Path: Top > Tugas Akhir - D3 > Jurusan Teknik Refrigerasi dan Tata Udara > Program Studi Teknik Refrigerasi dan Tata Udara > 2013
Rancang Bangun Ulang Sistem Refrigerasi Kompresi Uap dengan menggunakan Secondary Refrigerant untuk Produk Sayuran
Redesign of Vapour Compression Refrigeration System using Secondary Refrigerant for Vegetables Product
Tugas Akhir, 037 / 2013 / RTUUndergraduate Theses from JBPTPPOLBAN / 2017-04-13 14:10:57
Oleh : Agung Subagja - 101611033 (Agungsubagja100@gmail.com)
Dibuat : 2017-04-13, dengan 4 file
Keyword : Rancang bangun ulang, sistem refrigerasi kompresi uap, ethylene glycol
Subjek : Redesain, vapour compresion sistem, ethylene glycol
Perkembangan ilmu pengetahuan dan teknologi di berbagai bidang yang begitu pesat dengan peralatan yang semakin cangggih, dimana metode penerapan refrigeran sekunder ini dipilih dengan dasar pertimbangan untuk mengoptimalkan konsumsi energi terpakai sehingga dapat dialih gunakan untuk kepentingan yang lain, dalam karya ilmiah tugas akhir ini dipilih ethylene glycol sebagai media refrigerant sekunder dengan alasan memiliki sifat-sifat yang dapat mendukung fungsinya sebagai refrigeran sekunder, dengan menggunakan refrigerant sekunder ini diharapkan sistem refrigerasi ini dapat mengoptimalkan energi yang ada supaya energi yang ada tidak terbuang dengan percuma dan dapat hemat energi. Kajian yang dilakukan adalah dengan membuat prototype mesin refrigerasi penyimpan produk sayuran dengan metode pendinginan tak langsung menggunakan refrigeran sekunder berupa campuran 30% ethylene glycol dan 70% air yang dialirkan ke ruangan penyimpan produk. Setelah dilakukan analisis maka didapat nilaiCOPaktual 3,65 , COPCarnot 4,81 sehingga didapat Efisiensinya 75%, temperatur kabin yang dapat dicapai yaitu 4,2⁰C, dengan chilling time yang didapat 180 menit.dan konsumsi energi yang digunakan sebesar 1,1 KW selama sistem menyala dalam waktu 400 menit. Kata kunci: Rancang bangun ulang, sistem refrigerasi kompresi uap, ethylene glycol.
Deskripsi Alternatif :The development of science and technology in various field is so rapidly with the modern equipment, where the method of applying a secondary refrigeration has been the basis of considerations to optimize the energy consumption selected to so it can be converted to use for the benefit to others, the final project has been ethylene glycol as a secondary refrigerant which having properties that can support its function as a secondary refrigerant, using the secondary refrigerant, the refrigeration system is expected to optimize the existing energy so that the energy is not wasted and can be efficient. the study is to make the prototype of refrigeration storage of vegetables with indirect cooling method using a secondary refrigerant mixture of 30% ethylene glycol and 70% water that flowed into the wall storage the products. After analyzing the obtained actual coefficient of performance of 3.65,and carnot coefficient of performance 4.81 so Efficiencies gained 75%, which can achieved cabin temperature of 4.2⁰C, with chilling time of 180 minutes. and energy consumption of 1.1 KW is used for the system to 400 minutes. Keyword: Redesain, vapour compresion sistem, ethylene glycol.
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | JBPTPPOLBAN |
Organisasi | |
Nama Kontak | Erlin Arvelina |
Alamat | Jl. Trsn. Gegerkalong Hilir Ds. Ciwaruga |
Kota | Bandung |
Daerah | Jawa Barat |
Negara | Indonesia |
Telepon | 022 201 3789 ext. 168, 169, 239 |
Fax | 022 201 3889 |
E-mail Administrator | erlin.arvelina@polban.ac.id |
E-mail CKO | erlin.arvelina@polban.ac.id |
Print ...
Kontributor...
- Pembimbing 1: Triaji Pangripto Pramudantoro, S.T., M.Eng.
Pembimbing 2: A. P. Edi Sukamto, S.T., M.T., Editor: Erlin Arvelina