Path: Top > Skripsi - D4 > 2017 > Jurusan Teknik Konversi Energi > Program Studi Teknologi Pembangkit Tenaga Listrik > 2017
Rancangan Combustor Low NOx Untuk Sistem Pusat Listrik Tenaga Gas
The Design Of Combustor Low NOx For Gas Power Plant System
Tugas Akhir, 003 / 2017 / TPTLUndergraduate Theses from JBPTPPOLBAN / 2018-09-03 15:05:18
Oleh : Agum Raksagumilang - 131724003 (agumraksa@gmail.com)
Dibuat : 2017-10-27, dengan 4 file
Keyword : Turbin Gas, GE-DLN, Pembakaran, Emisi NOX, ANSYS FLUENT, ANSYS CHEMKIN
Subjek : Gas Turbine, GE-DLN, Combustion, NOX Emissions, ANSYS FLUENT, ANSYS CHEMKIN
Combustor atau ruang bakar memiliki fungsi sebagai tempat terjadinya pembakaran pada Pusat Listrik Tenaga Gas (PLTG). Hasil pembakaran tersebut akan meningkatkan temperatur, kecepatan, dan volume dari aliran gas yang kemudian akan memutar turbin gas. Namun proses tersebut memilki dampak terhadap lingkungan, dengan adanya emisi yang dikeluarkan dari hasil pembakaran. Sehingga rancangan dari combustor tersebut menjadi perhatian utama, termasuk volume ruang bakar. Perubahan volume dilakukan untuk melihat perubahan terhadap emisi NOX. Turbin gas yang digunakan adalah milik GE dengan tipe 6B.03 berkapasitas 44 MW yang memilki sistem Dry-Low Emission (DLE). Dengan ukuran volume pada Rancangan 1, volume yang dibesarkan pada Rancangan 2, dan volume yang dikecilkan pada Rancangan 3 menghasilkan Emisi NOX yang terdiri dari kandungan NO dan NO2 yang hasilnya berbeda di tiap rancangan. Rancangan 1 memilki emisi NOX dengan nilai 0,42 ppmvd pada 15% O2, Rancangan 2 memiliki nilai 1,02 ppmvd pada 15% O2, dan Rancangan 3 memiliki nilai 0,44 ppmvd pada 15% O2. Perbedaan nilai tersebut dikarnakan ketika volume dirubah bukan hanya dimensinya saja yang berubah, namun aliran udara yang terjadi di dalam combustor ikut berubah, yang artinya akan merubah distribusi temperatur yang terjadi di dalam combustor, ini disimulasikan menggunakan ANSYS FLUENT. Tentunya perubahan distribusi temperatur tersebut sangat berpengaruh terhadap reaksi pembakaran di dalam combustor, yang akan berperngaruh terhadap pembentukan emisi NOX. NOX terbentuk di zona-zona pembakaran yang berada didalam combustor. Zona-zona tersebut dimodelkan dengan reaktor kimia mengunakan ANSYS CHEMKIN. Emisi NOX lebih sering terbentuk dari N2 dan O2 yang terkandung dalam udara yang dibutuhkan dalam pembakaran. Kata kunci : Turbin Gas, GE-DLN, Pembakaran, Emisi NOX, Ansys Fluent, Ansys Chemkin.
Deskripsi Alternatif :Combustor or combustion chamber has a function as a place of combustion at the Gas Power Plant. The combustion results will increase the temperature, velocity, and volume of the gas stream which will rotate the gas turbine. But the process has an impact on the environment, there is emissions released from combustion. So the design of the combustor is a major concern, including the volume of the combustion chamber. Volume changes made to see changes of NOX emissions. The gas turbine used is owned by GE with a type of 6B.03 with a capacity of 44 MW which has a Dry-Low Emission (DLE) system. With the volume size in Design 1, the raised volume in Design 2, and the reduced volume of Design 3, produce NOX Emissions consisting of NO and NO2 with different results in each design. Design 1 has NOX emissions of 0.42 ppmvd at 15% O2, Design 2 has a value of 1.02 ppmvd at 15% O2, and Design 3 has a value of 0.44 ppmvd at 15% O2. The difference in value is denoted when the volume is changed not only the dimensions are changed but the airflow that occurs inside the combustor also changes, which means it will change the temperature distribution, occurring inside combustor that simulated using ANSYS FLUENT. Of course the temperature distribution change is very influential on combustion reactions in the combustor, which will affect the formation of NOX emissions. NOX formed in the combustion zones in the combustor, the zones are modeled with a chemical reactor using ANSYS CHEMKIN. NOX emissions are more commonly formed from N2 and O2 contained in the air which required in combustion. Keywords: Gas Turbine, GE-DLN, Combustion, NOX Emissions, ANSYS FLUENT, ANSYS CHEMKIN.
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | JBPTPPOLBAN |
Organisasi | |
Nama Kontak | Erlin Arvelina |
Alamat | Jl. Trsn. Gegerkalong Hilir Ds. Ciwaruga |
Kota | Bandung |
Daerah | Jawa Barat |
Negara | Indonesia |
Telepon | 022 201 3789 ext. 168, 169, 239 |
Fax | 022 201 3889 |
E-mail Administrator | erlin.arvelina@polban.ac.id |
E-mail CKO | erlin.arvelina@polban.ac.id |
Print ...
Kontributor...
- Pembimbing 1: Ir. Teguh Sasono, M.T.
Pembimbing 2: Arya Wulung, S.T., M.T., Editor: Erlin Arvelina
Download...
File : KELENGKAPAN TA - 131724003.pdf
(1173591 bytes)
File : BAB 1 - 131724003.pdf
(109575 bytes)
File : BAB 2 - 131724003.pdf
(580687 bytes)
File : BAB 5 - 131724003.pdf
(133803 bytes)