Path: Top > Skripsi - D4 > 2017 > Jurusan Teknik Konversi Energi > Program Studi Teknik Konservasi Energi > 2021
Rancang Inverter 5-Level Cascaded H-Bridge Untuk PLTS on Grid dengan Kapasitas Beban 25 kW
Design of 5-Level Cascaded H-Bridge Inverter for On-Grid Solar Power Plant with 25 kW Load Capacity
Skripsi, 004 / 2021 / TKEUndergraduate Theses from JBPTPPOLBAN / 2022-12-28 10:24:43
Oleh : Aini Mutiara Syabani - 171734002 (amutiarasyabani@gmail.com)
Dibuat : 2022-12-28, dengan 4 file
Keyword : Inverter, Cascade H-Bridge 5-Level, Harmonisa, Rugi-rugi
Subjek : inverter, cascaded H-bridge 5-Level, Harmonics, Losses
Pembangkitan listrik tenaga surya menghasilkan listrik DC, agar dapat dimanfaatkan pada barang elektronik membutuhkan catu daya AC, dibutuhkan inverter untuk mengonversi listrik DC menjadi AC. Harmonisa merupakan distorsi gelombang pada output inverter yang disebabkan pembentukan gelombang dengan frekuensi kelipatan dari frekuensi fundamental (50 Hz). Harmonisa ini dapat mengakibatkan overheat pada alat elektronik yang dicatudayai, selain alat elektronik memiliki batas maksimum harmonisa yaitu 5%. Salah satu upaya reduksi harmonisa dapat dilakukan dengan menggunakan topologi inverter multilevel. Rancangan inverter topologi 5-Level Cascaded H-bridge (CHB 5-Level) berfungsi untuk mengubah tegangan DC 179 V menjadi tegangan 220 V untuk beban delta 25 kW. Inverter ini menggunakan saklar IGBT dan metode penyaklaran PWM Level ShiftedâIn Phase Dispostition dengan frekuensi switching 320 Hz. Pada frekuensi switching 1 kHz inverter CHB 5-Level dapat mereduksi harmonisa 51.7% dibandingkan dengan inverter 3-Level Bridge. Untuk menghasilkan THD 5%, inverter CHB 5-Level dioperasikan dengan frekuensi switching 320 Hz sedangkan inverter 3-Level Bridge 525 Hz. Frekuensi kerja yang lebih rendah dapat mengurangi rugi-rugi switching dan konduksi pada saklar (transistor).
Deskripsi Alternatif :Solar power generation produces DC electricity used in electronic goods that require an AC power supply. An inverter is needed to convert DC electricity to AC. Harmonic is a distortion of a wave caused by the formation of the waves whose frequency is multiple of the fundamental frequency (50 Hz). The harmonic limit is 5%, if it's larger than that it will cause unwanted heat in the electronic device. One of the harmonic reduction methods is using a multilevel inverter topology. The design of the 5-Level Cascaded H-bridge topology inverter (CHB 5-Level) serves to convert a DC voltage of 89.75 V to a voltage of 220 V for a delta load of 25 kW. This inverter uses an IGBT switch and a PWM Level Shifted In Phase Disposition switching method with a switching frequency of 320 Hz. At a switching frequency of 1 kHz, the 5-Level CHB inverter can reduce harmonics by 51.7% compared to the 3-Level Bridge inverter. There are different switching frequency settings to achieve 5% THD for the topologies, for the 3-Level Bridge inverter requires 525 Hz while the 5-Level CHB inverter requires a lower switching frequency, 320 Hz. Lower operating frequency can reduce switching and conduction losses in the switch (transistor).
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | JBPTPPOLBAN |
Organisasi | |
Nama Kontak | Erlin Arvelina |
Alamat | Jl. Trsn. Gegerkalong Hilir Ds. Ciwaruga |
Kota | Bandung |
Daerah | Jawa Barat |
Negara | Indonesia |
Telepon | 022 201 3789 ext. 168, 169, 239 |
Fax | 022 201 3889 |
E-mail Administrator | erlin.arvelina@polban.ac.id |
E-mail CKO | erlin.arvelina@polban.ac.id |
Print ...
Kontributor...
- Pembimbing 1: Dr. I Made Wiwit Kastawan, M.T.
Pembimbing 2: Siti Saodah, S.T., M.T., Editor: Erlin Arvelina
Download...
File : KELENGKAPAN SKRIPSI - 171734002.pdf
(811679 bytes)
File : BAB 1 - 171734002.pdf
(187088 bytes)
File : BAB 2 - 171734002.pdf
(926753 bytes)
File : BAB 5 - 171734002.pdf
(29816 bytes)