Path: Top > Skripsi - D4 > 2017 > Jurusan Teknik Konversi Energi > Program Studi Teknologi Pembangkit Tenaga Listrik > 2023
Rancangan Tap-Changer Elektronik pada Transformator Generator Kapasitas 66mva, 13,8kv/150kv
Design Of Electronic Tap-Changer for A 66mva, 13,8kv/150kv Generator Transformer
Skripsi, 016 / 2023 / TPTLUndergraduate Theses from JBPTPPOLBAN / 2024-03-20 11:23:54
Oleh : 191724014 - Jihan Kanitha (Jihan.kanitha.tptl19@polban.ac.id)
Dibuat : 2024-03-20, dengan 4 file
Keyword : Electronic Tap-Changer, Transformator, PLTP
Subjek : Electronic Tap-Changer, Transformator, PLTP
Tap-Changer adalah komponen yang digunakan dalam sistem distribusi dan transmisi untuk mengontrol level tegangan. Ada tiga jenis Tap-Changer yang umum digunakan, yaitu off-circuit Tap-Changer, no-load Tap-Changer, dan under-load Tap-Changer. Tap-Changer berfungsi untuk mengubah perbandingan transformasi dan mendapatkan tegangan operasi sekunder yang diinginkan agar sesuai dengan tegangan pelayanan. Perkembangan terbaru dalam teknologi smart device telah mengarah pada perkembangan smart transformer, yang memiliki fungsi tambahan untuk mengontrol pengiriman daya, memantau perilaku beban konsumen, dan lain-lain. Komponen kunci dari smart transformer adalah under-load Tap-Changer (OLTC), yang memungkinkan perubahan level tegangan dan aliran daya. OLTC elektronik sepenuhnya tidak menggunakan komponen yang bergerak seperti pada Tap-Changer mekanikal, sehingga menghindari masalah arc yang berlebihan pada kontak diverter saat proses perubahan tap. Kelebihan OLTC elektronik antara lain biaya maintenance yang rendah, kecepatan tinggi dalam proses perubahan tap, dapat melakukan tap jumping, dan tidak ada batasan dalam mengganti tap. Metode yang digunakan dimulai dari mencari studi literatur, menghitung thyristor yang cocok digunakan pada komponen elektronik, menentukan hyristor yang cocok untuk simulasi, lalu mensimulasikannya pada software, terakhir dilakukan analisis terhadap rancangan electronic Tap-Changer untuk PLTP Darajat pada tegangan, arus, daya serya kecepatan tap-changer tersebut. Dalam analisis tersebut, ditemukan bahwa perbedaan level tegangan telah sesuai dengan manualbook transformator yang digunakan di PLTP Darajat yaitu antara 1,22%-2,26% dibandingkan dengan manualbook sebesar 1,25%. Hasil arus dan tegangan juga sesuai dengan keluaran daya yang dihasilkan oleh PLTP Darajat. Rancangan electronic Tap-Changer juga mampu melakukan tap-jumping dan memiliki waktu perubahan tap yang cepat dengan rata-rata 1,108s untuk kenaikan tap yang mengurut, 0,974s untuk tap-jumping.
Deskripsi Alternatif :Tap-Changer is a component used in distribution and transmission systems to control voltage levels. There are three commonly used types of Tap-Changers: off-circuit Tap-Changer, no-load Tap-Changer, and under-load Tap-Changer. The Tap-Changer functions to alter the transformation ratio and achieve the desired secondary operating voltage to match the service voltage. Recent advancements in smart device technology have led to the development of smart transformers, which have additional functionalities such as power delivery control, monitoring of consumer load behavior, and more. The key component of a smart transformer is the under-load Tap-Changer (OLTC), which enables voltage level and power flow changes. Electronic OLTC completely eliminates moving parts found in mechanical Tap-Changers, thereby avoiding excessive arc issues on the diverter contacts during the tap-changing process. The advantages of electronic OLTC include low maintenance costs, high speed in tap-changing processes, tap jumping capability, and no limitations in tap replacement. The methodology employed begins with literature review, calculation of suitable thyristors for electronic components, selection of appropriate thyristors for simulation, followed by software-based simulations, and finally, an analysis of the electronic Tap-Changer design for the Darajat Geothermal Power Plant (PLTP) in terms of voltage, current, power, and tap-changing speed. In this analysis, it was found that the voltage level differences were in accordance with the transformer manualbook used in the Darajat Geothermal Power Plant, ranging from 1.22% to 2.26%, compared to the manualbook value of 1.25%. The current and voltage results also matched the power output generated by the Darajat Geothermal Power Plant. The electronic Tap-Changer design was also capable of tap-jumping and exhibited fast tap-changing times, with an average of 1.108 seconds for sequential tap increases and 0.974 seconds for tap-jumping.
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | JBPTPPOLBAN |
Organisasi | |
Nama Kontak | Erlin Arvelina |
Alamat | Jl. Trsn. Gegerkalong Hilir Ds. Ciwaruga |
Kota | Bandung |
Daerah | Jawa Barat |
Negara | Indonesia |
Telepon | 022 201 3789 ext. 168, 169, 239 |
Fax | 022 201 3889 |
E-mail Administrator | erlin.arvelina@polban.ac.id |
E-mail CKO | erlin.arvelina@polban.ac.id |
Print ...
Kontributor...
- Pembimbing 1: Ali Mashar, M.Eng.Sc.
Pembimbing 2: Dr. I Made Wiwit Kastawan, M.T., Editor: Erlin Arvelina
Download...
File : KELENGKAPAN SKRIPSI - 191724014.pdf
(1725997 bytes)
File : BAB 1 - 191724014.pdf
(442482 bytes)
File : BAB 2 - 191724014.pdf
(935984 bytes)
File : BAB 5 - 191724014.pdf
(404932 bytes)