Pembandingan Metode Penentuan Total Acid Number dalam Solar dan biodisel secara Potensiometri dan Volumetri

Comparison method of Total acid number in solar and biodiesel by potensiometri and volumetri

Tugas Akhir, 019 / 2013 / ANK
Undergraduate Theses from JBPTPPOLBAN / 2017-04-10 11:32:23
Oleh : Annisa Nur Auliani - 101431003 (annisaanaliskimia@yahoo.co.id)
Dibuat : 2017-04-10, dengan 4 file

Keyword : Total Acid Number, Potensiometri dan Volumetri
Subjek : Total Acid Number, Potentiometric and Volumetric

Solar dan biodiesel merupakan produk petroleum yang memiliki kandungan asam, jika kandungan asam tersebutmelebihi batas maksimum maka akan menurunkan nilai mutu produk dan berdampak korosif pada mesin.Untuk itu perlu dilakukan pengujian kandungan asam total dalam produk petroleumdengan Total acid number metode volumetri (ASTM D974)dan metode potensiometri (ASTM D664).Pengujian terhadap kedua metode tersebut dilakukan dengan Uji T-berpasangan untuk melihat perbedaan secara nyata dan uji-F untuk melihat galat acak diantara kedua metode tersebut.Hasil uji T-berpasangan dan uji-F menunjukkan bahwaH0 diterima.Hasil tersebut menunjukkan bahwa kedua metode tersebut tidak berbeda secara nyata dan tidak terdapat galat acak. Berdasarkan hasil uji T-berpasangan dan uji-F dapat disimpulkan bahwa metode potensiometri dan volumetri dapat digunakan untuk penentuan Total Acid Number. Kata kunci: Total Acid Number, Potensiometri dan Volumetri.

Deskripsi Alternatif :

Diesel and biodiesel are a petroleum product that contains acid, if the acid content exceeds the maximum limit it will lower the value of the product quality and corrosive effect on engines. It is necessary for testing the total acid content in petroleum products with total acid number volumetric method (ASTM D974) and a potentiometric method (ASTM D664). Tests on both methods performed by paired T-test to see the difference in real and test-F to see a random error between the two methods. Results of paired T-test and F-test shows that H0 is accepted. The results showed that the two methods aren't significantly different and there is no random error. Based on the results of paired T-test and F-test can be concluded that the potentiometric and volumetric methods can be used for the determination of Total Acid Number. Keywords: Total Acid Number, Potentiometric and Volumetric

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakErlin Arvelina
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorerlin.arvelina@polban.ac.id
E-mail CKOerlin.arvelina@polban.ac.id

Print ...

Kontributor...

  • Pembimbing 1: Dra. Ari Marlina, M.Si.

    Pembimbing Lapangan: Dwi Hariyanto, S.Si., Editor: Erlin Arvelina

Download...