RANCANG BANGUN MODUL PRAKTIKUM RELAY TEGANGAN LEBIH SISTEM 3 FASA MENGGUNAKAN RELAY TIPE BE4-27/59
DESIGN AND IMPLEMENTATION OVERVOLTAGE RELAY 3 PHASE SYSTEM USING RELAY TYPE BE4-27/59 PRACTICAL MODULE
Tugas Akhir, 043 / 2012 / TLIUndergraduate Theses from JBPTPPOLBAN / 2015-11-18 09:21:48
Oleh : Akbar Agung Azhari - 091321038
Dibuat : 2013-05-07, dengan 4 file
Keyword : Ganguan tegangan lebih, relay tegangan lebih, setting tegangan
Subjek : overvoltage interference, overvoltage relay, voltage setting
Kestabilan catu daya listrik dalam suatu sistem rangkaian listrik sangat diperlukan. Adanya gangguan dalam catu daya listrik dapat mempengaruhi bahkan merusak suatu sistem rangkaian listrik. Gangguan yang dapat terjadi antara lain adalah adanya over voltage atau tegangan lebih. Salah satu cara untuk mengatasi hal tersebut adalah dengan menggunakan alat pengaman yaitu relay tegangan lebih. Relay ini digunakan untuk mendeteksi adanya over voltage. Output dari relay dapat dihubungkan pada rangkaian pemutus untuk memutuskan aliran listrik jika terjadi gangguan. Maka dari itu penulis merancang suatu modul praktikum yang bertujuan untuk mendeteksi adanya over voltage pada tegangan 3 fasa 380V 50 Hz. Relay tegangan lebih bekerja berdasarkan kenaikan tegangan yang mencapai atau melebihi nilai settingnya. Untuk melihat relay bekerja dengan baik adalah dengan cara melakukan pengujian pada setiap nilai setting tegangannya apakah bekerja dengan baik atau tidak. Salah satu contoh data pengujian di setting tegangan 105%, dalam hal ini relay seharusnya bekerja saat tegangan naik atau mencapai lebih dari 5% dari tegangan nominal. Dari hasil pengujian yang dilakukan, relay bekerja dengan baik dengan memberikan sinyal kepada PMT untuk memutuskan jaringan pada saat tegangan naik mencapai 5% dari tegangan nominal dengan waktu pemutusan dari 3 hingga 2,57 detik. Begitupun di nilai setting yang lain, relay bekerja dengan baik sesuai dengan nilai setting tegangannya. Kata kunci: Ganguan tegangan lebih, relay tegangan lebih, setting tegangan
Deskripsi Alternatif :The stability of the electrical power supply circuit in an electrical system is needed. An interruption in electrical power supply can affect even damage an electrical circuit system. One of Interference that may occur is the presence of over voltage. One way to overcome it is to use a safety device which is overvoltage relay. This relay is use to detect the presence of over voltage. The output of this relay can be connected to the circuit breaker to terminate power when disruption happen. Thus the authors designed a practical module which aims to detect the presence of over voltage to the voltage 3 phase 380V 50 Hz. Voltage relay works better based on the rising voltage over the set value. To see the relay works well is by doing test at each value of the voltage setting, is it work properly or not. One example of test data at 105% voltage setting, in this case the relay is supposed to work when the voltage rises or reach more than 5% from the nominal voltage. Based on the test, the relay works well by give signal to the PMT to disconnect the network when the voltage rises to 5% of nominal voltage with a time of disconnection time from 3 to 2.57 seconds. Likewise in the other setting, the relay works well in accordance with the voltage setting value. Keyword : overvoltage interference, overvoltage relay, voltage setting
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | JBPTPPOLBAN |
Organisasi | |
Nama Kontak | Erlin Arvelina |
Alamat | Jl. Trsn. Gegerkalong Hilir Ds. Ciwaruga |
Kota | Bandung |
Daerah | Jawa Barat |
Negara | Indonesia |
Telepon | 022 201 3789 ext. 168, 169, 239 |
Fax | 022 201 3889 |
E-mail Administrator | erlin.arvelina@polban.ac.id |
E-mail CKO | erlin.arvelina@polban.ac.id |
Print ...
Kontributor...
- Pembimbing 1: Dwi Asmono, Drs., M.Pd.
Pembimbing 2: Dadang Hidayat, Ir. , Editor: Erlin Arvelina
Download...
File : DAFTAR - 091321038.pdf
(848797 bytes)
File : BAB 1 - 091321038.pdf
(168632 bytes)
File : BAB 2 - 091321038.pdf
(344774 bytes)
File : BAB 4 - 091321038.pdf
(487157 bytes)