Path: Top > Tugas Akhir - D3 > Jurusan Teknik Refrigerasi dan Tata Udara > Program Studi Teknik Refrigerasi dan Tata Udara > 2013
Perancangan Sistem Tata Udara Ruang Bersih (Clean Room) untuk Laboratorium Pengujian Produk Farmasi
Design of Clean Room Air Conditioning System for Pharmaceutical Product Testing Laboratory
Tugas Akhir, 008 / 2013 / RTUUndergraduate Theses from JBPTPPOLBAN / 2017-04-10 15:52:43
Oleh : Anita Nurhalimah - 101611037 (anita.nurhalimah6@gmail.com)
Dibuat : 2017-04-10, dengan 4 file
Keyword : Sistem Tata Udara, Ruang Bersih, dan Pengujian Produk Farmasi
Subjek : Air Conditioning System, Clean Room, and Testing pharmaceutical product
Proses pengujian produk farmasi dalam bentuk tablet harus dalam keadaan steril agar produk tidak terkontaminasi oleh bakteri atau virus berbahaya. Untuk mencegah hal tersebut, ruangan pengujian harus dikondisikan dengan temperatur, kelembaban dan tekanan udara ruangan tertentu, sehingga dibutuhkan sistem tata udara untuk proses pengkondisian ruang bersih (Clean Room). Sistem tata udara ruang bersih yang dirancang dipergunakan untuk labotarorium pengujian produk farmasi yang terdiri dari laminer room, clean room, anteroom1, dress room dan anteroom2 dengan total ukuran ruangan 5,4 m x 1,6 m. Temperatur rancangan 22°C dengan RH 55% sedangkan temperatur lingkungan 33°C dengan RH 70%. Perhitungan beban pendinginan menggunakan metode CLF dan CLTD ASHRAE GRP 158. Beban total pendinginan sebesar 6,2 kW maka Package Unit yang dipilih tipe RD-25FB dari FUJI ELECTRIC dan beban reheat sebesar 0,3 kW menggunakan duct heater tipe QUA slip-in and QUZ Flanged Heater kapasitas 1 kW dari INDEECO. Ruang bersih yang dirancang menggunakan pre-filter F8, medium filter G4, dan final filter H13 dan H14. Saluran udara menuju ruang laminer mempunyai drop tekanan 1347 Pa dengan debit 14,8 L/s dan anteroom 2 mempunyai drop tekanan 1177 Pa dengan debit 22,5 L/s , maka diperoleh tipe fan RNJ up to 1750 Pa dari JANKA dengan power input 1,1 kW. Drop tekanan untuk saluran ekshaust sebesar 555 Pa dengan debit 83,2 L/s dan saluran udara segar sebesar 686 Pa dengan debit 80,5 L/s sehingga fan yang dipilih tipe RNH up to 710 Pa dari JANKA dengan power input 1,1 kW. . Kata Kunci: Sistem Tata Udara, Ruang Bersih, dan Pengujian Produk Farmasi.
Deskripsi Alternatif :The process of testing pharmaceutical products in tablet form in order to be in a state of sterile products are not contaminated by harmful bacteria or viruses. To prevent this, the test shall be conditioned room with temperature, humidity and air pressure of a particular room, so it is necessary for the system of air conditioning is a clean (Clean Room). Clean room air conditioning system is designed for pharmaceutical product laboratorium testing consist of laminar room, clean room, anteroom 1, dress room, and anteroom 2 with total room size 5,4 m x 1,6 m. Temperatur design was 22°C and 55% RH while the ambient temperature 33°C with 70% RH. Cooling load calculation was done by CLF and CLTD ASHRAE GRP 185 method. The total cooling load amount is 6,2 kW then selected type of Package Unit is RD-25FB type from Fuji Electric. Reheat load amount is 0,3 kW using a Duct Heater QUA slip-in type and QUZ Flanged Heater with capacity around 1 kW from INDEECO. The clean room was designed using a F8 pre-filter, G4 medium filter, and the H13 and H14 final filter. Laminar air duct leads to the room has 1347 Pa pressure drop at the rate 14,8 L/s and 2 have anteroom 1177 Pa pressure drop at the rate of 22,5 L/s the obtained RNJ fan type up to 1750 Pa JANKA with a power input of 1,1 kW . The pressure drop of 555 Pa exshaust channel to rate of flow 83,2 L/s and the fresh air duct at 686 Pa with a rate of flow 80,5 L/s the obtained RNH fan type up to 710 Pa of JANKA with a power input of 1,1 kW. Keywords: Air Conditioning System, Clean Room, and Testing pharmaceutical product.
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | JBPTPPOLBAN |
Organisasi | |
Nama Kontak | Erlin Arvelina |
Alamat | Jl. Trsn. Gegerkalong Hilir Ds. Ciwaruga |
Kota | Bandung |
Daerah | Jawa Barat |
Negara | Indonesia |
Telepon | 022 201 3789 ext. 168, 169, 239 |
Fax | 022 201 3889 |
E-mail Administrator | erlin.arvelina@polban.ac.id |
E-mail CKO | erlin.arvelina@polban.ac.id |
Print ...
Kontributor...
- Pembimbing 1: Drs. Faldian, M.Eng.
Pembimbing 2: Taufik Akbar, Editor: Erlin Arvelina
Download...
File : DAFTAR - 101611037.pdf
(506979 bytes)
File : BAB 1 - 101611037.pdf
(184516 bytes)
File : BAB 2 - 101611037.pdf
(684718 bytes)
File : BAB 5 - 101611037.pdf
(634028 bytes)