Pengaruh Penggunaan Liquid Suction Heat Exchanger Terhadap Kinerja Ac Split Yang Menggunakan Refrigeran Hidrokarbon (R290)

The Effects of The Use of LSHX on The Performance of Split AC with HC Refrigerant (R290)

Tugas Akhir, 024 / 2016 / RTU
Undergraduate Theses from JBPTPPOLBAN / 2017-09-04 10:20:45
Oleh : Anisa Haniah Masturoh - 131611035 (anisa.haniah1@gmail.com)
Dibuat : 2017-09-04, dengan 4 file

Keyword : Effects of The Use of LSHX, Performance of Split AC, HC Refrigerant (R290)
Subjek : Penggunaan Liquid Suction Heat Exchanger, Kinerja Ac Split , Refrigeran Hidrokarbon (R290)

AC Split digunakan untuk mendinginkan suatu ruangan sesuai dengan temperatur yang diinginkan. Tujuan penelitian dari Tugas Akhir ini adalah untuk menganalisis pengaruh penggunaan LSHX terhadap kinerja AC Split yang menggunakan refrigeran hidrokarbon. Kinerja AC Split dapat ditingkatkan, salah satunya adalah dengan cara menggunakan Liquid Suction Heat Exchanger, di mana sisi dingin (suction line) dari sistem dapat dimanfaatkan untuk menyerap kalor dari sisi panas (liquid line) sehingga subcooled yang dihasilkan pun akan meningkat dan diharapkan mampu meningkatkan efek refrigerasinya. Refrigeran yang digunakan pada penelitian ini adalah refrigeran R-290 sebagai refrigeran primernya. Penelitian ini dilakukan dengan cara membandingkan performansi antara sistem AC Split yang menggunakan LSHX dan sistem AC Split tanpa menggunakan LSHX. Analisis dilakukan dengan mengambil data tekanan discharge, tekanan suction, temperatur discharge, temperatur suction, temperatur masuk kapiler, temperatur masuk dan keluar suction heat exchanger dan liquid heat exchanger, Tdb dan Twb udara suplai, Tdb dan Twb udara return, serta arus, tegangan, dan daya listrik. Dari analisis tersebut dapat diperoleh bahwa sistem AC Split yang menggunakan LSHX lebih efisien dan cenderung lebih hemat energi dibandingkan dengan sistem AC Split tanpa menggunakan LSHX dengan nilai arus listrik rata-rata sebesar 2,61 ampere, daya listrik 461,74 Watt, COPa 7,50, efisiensi sistem 86% , dan kapasitas pendinginan koil sebesar 0,873 kW, serta EER sebesar 6,45 Btuh/W. Sedangkan untuk sistem tanpa penggunaan LSHX memiliki nilai arus rata-rata sebesar 2,62 ampere, daya listrik 464,44 Watt, COPa 5,5, efisiensi sistem 70%, dan kapasitas pendinginan koil sebesar 0,845, serta EER sebesar 6,23 Btuh/W.

Deskripsi Alternatif :

Split AC was used for cooling a room as a necessary. The purpose of this final project research is to analysis the effects of the use of LSHX on the performance of Split AC. The performance of Split AC can be improved by using Liquid Suction Heat Exchanger, where cooling side (suction line) of a system can be used for absorbing a heat from heating side (liquid line), so subcooled that is resulted will be increase and hoped the effect of refrigeration can be increased. The refrigerant that is used for this research is hydrocarbon grade propane as a primer refrigerant. This research was done by comparing a performance between Split AC system with LSHX and Split AC system without LSHX. The analysis was done by taking data such as the discharge pressure, suction pressure, discharge temperature, suction temperature, capiller in temperature, in and out suction heat exchanger and liquid heat exchanger temperature, Tdb and Twb supply air, Tdb and Twb return air, current, voltage, and electrical energy. From the analysis, the result’s obtained that energy and efficiency Split AC system with LSHX is better than Split AC system without LSHX, with current of 2,61 ampere, electricity energy 461,74 Watt, COPa 7,02, system efficiency 86%, cooling coil capacity 0,873 kW, and EER 6,45 [(Btu/h)/W]. While Split AC system without LSHX has a current of 2,62 ampere, electricity energy 464,44 Watt, COPa 5,5, efficiency system 70%, and cooling coil capacity 0,845, with EER 6,23 Btuh/W.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakErlin Arvelina
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorerlin.arvelina@polban.ac.id
E-mail CKOerlin.arvelina@polban.ac.id

Print ...

Kontributor...

  • Pembimbing : M. Nuryadi, ST., M.Eng ; A.P. Edi Sukamto, ST., MT, Editor: Muhammad Abdillah Islamy, S.Pd

Download...