Perancangan Unit Sistem Air Cooled Untuk Pre-Cooling AHU Tipe DX di PT Sanbe Farma Unit 1

Design Of Air Cooled System Unit For Pre-Cooling AHU Type DX In PT Sanbe Farma Unit 1

Skripsi, 020 / 2023 / TKE
Undergraduate Theses from JBPTPPOLBAN / 2024-01-09 11:39:54
Oleh : 191734026 - Nurmaya Catur Widayanti (nurmaya.catur.tken419@polban.ac.id)
Dibuat : 2024-01-09, dengan 4 file

Keyword : HVAC, AHU, pre-cooling, Cooling coil, Heating coil
Subjek : HVAC, AHU, pre-cooling, Cooling coil, Heating coil

Sistem HVAC merupakan sistem yang sangat penting dalam sektor industri yang bertujuan untuk mengontrol suhu, kelembaban, dan pendingin udara. Sangat penting untuk menjaga suhu dan kelembaban yang stabil di area produksi. Setiap unit memiliki sistem HVAC yang memenuhi Titik Kendali Mutu (CPOB) dan dilaksanakan secara ketat. Sistem HVAC mencakup beberapa komponen seperti Direct Expansion (DX) dan Chiller yang digunakan untuk mendinginkan koil pendingin di AHU. Di PT Sanbe Farma Unit 1 pada Ruang produksi lantai 3 memproduksi obat non-steril dan memiliki kelas ruangan E menurut standar Cara Pembuatan Obat Yang BaikTemperatur dan kelembapan optimal untuk AHU adalah 20-27°C dan maksimal 70%, sedangkan suhu dan kelembaban eksisting 5 AHU DX di PT adalah 20-27°C dan 50-70%. Untuk mengoptimalkan AHU Tipe DX, digunakan Pre-cooling AHU yang menyuplai AHU serta menjaga suhu dan kelembapan untuk area produksi seluas 37 ruangan. Penelitian ini menggunakan metode kuantitatif untuk menganalisis data dalam proses perencanaan dan analisis. Data primer mengacu pada data yang dikumpulkan dari berbagai sumber, sedangkan data kedua berasal dari literatur dan buku manual. Kapasitas AHU Perubahan temperatur dari 25°C menjadi 20°C dan %RH dari 63,25% menjadi 30% Pre-cooling AHU memiliki koil pendingin sebesar 30.347 kW dan 3.775 kW. 5 unit AHU DX memiliki koil pendingin 30.988 kW, 30.221 kW, 30.114kW, 29.741kW, 30.983kW dan koil pemanas 2.214 kW, 4.318 kW, 4.778 kW, 4.259 kW, 1.511kW. Efektivitas 5 AHU DX adalah 71%, sedangkan efektivitas pre-cooling AHUadalah 73%. Untuk Analisis Ekonomi untuk perancangan pre-cooling AHU payback period 7,11 tahun dan 5 AHU DX 24,85 tahun . Dimana pre-cooling AHU memiliki Payback Period lebih singkat sehingga dipilih penggunaan pre-cooling AHU. Kata Kunci: HVAC, AHU, pre-cooling, Cooling coil, Heating coil.

Deskripsi Alternatif :

The HVAC system is a very important system in the industrial sector which aims to control temperature, humidity and air conditioning. It is very important to maintain a stable temperature and humidity in the production area. Each unit has an HVAC system that meets Quality Control Points (GMP) and is strictly enforced. The HVAC system includes several components such as Direct Expansion (DX) and Chiller which are used to cool the cooling coils in the AHU. At PT Sanbe Farma Unit 1 in the production room on the 3rd floor, it produces non-sterile drugs and has room class E according to the Good Manufacturing Practices standard. The optimal temperature and humidity for AHU is 20-27°C and a maximum of 70%, while the existing temperature and humidity is 5 AHU DX at PT is 20-27°C and 50-70%. To optimize the DX Type AHU, Pre-cooling AHU is used which supplies AHU and maintains temperature and humidity for a production area of 37 rooms. This study uses quantitative methods to analyze data in the process of planning and analysis. Primary data refers to data collected from various sources, while secondary data comes from literature and manuals. AHU Capacity Temperature change from 25°C to 20°C and %RH from 63.25% to 30% Pre-cooling AHU has a cooling coil of 30,347 kW and 3,775 kW. 5 units of AHU DX have cooling coils of 30,988 kW, 30,221 kW, 30,114kW, 29,741kW, 30,983kW and heating coils of 2,214 kW, 4,318 kW, 4,778 kW, 4,259 kW, 1,511kW. The effectiveness of 5 AHU DX is 71%, while the effectiveness of pre-cooling AHU is 73%. For Economic Analysis for designing pre-cooling AHU payback period 7.11 years and 5 AHU DX 24.85 years. Where the pre-cooling AHU has a shorter payback period, so the use of AHU pre-cooling is chosen.. Keywords: HVAC, AHU, pre-cooling, Cooling coil, Heating coil.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakErlin Arvelina
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorerlin.arvelina@polban.ac.id
E-mail CKOerlin.arvelina@polban.ac.id

Print ...

Kontributor...

  • Pembimbing 1: Dr. Dra. Sri Widarti, M.Si., M.Sc.

    Pembimbing 2: Dr. Ir. Sapto Prajogo, M.Si., Editor: Erlin Arvelina

Download...