Analisis Pengaruh Ukuran Motive Nozzle Ejector Dan Pipa Kapiler Terhadap Kinerja AC Split Menggunakan R-290

An Influence Analysis Of Motive Nozzle Ejector Size And Capillary Tube On Split Air Conditioner Performance Using R-290

Tugas Akhir, 052 / 2014 / RTU
Undergraduate Theses from JBPTPPOLBAN / 2018-04-19 11:45:14
Oleh : Adi Setiana - 111611002 (m.a.setiana@gmail.com)
Dibuat : 2018-04-19, dengan 4 file

Keyword : Ejector Nozzle, Hidrokarbon, Daya listrik, COP
Subjek : Ejector Nozzle, Electricity, Hydrocarbon, COP

Ejector merupakan sebuah throttling device yang sering digunakan pada sistem refrigerasi steam jet. Ejector memiliki saluran hisap yang berfungsi menghisap refrigeran dari evaporator dan mensirkulasikannya kembali ke ejector dan ini bisa mengurangi kerja kompresor yang berlebihan karena refrigeran yang dihisap kembali ke kompresor berfasa gas/uap dgn jumlah yang tidak terlalu banyak. Kinerja ejector sangat dipengaruhi oleh diameter nozzle, oleh karena nozzle ini yang menentukan tinggi rendahnya tekanan di depan nozzle/tekanan keluar nozzle. Disamping itu, Hidrokarbon yang dipakai merupakan refrigeran campuran yang dapat menghemat biaya. Dengan refrigeran hidrokarbon kita bisa mengurangi penggunaan refrigeran yang berlebihan, juga membantu mengamankan lingkungan dari GWP dan ODP. Sehingga COP (Coeficient of Performance) akan lebih maksimal. Dengan menggunakan AC 1 Pk dan Refrigeran R-290, dan memvariasikan ejector COP ejector meningkat sampai 140% dibandingkan dengan nilai COP ketika menggunakan pipa kapiler yang hanya sebesar 5.03. Daya listrik yang dipakai bisa hemat sampai 42% dibandingkan dengan ketika menggunakan pipa kapiler. Kata kunci: Ejector Nozzle, Hidrokarbon, Daya listrik, COP.

Deskripsi Alternatif :

Ejector is a throttling device that used on steam jet refrigeration system. Ejector has a suction line from the evaporator and circulates it back to the ejector and it can be reduced the over work of compressor because the refrigerant through the suction line has become gas with minimum of value. The performance of ejector is depend on the nozzle's diameter, so this is what makes the pressure after the nozzle high or low. Besides that, hydrocarbon that use was a mixed chemical refrigerant but it can reduce the cost and consumption of the electricity. With hydrocarbon we can reduce the value of refrigerant on a system and it can reduce the Global Warming Potential and Ozone Deflection Potential. So then the COP (Coefficient of Performance) can be maximized. With 1 HP air conditioning unit using R290, and variate the ejector's nozzle size it can increase the percentage of COP's value until 140% compared with capillary tube that just only have 5,03. the electricity that consumed can be reduce until 42% compared with capillary tube. Keywords: Ejector Nozzle, Electricity, Hydrocarbon, COP.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakErlin Arvelina
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorerlin.arvelina@polban.ac.id
E-mail CKOerlin.arvelina@polban.ac.id

Print ...

Kontributor...

  • Pembimbing 1: Ir. Sumeru, M.T.

    Pembimbing 2: Susilawati, S.T., M.Eng., Editor: Erlin Arvelina

Download...