RANCANG BANGUN MODUL PRAKTIKUM PROTEKSI SISTEM 3 FASA RELAY TEGANGAN KURANG MENGGUNAKAN RELAY TIPE BE4-27/59
DESIGN AND BUILD 3 PHASE SYSTEM PRACTICAL MODULE PROTECTION UNDERVOLTAGE RELAY USING BE4-27/59
Tugas Akhir, 041 / 2012 / TLIUndergraduate Theses from JBPTPPOLBAN / 2015-11-18 09:21:47
Oleh : Ahmad Salman Farizi - 091321065
Dibuat : 2013-05-07, dengan 4 file
Keyword : Gangguan Tegangan Kurang, Relay Tegangan Kurang, Relay Tegangan Kurang tipe BE4-27/59
Subjek : undervoltage fault, undervoltage relay, undervoltage relay BE4-27/59 type
Tegangan kurang adalah suatu gangguan dimana telah terjadi penurunan tegangan dari tegangan nominal dalam waktu yang relatif lama. Tegangan kurang dapat terjadi karena adanya gangguan di pembangkit sehingga terus berlanjut sampai ke beban. Akibatnya dapat berakibat fatal terhadap beban. Oleh karena itu diperlukan suatu pengaman yang dapat menghentikan gangguan tersebut. Dan alat untuk dapat mendeteksi gangguan tegangan kurang adalah relay tegangan kurang. Relay tegangan kurang adalah relay yang bekerja dengan menggunakan tegangan sebagai besaran ukur. Relay akan bekerja jika mendeteksi adanya penurunan tegangan yang melampaui batas yang telah ditentukan sebelumnya. Ketika tegangan melebihi tegangan setting maka relay akan mengaktifkan rangkaian tripping coil sehingga akan menarik kontak PMT menjadi terbuka dan suplai akan terputus sehingga beban aman dari gangguan tegangan kurang. Relay tegangan kurang tipe BE4-27/59 bekerja pada tegangan 380 volt serta memiliki tegangan setting yang dapat diatur dan bervariasi dimulai dari 75%, 80%, 85%, 90%, dan 95%. Relay ini memiliki persentase error pembacaan gangguan tegangan kurang sebesar kurang lebih 3%. Pengujian yang dilakukan terhadap relay tegangan kurang tipe BE4-27/59 ini ditujukan untuk mengetahui kerja dari relay tersebut dalam mengatasi gangguan tegangan kurang, mengetahui tegangan kerja berdasarkan pengujian dan mengetahui persentase error pembacaan gangguan tegangan kurang. Kata Kunci: Gangguan Tegangan Kurang, Relay Tegangan Kurang, Relay Tegangan Kurang tipe BE4-27/59
Deskripsi Alternatif :Undervoltage is a fault in which there has been a drop in voltage from the nominal voltage in a relatively long time. Undervoltage may occur due to a fault in the power plant so that it continues to load. The consequences can be fatal to the load. It is therefore necessary to have a protection to stop the fault. And tools to detect disturbance voltage is a undervoltage relays.
Undervoltage relay will working using voltage as a quantity measurement. The relay will work if it detects a drop in voltage that exceeds the limit that has been set before. When a voltage exceeding the voltage setting then relay will activate a series of tripping coil so it will pull the PMT contact to save a load from undervoltage fault.
Undervoltage relay type BE4-27/59 is working at 380 volt and voltage setting can be adjustable variously from 75% to 95% in a 5% interval. The relay has a percentage error reading voltage disturbance more than less 3%.
Testing is done on undervoltage relay type BE4-27/59 is intended to find out the work of overcoming the interference relay in undervoltage, knowing the working voltage based on testing and knowing the percentage error reading undervoltage fault.
Keywords: undervoltage fault, undervoltage relay, undervoltage relay BE4-27/59 type
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | JBPTPPOLBAN |
Organisasi | |
Nama Kontak | Erlin Arvelina |
Alamat | Jl. Trsn. Gegerkalong Hilir Ds. Ciwaruga |
Kota | Bandung |
Daerah | Jawa Barat |
Negara | Indonesia |
Telepon | 022 201 3789 ext. 168, 169, 239 |
Fax | 022 201 3889 |
E-mail Administrator | erlin.arvelina@polban.ac.id |
E-mail CKO | erlin.arvelina@polban.ac.id |
Print ...
Kontributor...
- Pembimbing 1: Dwi Asmono, Drs., M.Pd.
Pembimbing 2: Dadang Hidayat, Ir. , Editor: Erlin Arvelina
Download...
File : DAFTAR - 091321065.pdf
(235973 bytes)
File : BAB 1 - 091321065.pdf
(175346 bytes)
File : BAB 2 - 091321065.pdf
(459504 bytes)
File : BAB 5 - 091321065.pdf
(172614 bytes)