Perancangan Ulang Kebutuhan Daya Motor Listrik Belt Conveyor 244BC04 Kapasitas 2000 Ton/Jam Area Crusher Tuban 4 di PT. SEMEN INDONESIA
Redesign of Power Requirements of Electric Motor Belt Conveyor 244BC04 Capacity 2000 Tons/Hour Tuban 4 Crusher Area at PT SEMEN INDONESIA (PERSERO) Tbk
Skripsi, 003 / 2023 / TKEUndergraduate Theses from JBPTPPOLBAN / 2024-01-09 10:26:00
Oleh : 191734003 - Auditya Ayuanda Mulyadi (auditya.ayuanda.tken419@polban.ac.id)
Dibuat : 2024-01-09, dengan 4 file
Keyword : Belt Conveyor, Pembebanan, kapasitas daya motor
Subjek : Belt conveyor, load motor, electric motor power capacity
PT.Semen Indonesia di Unit crusher menggunakan belt conveyor sebagai alat transportasi material.penggunaan belt conveyor ini didasari dari kebutuhan kapasitas produksi yang tinggi sehingga dibutuhkan kapasitas pengangkut material yang memiliki kapasitas yang besar. Belt Conveyor 244BC04 ini adalah salah satu unit belt Conveyor yang berada di unit crusher tuban 4 yang bekerja mentransfer material batu kapur dan tanah liat dari unit crusher menuju stock pile. Kapasitas design 244BC04 adalah 2000 ton/jam dengan Panjang lintasan 774 m dan 34 m perbedaan elevasi antara head dan tailnya. Konfigurasi motor yang digunakan adalah dua motor dipasang seri searah dengan arah gerak sabuk. Pada pengoperasiannya arus pembebanan pada kedua motor berada pada nilai 35 %. Hal ini menyebabkan faktor daya rendah. Faktor daya pada kedua motor adalah 0,52. Penurunan efisiensi juga terjadi pada kedua motor yaitu berada di nilai 70,1 %. Upaya yang dilakukan adalah dengan mengubah konfigurasi dua motor menjadi satu motor listrik sehingga pembebanan dapat meningkat. Penentuan kapasitas daya motor listrik yang digunakan dihitung berdasarkan kondisi design Belt Conveyor eksisting dan kapasitas design operasi yaitu 2000 ton/jam. Hasil perancangan ulang daya motor listrik Belt Conveyor 244BC04 dengan konfigurasi satu motor listrik didapat daya motor 130 kW dapat mengoperasikan Belt Conveyor dengan kapasitas 2000 ton/jam. Penghematan energi yang didapat dari penggantian kapasitas motor ini sebesar Rp 10.677.549/bulan atau Rp128.130.593/tahun dengan nilai Payback period selama 6 bulan dan NPV Rp.2.661.968.903. selama10 tahun, Pengoperasikan sesuai dengan kapasitas design yaitu 2000 ton/jam, Kecepatan 2,88 m/s dan efisiensi 95 %. Kata Kunci: Belt Conveyor, Pembebanan, kapasitas daya motor.
Deskripsi Alternatif :PT. Semen Indonesia in the crusher unit uses a belt conveyor as a means of transportation of materials. The use of the belt conveyor is caused by the need for high production capacity so that a large capacity material carrier is needed. This 244BC04 Conveyor Belt is one of the conveyor belt units in the Tuban 4 crusher unit which works to transfer limestone and clay materials from the crusher unit to the stock pile. The design capacity of the 244BC04 is 2000 tons/hour with a track length of 774 m and 34 m difference in height between the head and tail. The motor configuration used is two motors mounted in series in the same direction as the direction of the motion belt. In operation, the loading current on both motors is at a value of 35%. This causes a low power factor, the power factor on both motors is 0.52. The reduction in efficiency also occurs in both motors, which is at a value of 70.1%. The effort is to change the configuration of the two motors into one electric motor so that the load can increase . Controlling the power capacity of the electric motor used is calculated based on the design conditions of the existing Conveyor Belt and the operational design capacity of 2000 tons/hour. The results of redesigning the 244BC04 Belt Conveyor electric motor power with the configuration of one electric motor obtained a motor power of 130 kW that can operate a Conveyor Belt with a capacity of 2000 ton/hour. The energy savings obtained from replacing this motor capacity are Rp. 10.677.549/month or Rp. 128.130.593/year with a payback period of 6 months and an NPV of IDR 2.661.968.903. for one year. by operating according to the design capacity of 2000 tons/hour, Speed of 2.88 m/s and 95 % efficiency. Keywords: Belt conveyor, load motor, electric motor power capacity.
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | JBPTPPOLBAN |
Organisasi | |
Nama Kontak | Erlin Arvelina |
Alamat | Jl. Trsn. Gegerkalong Hilir Ds. Ciwaruga |
Kota | Bandung |
Daerah | Jawa Barat |
Negara | Indonesia |
Telepon | 022 201 3789 ext. 168, 169, 239 |
Fax | 022 201 3889 |
E-mail Administrator | erlin.arvelina@polban.ac.id |
E-mail CKO | erlin.arvelina@polban.ac.id |
Print ...
Kontributor...
- Pembimbing 1: Slameto, S.T., M.Eng.
Pembimbing 2: Drs. Ali Mashar, M.Eng., M.Sc., Editor: Erlin Arvelina
Download...
File : KELENGKAPAN SKRIPSI - 191734003.pdf
(904828 bytes)
File : BAB 1 - 191734003.pdf
(423781 bytes)
File : BAB 2 - 191734003.pdf
(988450 bytes)
File : BAB 5 - 191734003.pdf
(349368 bytes)