Path: Top > Skripsi - D4 > 2017 > Jurusan Teknik Konversi Energi > Program Studi Teknologi Pembangkit Tenaga Listrik > 2023
Rancangan Modifikasi Turbine Washing Line di PLTP Darajat Kamojang POMU
Modification Design of Turbine Washing Line at Darajat Geothermal Power Plant Kamojang POMU
Skripsi, 023 / 2023 / TPTLUndergraduate Theses from JBPTPPOLBAN / 2024-03-20 12:04:26
Oleh : 191724024 - Muhammad Naufal Daffa (muhammad.naufal.tptl19@polban.ac.id)
Dibuat : 2024-03-20, dengan 4 file
Keyword : pipa, turbine washing, valve, fitting, tegangan
Subjek : pipe, turbine washing, valve, fitting, stress
Sistem turbine washing eksisting di PLTP Darajat Kamojang POMU memiliki beberapa kelemahan yang dapat mengganggu keandalan unit PLTP. Beberapa kelemahan tersebut diantaranya adalah kebutuhan suplai uap tambahan selama kegiatan turbine washing, kesulitan proses kondensasi uap menjadi air untuk kebutuhan turbine washing, dan pembuangan air pendingin pada HE di sistem turbin washing langsung menuju cold basin cooling tower tanpa dilakukan pendinginan. Beberapa kelemahan tersebut mengakibatkan performa unit terganggu selama kegiatan turbine washing, karena turbine washing dilakukan ketika unit beroperasi. Berdasarkan latar belakang tersebut penulis akan merancang jalur modifikasi untuk alternatif sumber air panas yang dibutuhkan untuk kegiatan turbine washing yang sebelumnya menggunakan hasil kondensasi uap menjadi memakai air panas yang dipakai untuk mengkondensasikan uap di heat exchanger. Hasil rancangan ini mempertimbangkan sistem eksisting dengan minimal parameter yang dibutuhkan. Ukuran pipa yang digunakan adalah DN 50 mm dengan material ASTM 312 Gr. TP316L. Panjang total jalur rancangan adalah 2,8 m yang terdiri dari satu buah reducer ukuran 250 x 50 mm, tiga buah elbow 90 derajat, dan satu buah gate valve yang digunakan untuk menghitung head losses minor. Perhitungan tegangan dilakukan dengan mengacu pada standar ASME B31.3 untuk batas tegangan yang diizinkan. Hasil rancangan jalur pipa kemudian dimodelkan pada software CAESAR 2019 untuk dilakukan verifikasi perhitungan tegangan. Perhitungan tegangan antara manual dengan hasil simulasi menunjukkan persentase di bawah standar ASME B31.3, yaitu 4,3% untuk sustained load (beban akibat berat pipa) dan 3,6% untuk expansion load (beban ekspansi). Kata kunci: pipa, turbine washing, valve, fitting, tegangan.
Deskripsi Alternatif :The existing turbine washing system at Darajat Geothermal Power Plant (PLTP) Kamojang POMU has several weaknesses that can affect the reliability of the PLTP unit. Some of these weaknesses include the need for additional steam supply during turbine washing activities, difficulties in condensing steam into water for turbine washing purposes, and the discharge of cooling water from the HE in the turbine washing system directly into the cold basin cooling tower without cooling. These weaknesses disrupt the unit's performance during turbine washing activities, as turbine washing is conducted while the unit is in operation. Based on this background, the author will design a modification route for an alternative hot water source needed for turbine washing, which previously used condensed steam but will now use hot water to condense the steam in the heat exchanger. The design takes into account the existing system with minimal required parameters. The pipe size used is DN 50 mm with ASTM 312 Gr. TP316L material. The total length of the design route is 2.8 m, consisting of one 250 x 50 mm reducer, three 90-degree elbows, and one gate valve used to calculate minor head losses. Stress calculations are performed according to the ASME B31.3 standard for allowable stress limits. The pipe route design results are then modeled in CAESAR 2019 software to verify stress calculations. The stress calculations between manual calculations and simulation results show percentages below the ASME B31.3 standard, specifically 4.3% for sustained load and 3.6% for expansion load. Keywords: pipe, turbine washing, valve, fitting, stress.
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | JBPTPPOLBAN |
Organisasi | |
Nama Kontak | Erlin Arvelina |
Alamat | Jl. Trsn. Gegerkalong Hilir Ds. Ciwaruga |
Kota | Bandung |
Daerah | Jawa Barat |
Negara | Indonesia |
Telepon | 022 201 3789 ext. 168, 169, 239 |
Fax | 022 201 3889 |
E-mail Administrator | erlin.arvelina@polban.ac.id |
E-mail CKO | erlin.arvelina@polban.ac.id |
Print ...
Kontributor...
- Pembimbing 1: Drs. Maridjo, M.T.
Pembimbing 2: Dr. Dra. Sri Widarti, M.Si., M.Sc., Editor: Erlin Arvelina
Download...
File : KELENGKAPAN SKRIPSI - 191724024.pdf
(691143 bytes)
File : BAB 1 - 191724024.pdf
(434843 bytes)
File : BAB 2 - 191724024.pdf
(1130958 bytes)
File : BAB 5 - 191724024.pdf
(394220 bytes)