Gangguan fasa merupakan gangguan yang seringkali terjadi akibat adanya kesalahan teknis, polusi debu, dan pengaruh alam di sekitar jaringan tenaga listrik. Gangguan fasa menyebabkan adanya arus yang mengalir antar fasa yang menyebabkan terjadinya over current (arus lebih) yang dapat membahayakan sistem jaringan. Untuk mengatasi persoalan tersebut, sebelum dilakukan pemisahan bagian yang terganggu oleh pemutus tenaga (CB) pada jaringan, besaran gangguan harus dapat terdeteksi oleh rele arus lebih. Rele arus lebih merupakan komponen proteksi yang dapat memonitor gangguan dan pada saat yang sama memberikan sinyal pada tripping coil untuk menarik pemutus tenaga (CB). Perlu adanya pengujian yang meliputi pengujian karakteristik dari rele arus lebih yang digunakan dan pengujian fungsi kerja rele arus lebih sehingga penggunaan rele arus lebih tepat sasaran. Pada proyek akhir dilakukan rancang bangun simulator alat uji rele arus lebih yang bertujuan untuk mengetahui karakteristik rele arus lebih dan fungsi kerja rele MCGG 53 dan MCGG 82 sebagai komponen proteksi yang saling berkoordinasi dengan komponen proteksi lainnya. Simulator ini dioperasikan untuk mengetahui karakteristik dan menguji koordinasi rele MCGG 53 dan MCGG 82 yang hasilnya akan dianalisa untuk menentukan parameter kelayakan simulator alat uji yang dibuat. Simulator ini dapat bekerja dengan rata-rata kesalahan (Error) keseluruhan = 3,91% dibawah standard yang tertera pada manual book MCGG. Penggunaan simulator alat uji ini diharapkan dapat memudahkan proses pengujian rele arus lebih dan diharapkan pula adanya pengembangan baik dalam segi kinerja alat dan penggunaan komponen instrumen yang lebih andal. Kata Kunci: Simulator alat uji, Rele arus lebih, Gangguan Fasa, Karakteristik rele, Koordinasi Rele, Sistem proteksi.
Deskripsi Alternatif :Phase Fault is fault that often happens due to a technical error, pollution dust, and the influence of nature in the vicinity of electric power network. Phase Fault causes the current that flows between the phase that led toover current (the current more) that may harm the network system. To resolve the issue, prior to the separation section that bothered by the circuit breaker (CB) on the network, the magnitude of disruption should be detected by over current relay. Over Current Relay is more of a protection component can monitor interference and at the same time give a signal on tripping coil to pull circuit breaker (CB). Need a testing that includes testing the characteristics of the Over Current Relay that used and testing work function Over Current Relay so the use of over current relay aymore precisely on target. In Final Project done architecture simulator of over Current Relay that aims to find out the characteristics and functions of Over Current Relay and work function of relay MCGG 53 and MCGG 82 as a mutual protection components coordinate with other protection components. This Simulator is operated to determine characteristics and test coordination relay MCGG 53 and MCGG 82 whose results will be analyzed to determine the feasibility of a simulator test equipment parameters are made. This Simulator can work with average error (Error) = 3,91% overall under the standard provided in the manual book MCGG. The use of a simulator test equipment is expected to simplify the process of testing the Over Current Relay and hopefully also the existence of good performance in terms of development tools and the use of more reliable instrument components. Keywords: Simulator test equipment, Overcurrent relay, disorder, Phase, characteristics Relay, coordination, protection system.
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | JBPTPPOLBAN |
Organisasi | |
Nama Kontak | Erlin Arvelina |
Alamat | Jl. Trsn. Gegerkalong Hilir Ds. Ciwaruga |
Kota | Bandung |
Daerah | Jawa Barat |
Negara | Indonesia |
Telepon | 022 201 3789 ext. 168, 169, 239 |
Fax | 022 201 3889 |
E-mail Administrator | erlin.arvelina@polban.ac.id |
E-mail CKO | erlin.arvelina@polban.ac.id |
Print ...
Kontributor...
- Pembimbing 1: Supriyanto, S.T., M.T.
Pembimbing 2: Drs. Dwi Asmono, M.Pd., Editor: Erlin Arvelina
Download...
File : JURNAL - 111321007.pdf
(732057 bytes)