Path: Top > Tugas Akhir - D3 > 2017 > Jurusan Teknik Elektro > Program Studi Teknik Elektronika > 2020
Alat Pendeteksi Peripheral Arterial Disease menggunakan Metode Ankle Brachial Index
Peripheral Arterial Disease Detector using Ankle Brachial Index Method
Tugas Akhir, 041 / 2020 / TELUndergraduate Theses from JBPTPPOLBAN / 2021-05-17 15:31:18
Oleh : 171311048 - Gema Ramadhan (gemaramadhan20@gmail.com)
Dibuat : 2021-04-29, dengan 4 file
Keyword : Pheripheral Arterial Disease, Ankle Brachial Index, Oscillometry, Blood Pressure
Subjek : Pheripheral Arterial Disease, Ankle Brachial Index, Osilometri, Tekanan darah
Pheripheral Arterial Disease (PAD) merupakan penyakit yang menggambarkan keadaan pembuluh darah arteri seseorang. PAD merepresentasikan pembuluh darah yang mengalami penyumbatan oleh plak yang menumpuk di sekitar dinding arteri. PAD termasuk kedalam kategori penyakit yang seringkali terlambat untuk diketahui dan berimbas pada kasus yang lebih parah, seperti matinya jaringan atau bagian tubuh tertentu. Ankle Brachial Index (ABI) merupakan metode non-invasife yang akurat untuk mendiagnosa PAD, dalam praktiknya ABI biasa dilakukan di rumah sakit tertentu dan masih sulit ditemui karena keterbatasan alat. Berdasarkan kondisi tersebut maka dibuatlah alat yang dapat mendeteksi kondisi PAD seseorang berdasarkan nilai ABI. Sistem dilengkapi dengan dua buah sensor MPX5050GP untuk mendeteksi pulsa pulsa osilometri. Sistem menggunakan pompa DC dan solenoid valve sebagai aktuator untuk memompa dan mengempiskan manset. ADS1115 digunakan dalam sistem sebagai ADC eksternal untuk meningkatkan ketelitian pembacaan sensor. Output dari sistem ditampilkan dalam bentuk print out oleh thermal printer. Sistem memiliki LCD dan buzzer sebagai indikator bagi kondisi sistem. Alat ini memiliki sistem keamanan tatkala terjadi kegagalan dalam proses pengukuran, yaitu emergency stop yang berfungsi memutus supply pada aktuator. Metode yang digunakan untuk mendeteksi tekanan sistole dan diastole ialah metode osilometri. Pengujian sistem dilakukan dengan melakukan pengujian pada tiap bagian lalu dilakukan pengujian pembacaan nilai sistole dan diastole pada tangan dan kaki dan dibandingkan dengan tensimeter Aneroid, pengujian validitas alat dilakukan dengan menguji sistole dan diastole pada tangan dan kaki dan didapat error rata â rata untuk sistole tangan adalah 3,41%, untuk diastole tangan 4,20%, untuk sistole kaki 5,33% dan untuk diastole kaki 5,36%.
Deskripsi Alternatif :Pheripheral Arterial Disease (PAD) is a disease that describes the condition of a person's blood vessels. PAD represents a blood vessel that is blocked by plaque that has accumulated around the artery wall. PAD is type of underrated disease and have an impact on more cases, such as the death of certain tissues or body parts. Ankle Brachial Index (ABI) is an accurate, non-invasive method for diagnosing PAD, in practice ABI is usually done in certain hospitals and is still difficult to find due to limited tools. Based on these conditions, a tool is made that can serve a person's PAD condition based on the ABI value. The system is equipped with two MPX5050GP sensors for checking oscillometric pulses. The system uses a DC pump and a solenoid valve as aktuators for pumping and deflating the cuff. ADS1115 is used in the system as an external ADC to increase the accuracy of sensor readings. The output of the system is printed by a thermal printer. The system has an LCD and a buzzer as an indikator for system conditions. This tool has a safety system when a failure occurs in the measurement process, it is an emergency stop which functions to cut off the supply to the aktuator. The method used to overcome systolic and diastolic pressures is the oscillometric method. System testing is carried out by testing each section then testing the reading of systole and diastole values on the hands and feet and compared with Aneroid tensimeter, the validation of system is done by measuring systole and diastole from hand and foot, the average error for hand systole is 3.41%, for hand diastole 4.20 %, for foot systole 5.33% and for diastole feet 5.36%.
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | JBPTPPOLBAN |
Organisasi | |
Nama Kontak | Erlin Arvelina |
Alamat | Jl. Trsn. Gegerkalong Hilir Ds. Ciwaruga |
Kota | Bandung |
Daerah | Jawa Barat |
Negara | Indonesia |
Telepon | 022 201 3789 ext. 168, 169, 239 |
Fax | 022 201 3889 |
E-mail Administrator | erlin.arvelina@polban.ac.id |
E-mail CKO | erlin.arvelina@polban.ac.id |
Print ...
Kontributor...
- Pembimbing 1: Ervin Masita Dewi, S.T., M.T.
Pembimbing 2: Dadan Nurdin Bagenda, S.T., M.T., Editor: Muhammad Abdillah Islamy, S.Pd
Download...
File : KELENGKAPAN TA - 171311048.pdf
(1091532 bytes)
File : BAB 1 - 171311048.pdf
(310222 bytes)
File : BAB 2 - 171311048.pdf
(548697 bytes)
File : BAB 5 - 171311048.pdf
(298923 bytes)