondensat sebesar 0,701 kWh. Kata Kunci: pendinginan radian, HX (heat exchanger), kondensat, chilling time, konsumsi daya, efisiensi.

Deskripsi Alternatif :

Radiant cooling is cooling method by using conditioned cabin surfaces to absorb heat from the product by radiation and convection. Radiant cooling is different from all-air method which only circulates air that has been cooled, radian cooling method circulates refrigerant into pipes that planted on the wall of cabin, cabin’s dimension is 0,5x0,5x0,5 m (meter), The cabin is using for store tomatoes wit a mass of 1kg (kilogram) and setting themperatur of cabin is 5o.C. On all cooled wall surfaces, condensate will form naturally. The purpose of this study is to use that condensate for cooling liquid line pipe and compare performance of system, chilling time, and power consumption of the system between system that using HX HX condensate and system that does not use HX condensate. Machine used in this study is chest cooler with cooling capacity 2930,7 watt using radiant cooling method. The result of this study indicate that the greatest eficiency value is obtained in the system with HX condensate, the average value is 82,58%, while the efficienc of the system without HX condensate is 80,66%. System with HX condensate obtain fastest chilling time, it is 35 minutes, while chilling timr of system without HX condensate is 38 minutes. The most economical power consumption is obtained by system with HX condensate which consumes 0,635 kWh (kiloWatt Hour), while the system without HX condensate consumes 0,701 kWh. Keywords: radiant cooling, HX (heat exchanger), condensate, chilling time, power consumption, eficiency.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakHelmi Purwanti
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorhelmi.purwanti@polban.ac.id
E-mail CKOhelmi.purwanti@polban.ac.id

Print ...

Kontributor...

  • Pembimbing 1: Ir. Arda Rahardja Lukitobudi, M.Eng.



    Pembimbing 2: Tandi Sutandi, S.ST., M.T., Editor: Erlin Arvelina

Download...