Path: Top > Tugas Akhir - D3 > Jurusan Teknik Elektro > Program Studi Teknik Listrik > 2014
Rancang Bangun Master Terminal Unit SCADA Berbasis Labview
Design And Implementation Master Terminal Unit SCADA Based On Labview
Tugas Akhir, 037 / 2014 / TLIUndergraduate Theses from JBPTPPOLBAN / 2018-04-25 15:51:16
Oleh : Ade Saepulloh - 111321001 (de_saepulloh@yahoo.com)
Dibuat : 2018-04-25, dengan 4 file
Keyword : SCADA, MTU, HMI, CX-Programmer, RS-232, LabVIEW, OPC Omron Server
Subjek : SCADA, MTU, HMI, the CX-Programmer, RS-232, LabVIEW, Omron OPC Server
Besarnya sumber daya air di Indonesia sangat mendukung pembaharuan sumber energi listrik dengan membangun Pembangkit Listrik Tenaga Mikro Hidro (PLTMH). Dalam ruang lingkup dan jangkauan yang tidak terlalu luas, PLTMH terhubung dalam sebuah jaringan microgrid. Biasanya PLTMH terletak di suatu daerah yang sulit dijangkau. sehingga membutuhkan power electronic interface untuk monitoring dan pengukuran besaran listrik, agar kehandalan jaringan microgrid tetap terjaga dengan baik. Master Terminal Unit (MTU) SCADA digunakan untuk melakukan fungsi telemetering, telesignaling dan telecontroling terhadap plant yang ditampilkan di HMI (Human Machine Interface) berbasis LabVIEW. MTU mengakses data dari RTU dengan media komunikasi serial. Kemudian data diolah dengan menggunakan perangkat lunak CX-Programmer dengan media komunikasi data RS232. Kemudian hasil akusisi data ditampilkan pada LabVIEW yang diakses dari memori data PLC Omron CJ1M. Sehingga HMI LabVIEW dapat mengendalikan dan mengukur tegangan arus, daya, dan frekuensi pada generator secara real time. MTU tersebut dapat melakukan pengukuran pada generator maupun beban seperti yang terukur pada Power Meter secara real time dengan eror rata-rata VRN yaitu -1.1%, VSN sebesar -1.5% dan error VTN sebesar -0.14459%. Error rata-rata IR yaitu 4.815087%, IS sebesar 7.787666% dan error IT sebesar 12.99479%. Sedangkan untuk error rata-rata frekuensi sebesar 0.112348 % dengan delay time 4 detik. Kata kunci: SCADA, MTU, HMI, CX-Programmer, RS-232, LabVIEW, OPC Omron Server.
Deskripsi Alternatif :The amount of water resources in Indonesia is strongly supports renewal energy sources of electricity by building a Micro Hydro Power (MHP). Within the scope and range that is not too broad, MHP connected in a microgrid network. MHP is usually located in an area that is difficult to reach. Thus requiring power electronic interfaces for monitoring and measurement of electrical quantities, in order to microgrid network reliability is maintained properly. Master Terminal Unit (MTU) SCADA systems are used to perform the function of telemetering, telesignaling and telecontroling the plant shown in the HMI (Human Machine Interface) based on LabVIEW. MTU access data from RTU with serial communication media. Then the data were processed using the CX-Programmer software with RS232 data communication media. Then the results displayed in the LabVIEW data acquisition accessed from data memory CJ1M Omron PLC. So that LabVIEW HMI can control and measure the voltage, power, and frequency of the generator in real time. The MTU can perform measurements on the generator and load as measured on the Power Meter in real time with an average error VRN is -1.1%, -1.5% and VSN for VTN error is -0.14459%. IR average error is 4.815087%, 7.787666% for IS and IT at 12.99479% error. As for the average error frequency of 0.112348% to 4 seconds of delay time. Keywords: SCADA, MTU, HMI, the CX-Programmer, RS-232, LabVIEW, Omron OPC Server.
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | JBPTPPOLBAN |
Organisasi | |
Nama Kontak | Erlin Arvelina |
Alamat | Jl. Trsn. Gegerkalong Hilir Ds. Ciwaruga |
Kota | Bandung |
Daerah | Jawa Barat |
Negara | Indonesia |
Telepon | 022 201 3789 ext. 168, 169, 239 |
Fax | 022 201 3889 |
E-mail Administrator | erlin.arvelina@polban.ac.id |
E-mail CKO | erlin.arvelina@polban.ac.id |
Print ...
Kontributor...
- Pembimbing 1: Sarjono Wahyu Jadmiko, S.T., M.Eng.
Pembimbing 2: Drs. Sofian Yahya, S.ST., M.T., Editor: Erlin Arvelina
Download...
File : DAFTAR - 111321001.pdf
(600435 bytes)
File : BAB 1 - 111321001.pdf
(225996 bytes)
File : BAB 2 - 111321001.pdf
(665346 bytes)
File : BAB 5 - 111321001.pdf
(240010 bytes)