ANALISIS PERFORMANSI PADA SISTEM REFRIGERASI TAK LANGSUNG AKIBAT PERUBAHAN KONSENTRASI REFRIGERAN SEKUNDER JENIS CAMPURAN ETHYLENE GLYCOL & AIR

PERFORMANCE ANALYSIS OF INDIRECT REFRIGERATION SYSTEM DUE TO CHANGES OF SECONDARY REFRIGERANT CONSENTRATE VARIATION OF ETHYLENE GLYCOL & WATER

Tugas Akhir, 031 / 2012 / RTU
Undergraduate Theses from JBPTPPOLBAN / 2014-07-04 10:27:41
Oleh : Ahmad Ramana Raskofa Putra - 091611003 (mr.arethusa@gmail.com)
Dibuat : 2014-07-04, dengan 4 file

Keyword : Indirect Cooling, Secondary Refrigerant, ChillingTime, COP, Efisiensi
Subjek : Indirect Cooling, Secondary Refrigerant, Chilling Time, COP, Efficiency

Sistem indirect cooling dengan secondary refrigerant merupakan proses pendinginan fluida dari campuran Ethylene Glycol dan air yang disirkulasikan menuju kabin atau produk yang didinginkan. Tujuan dari penulisan ini yaitu menganalisa performansi sistem refrigerasi dengan secondary refrigerant campuran Ethylene Glycol dan air, dilihat dari COP sistem dan efisiensi di tiap konsentrasi, mengetahui perbandingan temperatur yang dicapai oleh kabin dan mengetahui chilling time dan temperatur pada tangki bagian dalam yang dapat dicapai di tiap konsentrasi. Proses indirect cooling dengan secondary refrigerant tersebut menggunakan kompresor jenis reciprocating dengan kapasitas 1/3 PK dan perbandingan konsentrasi Ethylene Glycol 10%, 20% dan 30%, serta menggunakan beban produk berupa brokoli. Berdasarkan dari hasil pengukuran, temperature akhir kabin yang dicapai adalah 6.6°C (pada konsentrasi 10%) serta chilling time yang dapat dicapai pada menit ke-60 (konsentrasi 10%) dan menit ke-70 (konsentrasi 20% dan 30%). Nilai rata-rata COP yang dapat dicapai oleh sistem dengan campuran konsentrasi 10% Ethylene Glycol adalah sebesar 3,56 dengan efisiensi 67,8%, sementara sistem dengan konsentrasi 20% Ethylene Glycol adalah sebesar 3,58 dengan efisiensi 67,9% dan untuk sistem dengan konsentrasi 30% Ethylene Glycol adalah 3,67 dengan efisiensi 68%. Kata Kunci: Indirect Cooling, Secondary Refrigerant, Chilling Time, COP, Efisiensi.

Deskripsi Alternatif :

Indirect cooling system with secondary refrigerant is a cooling of fluid from a mixture of Ethylene Glycol and water which is circulated into the cabin or refrigerated products. The purpose of this final project is to analyze the performance of secondary refrigeration system refrigerant mixture of Ethylene Glycol and water, seen from the COP and system efficiency at each the concentration, knowing the comparison temperature reached by the cabin and Knowing the chilling time and the temperature on the inside of the tank that can be achieved in each concentration. Indirect cooling process with a secondary refrigerant uses reciprocating compressor with a capacity of 1/3 HP and a variation of the concentration Ethylene Glycol of 10%, 20% and 30%, as well as uses broccoli as a product load. Based on the results of measurements, the temperature reached at the cabin is 6.6°C (concentrate 10%) and the chilling time is reached at 60 minutes (concentration 10%) and 70 minutes (concentration of 20% and 30%). The average value of COP that can be achieved by system with a mixture of Ethylene Glycol concentrate of 10% is 3.56 with efficiency of 67.8%, while the system with a concentrate of 20% Ethylene Glycol is 3.58 with efficiency of 67.9% and the system with aconcentrate of 30% Ethylene Glycol is 3.67 with efficiency of 68%. Keywords: Indirect Cooling, Secondary Refrigerant, Chilling Time, COP, Efficiency.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakErlin Arvelina
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorerlin.arvelina@polban.ac.id
E-mail CKOerlin.arvelina@polban.ac.id

Print ...

Kontributor...

  • Pembimbing 1: Nur Khakim, ST., M.Sc.

    Pembimbing 2: Triaji Pangripto Pramudantoro, ST., M.Eng.
    , Editor: Erlin Arvelina

Download...