Path: Top > Tugas Akhir - D3 > Jurusan Teknik Refrigerasi dan Tata Udara > Program Studi Teknik Refrigerasi dan Tata Udara > 2014
Rancang Bangun Alat Pengontrol Ketinggian Air Dan Monitoring Temperatur Pada Sistem Steam Jet Dengan Menggunakan Arduino Uno R3
Design And Construct Of Control Device Water Level And Monitoring Of Temperature Steam Jet System Based On Arduino Uno R3
Tugas Akhir, 056 / 2014 / RTUUndergraduate Theses from JBPTPPOLBAN / 2018-04-19 11:31:36
Oleh : Anggi Andini Permata Putri - 111611040 (anggiandinipp@gmail.com)
Dibuat : 2018-04-19, dengan 4 file
Keyword : close-loop, steam jet, evaporator, make up water, photoelectric, LCD, data logger, Arduino Uno R3, setpoint, DS18B20, thermocouple, condensser
Subjek : close-loop, steam jet, evaporator, make up water, photoelectric, LCD, data logger, Arduino Uno R3, setpoint, DS18B20, thermocouple, condensser
Seiring dengan perkembangan zaman teknologi yang semakin maju membuat segala hal menjadi semakin praktis salah satunya adalah dengan menambahkan alat pengontrol. Alat pengontrol merupakan elemen penting dari suatu sistem close-loop, salah satu aplikasi pengontrolan close-loop adalah pada sistem steam jet. Steam jet memiliki evaporator yang memerlukan make up water pada proses pendinginannya. Air pada evaporator dijaga sedemikian rupa agar kapasitasnya cukup karena tinggi dan rendahnya air berpengaruh besar pada hasil pendinginan, alat pengontrol ketinggian air yang digunakan adalah dengan menggunakan prinsip photoelectric. Selain itu untuk mempermudah proses pengambilan data maka pada sistem steam jet ditambahkan alat monitoring temperatur secara langsung berupa LCD dan tidak langsung berupa Data Logger. Hasil yang didapat dari tugas akhir ini adalah sistem kontrol dengan menggunakan Arduino Uno R3 dapat digunakan sebagai alat bantu proses on/off pada pompa, namun hasil yang didapatkan kurang maksimal, ini dibuktikan dengan ketinggian air yang tidak stabil dan sangat menjauhi nilai setpoint. Perbedaan terbesar tinggi air pada saat pompa dalam kondisi off yaitu sebesar 6,1 cm dan perbedaan terbesar tinggi air pada saat pompa dalam kondisi on yaitu 2 cm. Sedangkan pada sensor temperatur DS18B20 memiliki hasil pengukuran yang baik ini dibuktikan dengan kecilnya perbedaan selisih temperatur antara DS18B20 dengan thermocouple, selisih terbesar yaitu 1⁰C pada pengukuran temperatur lingkungan percobaan 3 dengan standar deviasi 0.12±0.331 dan standar error 0.12±0.125. Kata kunci : close-loop, steam jet, evaporator, make up water, photoelectric, LCD, data logger, Arduino Uno R3, setpoint, DS18B20, thermocouple, condensser.
Deskripsi Alternatif :By the time being, the advanced technology makes things more practical, which is by adding a controller. Control equipment is an essential element of a closed-loop system, which is applied to a steam jet refrigeration system. Steam jets have evaporators that require make-up water in the cooling process. The level of the water on the evaporator is maintained such that sufficient capacity for high and low water have great impact on the results of cooling, which water level control device used is to use the photoelectric principle. In addition, to simplify the process of collecting data on the steam jet system is by adding a direct temperature monitoring devices such as LCD and indirectly in the form of Data Logger. The results of this thesis is the control system using the Arduino Uno R3 which can be used as process aids on / off switch on the pump, but the results obtained are less than the maximum height of the water which is evidenced by an unstable and very away from the setpoint value. The biggest difference when the water level in the pump off condition that is equal to 6.1 cm while the largest difference in height of water at the pump in a condition on that is 2 cm. For the DS18B20 temperature sensor has a good measurement result is evidenced by the small differences in the temperature difference between the thermocouple DS18B20, the biggest difference is 1⁰C at ambient temperature measurement experiment 3 with standar deviasi is 0.12±0.331 and standar error is 0.12±0.125. Keywords: close-loop, steam jet, evaporator, make up water, photoelectric, LCD, data logger, Arduino Uno R3, setpoint, DS18B20, thermocouple, condensser.
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | JBPTPPOLBAN |
Organisasi | |
Nama Kontak | Erlin Arvelina |
Alamat | Jl. Trsn. Gegerkalong Hilir Ds. Ciwaruga |
Kota | Bandung |
Daerah | Jawa Barat |
Negara | Indonesia |
Telepon | 022 201 3789 ext. 168, 169, 239 |
Fax | 022 201 3889 |
E-mail Administrator | erlin.arvelina@polban.ac.id |
E-mail CKO | erlin.arvelina@polban.ac.id |
Print ...
Kontributor...
- Pembimbing 1: C. Bambang Dwi Kuncoro, S.T., M.T.
Pembimbing 2: Ir. Arda Rahardja Lukitobudi, Editor: Erlin Arvelina
Download...
File : DAFTAR - 111611040.pdf
(1147130 bytes)
File : BAB 1 - 111611040.pdf
(321284 bytes)
File : BAB 2 - 111611040.pdf
(838460 bytes)
File : BAB 5 - 111611040.pdf
(254362 bytes)