Path: Top > Skripsi - D4 > 2017 > Jurusan Teknik Konversi Energi > Program Studi Teknologi Pembangkit Tenaga Listrik > 2020

Perancangan HRSG Tipe Natural Circulating Tekanan Dua Tingkat Di PLTGU Muara Tawar Kapasitas 220MW

Design of Natural Circulating HRSG Double Pressure System at PLTGU Muara Tawar 220MW

Skripsi, 003 / 2020 / TPTL
Undergraduate Theses from JBPTPPOLBAN / 2022-04-01 11:16:08
Oleh : Alqowi Rizal - 161724001 (alqowi97@gmai.com)
Dibuat : 2022-04-01, dengan 4 file

Keyword : Evaporator, Economizer, Heat Recovery Steam Generator, PLTGU, PLTG, PLTU, Superheater, Tekanan Dua Tingkat
Subjek : PLTGU, HRSG, economizer, evaporator, superheater

Pembangkit Listrik Tenaga Gas dan Uap (PLTGU) merupakan pembangkit listrik yang menggabungkan dua siklus yaitu siklus Brayton (PLTG) dan siklus rankine (PLTU). dimana siklus Rankine (PLTU) terjadi dengan memanfaatkan gas buang dari siklus Brayton (PLTG) dengan temperatur gas buang keluaran PLTG ini adalah 520-605 oC yang dimanfaatkan untuk menghasilkan uap pada PLTU dengan menggunakan Heat Recovery Steam Generator untuk menghasilkan uap superheat, dimana Heat Recovery Steam Generator ini terdiri dari Ekonomiser, Evaporator dan Superheater. Pada laporan tugas akhir ini dilakukan rancangan pada komponen-komponen tersebut pada sistem tekanan dua tingkat yaitu 68 bar dan 2 bar. Setelah dilakukan perancangan didapatkan dimensi komponen-komponen tersebut diantaranya panjang pipa, diameter luar pipa, diameter dalam pipa, tebal pipa dengan BWG masing-masing komponen tersebut. Pada PLTGU ini beban PLTG tidak akan selamanya konstan dilakukan menggunakan software Gatecycle dengan perubahan beban PLTG sebesar 100%, 90%, 80%, 70%, dan 60%. Dimana seiring penurunan beban PLTG yang menyebabkan penurunan pada laju alir masa gas buang, laju air masa air umpan, temperatur gas buang, daya keluaran PLTU dan PLTGU, Kemudian tebal pipa yang dirancang melebihi dari tebal pipa minimal supaya dapat bertahan pada temperatur yang ditentukan. Kata Kunci: Evaporator, Economizer, Heat Recovery Steam Generator, PLTGU, PLTG, PLTU, Superheater, Tekanan Dua Tingkat.

Deskripsi Alternatif :

Combined Cycle Power Plant (PLTGU) is a power plant that combine two cycles that is brayton cycle (PLTG) and rankine cycle (PLTU), which rankine cycle is occurred using wasted gas from Brayton Cycle with 500-590 oC as the temperature of wasted gas from PLTG. This wasted gas is used to produce steam in PLTU using HRSG for producing superheat steam, which this HRSG is economizer, evaporator, and superheater as the component, this component will be design with two stage pressure system is 68 and 2 bar. After designing, dimension of the component such as tube length, tube outside diameter, tube inside diameter, tube thickness with BWG for each component will be obtained. In this PLTGU, the PLTG load will not be carried out forever using the Gatecycle software with changes in the PLTG load of 100%, 90%, 80%, 70%, and 60%. Where as the PLTG load decreases which causes a decrease in the mass flow rate of the exhaust gas, the feed mass air flow rate, the exhaust gas temperature, the PLTU and PLTGU output power, then the designed pipe thickness exceeds the minimum pipe thickness that can withstand the specified temperature. Keywords: PLTGU, HRSG, economizer, evaporator, superheater.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakErlin Arvelina
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorerlin.arvelina@polban.ac.id
E-mail CKOerlin.arvelina@polban.ac.id

Print ...

Kontributor...

  • Pembimbing 1: Bambang Puguh Manunggal, S.T., M.Eng.

    Pembimbing 2: Dr. Ir. Sri Wuryanti, M.Si., Editor: Erlin Arvelina

Download...